DOI QR코드

DOI QR Code

Proposal and Performance Verification of a Seismic Adapter for Steel Brace Connections for In-plane Reinforcement of School Buildings

학교 건축물의 면내보강을 위한 강재브레이스 접합용 내진어댑터의 상세 제안 및 성능검증

  • 허석재 (단국대학교 리모델링연구소) ;
  • 정란 (단국대학교 건축학부) ;
  • 백인관 (단국대학교 리모델링연구소)
  • Received : 2023.10.27
  • Accepted : 2023.12.08
  • Published : 2023.12.31

Abstract

In this study, The details for a seismic adapter designed to easily connect concrete structures and reinforcement materials for the in-plane reinforcement of aged structures were proposed. Proposed seismic adapter was tested for performance using a dynamic simulation on a 2-story column-beam structure, scaled to half of the real size. The experimental results showed that the reinforced test specimens using the seismic adapter improved their energy dissipation capacity by 3.5 times compared to the non-reinforced specimens. It was confirmed that the seismic adapter experienced no damage within its general usage range, thus proving its effectiveness. Subsequently, upon loading until the limit of deformation (a deformation angle of 3.3%), it was observed that one of the M10 bolts connecting the adapter and the reinforcement at the lower part of the first floor broke. Considering this finding, when applying seismic retrofitting in real situations, emphasis should be placed on the design of the bolts and anchors connecting the seismic adapter. This aspect warrants further research for validation.

본 연구에서는 기존 구조물의 면내 보강을 위해 콘크리트 구조물과 보강재를 쉽게 연결할 수 있는 내진 어댑터의 세부 설계 방안을 제안하였다. 제안된 내진 어댑터는 실제 크기의 절반으로 축소된 2층짜리 기둥-보 구조물에서 동적 시뮬레이션을 통해 성능을 테스트하였다. 실험 결과, 내진 어댑터를 사용하여 보강된 시험체는 보강되지 않은 시험체에 비해 에너지 소산 능력이 3.5배 향상되었음을 보여주어, 일반적인 사용 범위 내에서 내진 어댑터가 손상되지 않았음이 확인되어 그 효과를 입증하였다. 이어서 변형 한계(변형 각도 3.3%)까지 하중을 가했을 때, 1층 하부에서 어댑터와 보강재를 연결하는 M10 볼트 중 하나가 파손된 것을 관찰하였다. 이러한 발견을 고려할 때, 실제 상황에서 내진 보강을 적용할 때는 내진 어댑터를 연결하는 볼트와 앵커의 설계에 중점을 둬야 할 것으로 판단되었다.

Keywords

Acknowledgement

본 연구는 한국연구재단 창의도전지원사업(과제번호: 2021R1I1A1A0104962413)와 중점연구소지원사업(과제번호: 2018R1A6A1A07025819) 의 지원에 의해 수행되었습니다.

References

  1. Kim, S. H., Jung, W. T., Kang, J. Y., Park, H. B., and Park, J. S. (2021), Experimental Study on the Strengthening Effect of External Prestressing Method Considering Deterioration, Journal of the Korea Institute for Structural Maintenance and Inspection, 25(1), 1-6 (in Korean). https://doi.org/10.3390/app11062553
  2. Lee, B. G., Hwang, D. S., Choi, Y. C., Kim, Y. S., and Lee, K. S. (2019), Seismic Capacity Evaluation of Full-size Two-story R/C Frame Strengthened with HSWF External Connection Method by Pseudo-dynamic Test, Journal of the Korea Concrete Institute, 31(1), 89-97 (in Korean). https://doi.org/10.4334/JKCI.2019.31.1.089
  3. Lee, K. S., Jung, J. S., and Lee, J. K. (2015), Seismic Performance Evaluation of Seismic Strengthening Method using SRCF External Connection of Medium and Low-rise R/C Buildings, Journal of the Korea Concrete Institute, 27(2), 147-155 (in Korean). https://doi.org/10.4334/JKCI.2015.27.2.147
  4. Lee, K. S. (2016), Damage Analysis of School Facilities due to the 2016 Gyeongju Earthquake and Seismic Measures for Non-Seismic School Facilities, Proceedings of the Fall Academic Conference of the Korean Institute of educational Facilities, 21-81 (in Korean).
  5. Oh, S. H. (2016), Direction of Seismic Retrofitting Methods and System Improvements through Case Studies of Seismic Retrofitting of School Facilities, Proceedings of the Fall Academic Conference of the Korean Institute of Educational Facilities, 12, 85-118 (in Korean).
  6. Ryu, H. G., Lee, S. H., Chung, R., and Park, T. W. (2008), Seismic Performance Evaluation of School Buildings Considering the Short-Column Effect, Proceedings of the Academic Presentation Conference of the Korea Institute for Structural Maintenance and Inspection, 12(2), 55-60 (in Korean).
  7. Kim, H. J., Woo, S. S., Lee, S. H., and Chung, R. (2008), Seismic Performance Evaluation of School Buildings Using Response Spectrum Method and Non-linear Static Analysis, Proceedings of the Academic Presentation Conference of the Korea Institute for Structural Maintenance and Inspection, 12(2), 61-66 (in Korean).
  8. Ryu, H. K., Park, T. W., Lee, S. H., Chung, R., and Jo, S. H. (2009), Seismic Performance Evaluation of School Buildings in Gyeonggi Region Considering Detailed Disaster Maps, Journal of the Korean Society of Safety, 24(4), 66-73 (in Korean).
  9. Hur, M. W., Chae, K. H., Won, J. S., and Park, T. W. (2021), Evaluation of Design Equations for Post-Installed Anchors Considering Effective Embedment Depth and Concrete Strength, Journal of the Korea Institute for Structural Maintenance and Inspection, 25(3), 13-20 (in Korean).