• 제목/요약/키워드: concrete capacity design

검색결과 1,070건 처리시간 0.172초

무량복합 및 벽식 구조시스템의 내진성능평가 (Seismic Performance Evaluation of Flat Column Dry Wall System and Wall Slab System Structures)

  • 강현구;이민희;김진구
    • 한국전산구조공학회논문집
    • /
    • 제25권3호
    • /
    • pp.259-266
    • /
    • 2012
  • 본 논문에서는 벽식 구조시스템의 일부 전단벽을 제거하여 공간의 가변성을 높인 무량복합 구조시스템의 내진성능을 ATC-63에 제시되어 있는 절차에 따라 파악하였으며, 동일한 규모의 벽식 구조시스템의 내진성능과 비교하였다. 해석모델로 12층 무량복합 및 벽식 구조시스템을 KBC 2009에 따라 설계하고 비선형 정적 및 비선형 증분 동적해석(IDA)을 수행하여 지진응답 및 붕괴거동을 파악하였다. 무량복합 시스템은 벽식 구조시스템 보다 적은 양의 콘크리트 물량으로 설계되었으며, 동일한 지진하중에 대하여 좀 더 큰 변위응답을 보이는 것으로 나타났다. IDA 해석결과 얻어진 붕괴 여유비(CMR)는 ATC-63에 제시된 한계상태를 만족하여 설계지진하중에 대하여 충분한 내진성능을 보유한 것으로 나타났다.

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

거푸집 설치 방법에 따른 철도 전철주기초의 모멘트 저항 거동 (Moment Resisting Behaviors of Railway Electric Pole Foundation According to Form Work Methods)

  • 이수형;이승현
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.411-417
    • /
    • 2013
  • 철도선로에 설치되는 전철주기초의 모멘트에 대한 거동을 파악하기 위한 실물 재하시험을 수행하였다. 현장타설방식으로 설치된 폭 1.1m, 깊이 2.2m의 정사각형 전철주기초 2본에 대하여 실제 조건과 동일한 모멘트 위주의 하중을 가하여 기초의 항복모멘트를 확인하였다. 거푸집 설치 여부가 기초의 저항모멘트에 미치는 영향을 평가하기 위하여 동일한 조건에서 거푸집을 설치한 경우와 그렇지 않은 경우에 대하여 시험하였다. 거푸집 설치 효과로 흙과 지반의 접촉면이 매끈해지면서 발생하는 마찰력 감소보다는, 거푸집 미설치 시 굴착지반의 이완에 의한 기초 주변지반의 강도 감소 효과가 더 크게 나타나는 것으로 나타났다. 비례계수를 사용하여 포괄적으로 전철주기초의 저항모멘트를 산정하는 현행 설계방법으로는 거푸집의 설치효과를 적절히 고려할 수 없었으며, 연직응력과 마찰력을 분리하여 저항모멘트를 산정하는 경우에는 기초와 지반의 마찰각을 20% 감소시킴으로써 거푸집 설치효과에 대한 합리적인 고려가 가능하였다.

Validation of the seismic response of an RC frame building with masonry infill walls - The case of the 2017 Mexico earthquake

  • Albornoz, Tania C.;Massone, Leonardo M.;Carrillo, Julian;Hernandez, Francisco;Alberto, Yolanda
    • Advances in Computational Design
    • /
    • 제7권3호
    • /
    • pp.229-251
    • /
    • 2022
  • In 2017, an intraplate earthquake of Mw 7.1 occurred 120 km from Mexico City (CDMX). Most collapsed structural buildings stroked by the earthquake were flat slab systems joined to reinforced concrete (RC) columns, unreinforced masonry, confined masonry, and dual systems. This article presents the simulated response of an actual six-story RC frame building with masonry infill walls that did not collapse during the 2017 earthquake. It has a structural system similar to that of many of the collapsed buildings and is located in a high seismic amplification zone. Five 3D numerical models were used in the study to model the seismic response of the building. The building dynamic properties were identified using an ambient vibration test (AVT), enabling validation of the building's finite element models. Several assumptions were made to calibrate the numerical model to the properties identified from the AVT, such as the presence of adjacent buildings, variations in masonry properties, soil-foundation-structure interaction, and the contribution of non-structural elements. The results showed that the infill masonry wall would act as a compression strut and crack along the transverse direction because the shear stresses in the original model (0.85 MPa) exceeded the shear strength (0.38 MPa). In compression, the strut presents lower stresses (3.42 MPa) well below its capacity (6.8 MPa). Although the non-structural elements were not considered to be part of the lateral resistant system, the results showed that these elements could contribute by resisting part of the base shear force, reaching a force of 82 kN.

사장교의 내풍해석을 통한 인명보호 구조물의 내하능력평가 (Load-carrying Capacities of Safety Structures on Wind-resistant Analyses of Cable-stayed Bridge)

  • 허택녕
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.587-594
    • /
    • 2022
  • In the 2000s, a lot of cable-type grand bridges are being built in consideration of economic aspects such as the reduction of logistics costs and the distribution of traffic volume due to rapid economic development. In addition, because the recently installed grand bridges are designed in an aesthetic form that matches the surrounding environment as well as the original function of the road bridge, and serves as a milestone in an area and is used as an excellent tourism resource, attracting many vehicles and people, there is an urgent need for a safety structure that can ensure the safety of not only vehicles but also people. In order to make cable-stayed bridge safe on wind for additional five safety structures, main girder models with and without safety structures for wind-tunnel experiments was made, and wind tunnel experiments was carried out to measure aerodynamic force coefficients. Also, wind-resistant analyses of 3D cable-stayed bridge were performed on the basis of wind-tunnel experiment results. From the wind tunnel experiments for the aerodynamic force coefficients of main girder with five safety structures and the wind resistant analyses of cable-stayed bridge without safety structure and with safety structure, it was concluded that the best form of wind-resistant safety was shown in the order of mesh, standard, bracing, hollow, and closed type. And wind-resistant safety of cable-stayed bridge with hollow and closed type on design wind speed 68.0m/sec was not secured. Finally, as five safety structures are installed, maximum rate of stress increments was shown in the order of steel main beam, steel floor beam, concrete floor beam and cables.

Stochastic fracture behavior analysis of infinite plates with a separate crack and a hole under tensile loading

  • Khubi Lal Khatri;Kanif Markad
    • Computers and Concrete
    • /
    • 제32권1호
    • /
    • pp.99-117
    • /
    • 2023
  • The crack under the influence of the higher intensities of the stresses grows and the structure gets collapsed with the time when the crack length reaches to critical value. Therefore, the fracture behavior of a structure in terms of stress intensity factors (SIF) becomes important to determine the remaining fracture strength and capacity of material and structure for avoiding catastrophic failure, increasing safety and further improvement in the design. The robustness of the method has been demonstrated by comparing the numerical results with analytical and experimental results of some problems. XFEM is used to model cracks and holes in structures and predict their strength and reliability under service conditions. Further, XFEM is extended with a stochastic method for predicting the sensitivity in terms of output COVs and fracture strength in terms of mean values of stress intensity factors (SIFs) of a structure with discontinuities (cracks and holes) under tensile loading condition with input individual and combined randomness in different system parameters. In stochastic technique, the second order perturbation technique (SOPT) has been used for the predicting the fracture behavior of the structures. The stochastic/perturbation technique is also known as Taylor series expansion method and it provides the reliable results if the input randomness is less than twenty percentage. From the present numerical analysis it is observed that, the crack tip near to the hole is under the influence of the stress concentration and the variational effect of the input random parameters on the crack tip in terms of the SIFs are lesser so the COVs are the less sensitive. The COVs of mixed mode SIFs are the most sensitive for the crack angles (α=45° to 90°) for all the values of c1 and d1. The plate with the shorter distance between hole and crack is the most sensitive with all the crack angles but the crack tip which is much nearer to the hole has the highest sensitivity.

학교 건축물의 면내보강을 위한 강재브레이스 접합용 내진어댑터의 상세 제안 및 성능검증 (Proposal and Performance Verification of a Seismic Adapter for Steel Brace Connections for In-plane Reinforcement of School Buildings)

  • 허석재;정란;백인관
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.162-171
    • /
    • 2023
  • 본 연구에서는 기존 구조물의 면내 보강을 위해 콘크리트 구조물과 보강재를 쉽게 연결할 수 있는 내진 어댑터의 세부 설계 방안을 제안하였다. 제안된 내진 어댑터는 실제 크기의 절반으로 축소된 2층짜리 기둥-보 구조물에서 동적 시뮬레이션을 통해 성능을 테스트하였다. 실험 결과, 내진 어댑터를 사용하여 보강된 시험체는 보강되지 않은 시험체에 비해 에너지 소산 능력이 3.5배 향상되었음을 보여주어, 일반적인 사용 범위 내에서 내진 어댑터가 손상되지 않았음이 확인되어 그 효과를 입증하였다. 이어서 변형 한계(변형 각도 3.3%)까지 하중을 가했을 때, 1층 하부에서 어댑터와 보강재를 연결하는 M10 볼트 중 하나가 파손된 것을 관찰하였다. 이러한 발견을 고려할 때, 실제 상황에서 내진 보강을 적용할 때는 내진 어댑터를 연결하는 볼트와 앵커의 설계에 중점을 둬야 할 것으로 판단되었다.

PSSC 합성거더 교량의 비선형 거동 분석 및 신뢰도 해석 (Analysis of Nonlinear Behavior and Reliability of PSSC Composite Girder Bridge)

  • 황철성;백인열
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.158-166
    • /
    • 2008
  • 프리스트레스하중이 작용되는 강합성교인 PSSC 교량에서 프리스트레스의 효과와 단면의 변형에 따른 텐돈의 변형의 영향을 밝히기 위해 사하중 및 활하중이 작용될 때 합성전 후에 발생하는 부재내의 변형도 및 응력변화와 허용응력 한계상태, 항복응력 한계상태 및 강도한계상태의 단면력과 부재내의 변형도 및 응력변화를 구한다. 또한 거더의 처짐 및 응력과 휨강도를 변수로 하는 한계상태들을 가정하고 이에 대한 신뢰도 분석을 수행한다. 허용응력에 맞추어 설계한 예제 단면의 응력에 대한 신뢰도 지수가 0 부근임에 비하여, 처짐 및 휨강도에 대한 신뢰도 지수는 높은 값을 주고 있어서 도로교설계기준의 허용응력에 대하여 설계한 PSSC 거더는 처짐 및 휨강도에 대하여 높은 신뢰도를 얻을 수 있음을 알 수 있다.

하중조합과 충전층 두께에 따른 3차원 유한요소 해석에 의한 PST 부재의 거동 분석 (PST Member Behavior Analysis Based on Three-Dimensional Finite Element Analysis According to Load Combination and Thickness of Grouting Layer)

  • 서현수;김진섭;권민호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.53-62
    • /
    • 2018
  • 국내뿐만 아니라 세계적인 추세로 증가하고 있는 열차의 고속화와 대량 운송능력의 요구에 따라 열차 궤도구조의 개발은 지속적으로 발전하고 있다. 콘크리트 구조궤도인 PST는 안전성과 경제성에서 그 요구조건을 충족할 수 있는 시스템으로 개발되고 있다. 따라서 본 연구에서는 PST시스템의 각 구조부재의 거동을 분석함으로써 향후 시스템 개발 및 설계에 필요한 정보를 제공하고자 하였다. KRL-2012 열차하중과 KRC 코드에 의한 다양한 정적하중조합에 따른 응력분포 결과를 3차원 유한요소 해석을 통하여 분석하였으며, 그라우트충전층의 두께에 따른 결과 또한 제공하고자 하였다. 구조부재별로는 그라우트충전층에서 가장 큰 응력이 발생하였으며 하중조합과 두께에 따라 응력의 변화가 민감하였다. 시동하중 및 온도하중에 의해서는 KRL-2012에 의한 수직하중만 적용할 때와 비교하여 콘크리트 패널과 HSB에서 각각 3.3배, 14.1배의 발생응력이 증가하는 것으로 나타났다. 충전층의 두께가 20mm에서 80mm로 증가할 때 콘크리트 패널의 발생 응력은 4% 감소하지만, 충전층은 24% 증가하는 것으로 나타났다. 균열의 양상은 그라우트충전층에서 인장균열이 국부적으로 발생하는 것으로 나타났다. 이와같은 결과에 따라 PST시스템 개발 시에는 수직하중 보다는 수평하중에 의한 휨 및 인장거동에 세심한 주의가 필요하며, 충전층의 두께를 40mm 이상 유지함으로써 각 구조부재의 안전성을 확보할 수 있도록 한다.

중공 전이 슬래브의 뚫림 전단 강도 (Punching Shear Strength of the Void Transfer Plate)

  • 한상환;박진아;김준삼;임주혁;박영미
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.367-374
    • /
    • 2010
  • 전이슬래브 시스템은 상부 전단벽 구조로부터 하부 기둥으로 하중을 전달하는 구조시스템이다. 이 시스템은 상당한 두께의 슬래브를 필요로 하므로 비경제적이며, 이 단점은 슬래브내에 중공부를 두어 해결할 수 있다. 그리고 이 시스템은 플랫플레이트 구조로써 기둥-슬래브 접합부 부근의 뚫림전단파괴을 일으키는 취성파괴의 위험이 존재한다. 따라서 중공부를 갖는 전이슬래브 시스템의 뚫림전단 성능은 매우 중요하다. 그러나 현행 기준에서는 중공부를 갖는 슬래브의 뚫림전단성능에 대한 명확한 강도산정 규정이 제시되어 있지 않다. 이 연구에서는 중공 시스템의 뚫림전단강도를 알아보기 위하여 실험적 연구를 수행하였으며, 현행기준 및 기존연구를 토대로 실험체의 전단강도를 예측하였다. 그 결과, 중공시스템의 뚫림전단강도는 기둥면으로부터 위험단면 d/2의 위치와 중공부 중심에서의 위험단면으로 계산된 값 중 작은 값으로 결정되었다. 여기서 강도 계산을 위하여 위험단면의 유효단면적을 사용하여 계산하였다.