• 제목/요약/키워드: computed tomography image

검색결과 966건 처리시간 0.026초

Prognostic Implication of Volumetric Quantitative CT Analysis in Patients with COVID-19: A Multicenter Study in Daegu, Korea

  • Byunggeon Park;Jongmin Park;Jae-Kwang Lim;Kyung Min Shin;Jaehee Lee;Hyewon Seo;Yong Hoon Lee;Jun Heo;Won Kee, Lee;Jin Young Kim;Ki Beom Kim;Sungjun Moon;Sooyoung, Choi
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1256-1264
    • /
    • 2020
  • Objective: Lung segmentation using volumetric quantitative computed tomography (CT) analysis may help predict outcomes of patients with coronavirus disease (COVID-19). The aim of this study was to investigate the relationship between CT volumetric quantitative analysis and prognosis in patients with COVID-19. Materials and Methods: CT images from patients diagnosed with COVID-19 from February 18 to April 15, 2020 were retrospectively analyzed. CT with a negative finding, failure of quantitative analysis, or poor image quality was excluded. CT volumetric quantitative analysis was performed by automated volumetric methods. Patients were stratified into two risk groups according to CURB-65: mild (score of 0-1) and severe (2-5) pneumonia. Outcomes were evaluated according to the critical event-free survival (CEFS). The critical events were defined as mechanical ventilator care, ICU admission, or death. Multivariable Cox proportional hazards analyses were used to evaluate the relationship between the variables and prognosis. Results: Eighty-two patients (mean age, 63.1 ± 14.5 years; 42 females) were included. In the total cohort, male sex (hazard ratio [HR], 9.264; 95% confidence interval [CI], 2.021-42.457; p = 0.004), C-reactive protein (CRP) (HR, 1.080 per mg/dL; 95% CI, 1.010-1.156; p = 0.025), and COVID-affected lung proportion (CALP) (HR, 1.067 per percentage; 95% CI, 1.033-1.101; p < 0.001) were significantly associated with CEFS. CRP (HR, 1.164 per mg/dL; 95% CI, 1.006-1.347; p = 0.041) was independently associated with CEFS in the mild pneumonia group (n = 54). Normally aerated lung proportion (NALP) (HR, 0.872 per percentage; 95% CI, 0.794-0.957; p = 0.004) and NALP volume (NALPV) (HR, 1.002 per mL; 95% CI, 1.000-1.004; p = 0.019) were associated with a lower risk of critical events in the severe pneumonia group (n = 28). Conclusion: CRP in the mild pneumonia group; NALP and NALPV in the severe pneumonia group; and sex, CRP, and CALP in the total cohort were independently associated with CEFS in patients with COVID-19.

자궁경부 위형 점액샘암종의 위 전이: 증례 보고 (Gastric Metastasis from Gastric-Type Mucinous Adenocarcinoma of Uterine Cervix: A Case Report)

  • 김민혜;김경아;전이경;김정우;이종미;이창희
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.445-450
    • /
    • 2024
  • 자궁 경부암의 위 전이는 매우 드물며, 소수의 증례만이 영문 문헌에서 보고되었다. 자궁경부 위형 점액샘암종은 드문 아형의 점액샘암종이다. 위형 점액샘암종은 진행성 암에서 발견되는 공격적인 암이지만, 위로의 전이는 보고된 바 없다. 저자들은 61세 여성의 자궁경부 위형 점액샘암종이 위 날문방에 전이된 증례를 보고하며 위 전이 및 자궁경부 점액샘암종의 영상의학적 소견을 서술하고자 한다. 위 전이는 조영증강이 잘되지 않는 점막 하 종괴로 보였다. 점액샘암종은 조영증강이 잘되지 않는 침윤성 종괴로 보였다. 확산강조영상에서는 경도의 고신호강도를 보였고 겉보기확산계수 지도에서는 낮은 값을 보였다. 이 사례는 매우 드물며 진단이 어렵지만, 자궁경부암의 유형이 사람유두종바이러스 비의존 위형 점액샘암종이며 동시에 위의 점막 하 병변이 발견된 경우, 우리 사례와 유사한 패턴의 전이 가능성을 고려할 수 있다.

Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

  • Dong Wook Kim;Jiyeon Ha;Yousun Ko;Kyung Won Kim;Taeyong Park;Jeongjin Lee;Myung-Won You;Kwon-Ha Yoon;Ji Yong Park;Young Jin Kee;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.624-633
    • /
    • 2021
  • Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

Prediction of Patient Management in COVID-19 Using Deep Learning-Based Fully Automated Extraction of Cardiothoracic CT Metrics and Laboratory Findings

  • Thomas Weikert;Saikiran Rapaka;Sasa Grbic;Thomas Re;Shikha Chaganti;David J. Winkel;Constantin Anastasopoulos;Tilo Niemann;Benedikt J. Wiggli;Jens Bremerich;Raphael Twerenbold;Gregor Sommer;Dorin Comaniciu;Alexander W. Sauter
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.994-1004
    • /
    • 2021
  • Objective: To extract pulmonary and cardiovascular metrics from chest CTs of patients with coronavirus disease 2019 (COVID-19) using a fully automated deep learning-based approach and assess their potential to predict patient management. Materials and Methods: All initial chest CTs of patients who tested positive for severe acute respiratory syndrome coronavirus 2 at our emergency department between March 25 and April 25, 2020, were identified (n = 120). Three patient management groups were defined: group 1 (outpatient), group 2 (general ward), and group 3 (intensive care unit [ICU]). Multiple pulmonary and cardiovascular metrics were extracted from the chest CT images using deep learning. Additionally, six laboratory findings indicating inflammation and cellular damage were considered. Differences in CT metrics, laboratory findings, and demographics between the patient management groups were assessed. The potential of these parameters to predict patients' needs for intensive care (yes/no) was analyzed using logistic regression and receiver operating characteristic curves. Internal and external validity were assessed using 109 independent chest CT scans. Results: While demographic parameters alone (sex and age) were not sufficient to predict ICU management status, both CT metrics alone (including both pulmonary and cardiovascular metrics; area under the curve [AUC] = 0.88; 95% confidence interval [CI] = 0.79-0.97) and laboratory findings alone (C-reactive protein, lactate dehydrogenase, white blood cell count, and albumin; AUC = 0.86; 95% CI = 0.77-0.94) were good classifiers. Excellent performance was achieved by a combination of demographic parameters, CT metrics, and laboratory findings (AUC = 0.91; 95% CI = 0.85-0.98). Application of a model that combined both pulmonary CT metrics and demographic parameters on a dataset from another hospital indicated its external validity (AUC = 0.77; 95% CI = 0.66-0.88). Conclusion: Chest CT of patients with COVID-19 contains valuable information that can be accessed using automated image analysis. These metrics are useful for the prediction of patient management.

Primary Invasive Mucinous Adenocarcinoma of the Lung: Prognostic Value of CT Imaging Features Combined with Clinical Factors

  • Tingting Wang;Yang Yang;Xinyue Liu;Jiajun Deng;Junqi Wu;Likun Hou;Chunyan Wu;Yunlang She;Xiwen Sun;Dong Xie;Chang Chen
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.652-662
    • /
    • 2021
  • Objective: To investigate the association between CT imaging features and survival outcomes in patients with primary invasive mucinous adenocarcinoma (IMA). Materials and Methods: Preoperative CT image findings were consecutively evaluated in 317 patients with resected IMA from January 2011 to December 2015. The association between CT features and long-term survival were assessed by univariate analysis. The independent prognostic factors were identified by the multivariate Cox regression analyses. The survival comparison of IMA patients was investigated using the Kaplan-Meier method and propensity scores. Furthermore, the prognostic impact of CT features was assessed based on different imaging subtypes, and the results were adjusted using the Bonferroni method. Results: The median follow-up time was 52.8 months; the 5-year disease-free survival (DFS) and overall survival rates of resected IMAs were 68.5% and 77.6%, respectively. The univariate analyses of all IMA patients demonstrated that 15 CT imaging features, in addition to the clinicopathologic characteristics, significantly correlated with the recurrence or death of IMA patients. The multivariable analysis revealed that five of them, including imaging subtype (p = 0.002), spiculation (p < 0.001), tumor density (p = 0.008), air bronchogram (p < 0.001), emphysema (p < 0.001), and location (p = 0.029) were independent prognostic factors. The subgroup analysis demonstrated that pneumonic-type IMA had a significantly worse prognosis than solitary-type IMA. Moreover, for solitary-type IMAs, the most independent CT imaging biomarkers were air bronchogram and emphysema with an adjusted p value less than 0.05; for pneumonic-type IMA, the tumors with mixed consolidation and ground-glass opacity were associated with a longer DFS (adjusted p = 0.012). Conclusion: CT imaging features characteristic of IMA may provide prognostic information and individual risk assessment in addition to the recognized clinical predictors.

토모테라피를 이용한 두경부암 영상유도 방사선 치료 시 개인별 경추고정용구의 유용성 평가 (Usefulness of Customized Cervical Spine Immobilizer in Head & Neck Image-Guided Radiation Therapy with Tomotherapy®)

  • 진성은;장세욱;최정환;김민주;안승권;이상규;조정희
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.65-71
    • /
    • 2018
  • 목 적 : 두경부암 방사선 치료 시 사용되는 규격화된 기성 베개에 개인별 경추고정용구를 적용하여 개인별 경추고정용구의 유용성을 평가하고자 한다. 대상 및 방법 : 본원에서 토모테라피를 이용한 두경부암 치료 환자 중 기성 베개만을 사용한 환자와 개인별 경추고정용구를 적용한 환자 각각 20명을 대상으로 환자 당 20회 치료 시 획득한 MVCT 영상을 토모테라피 영상유도 프로그램으로 자동 보정한 영상을 바탕으로 2번 경추 최하단부부터 발쪽으로 6.7 cm까지 10분할하여 각 분할 당 경추 위치 값을 치료설계 시의 경추 위치 값과 비교하였다. 결 과 : 개인별 경추고정용구를 적용한 경우 50 mm 기준 경추만곡도 일치율은 평균 98.9 %, 최대오차 평균 12.9 mm, 1회 치료 당 평균 오차 5.8 mm, 표준편차 평균 0.59 mm로 측정되었고 개인별 경추고정용구를 적용하지 않았을 경우 경추만곡 일치율은 평균 95.9 %, 최대오차 평균 41.9 mm, 1회 치료 당 평균 오차 19.4 mm, 표준편차 평균 1.34 mm로 측정되었다. 결 론 : 두경부 암 방사선 치료 시 개인별 경추고정용구 적용이 필요할 것으로 사료된다.

  • PDF

검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가 (Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy)

  • 강영은;정우영;홍보름
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구는 기존 안내문에서 사용하고 있는 문어체의 글자와 배열, 형태 등을 시각적으로 디자인 및 재배치 함으로써 환자의 이해도 및 검사에 미치는 영향에 대해 평가 하였다. 서울아산병원 핵의학과 영상검사에서 가장 많은 비중을 차지하는 Bone Scan과 $^{201}Thallium$ Myocardium Perfusion SPECT의 Rest Scan 안내문을 개선 대상으로 선정하고, 원내 이노베이션센터와 협의하여 새롭게 디자인 하였다. 2016년 11월부터 2017년 2월은 기존의 안내문을, 2017년 3월부터 5월은 개선된 안내문을 사용하였으며, 개선 전후의 비교를 위해 해당 시기에 Bone Scan을 시행한 환자를 대상으로 안내문에 제시된 전처치 준수 및 그에 따른 영상의 질, 검사 소요시간을 측정하였고, $^{201}Thallium$ Myocardium Perfusion SPECT를 시행한 환자를 대상으로 안내문의 내용 이해에 대한 설문조사와 안내 후 재질문 하는 환자 및 질문유형, 안내문의 내용을 이행하지 않은 환자수를 분석하였다. 개선 후에는 Bone Scan은 전 처치가 미흡한 환자와 그로 인해 추가 영상이 필요한 환자가 감소하였고 평균 검사 소요시간은 안내문 개선 후 추가 영상 획득 시간의 감소로 약 2분 감소하였다. $^{201}Thallium$ Myocardium Perfusion SPECT의 경우 안내문의 내용 이해에 대한 5가지 문항에서 모두 이해도가 증가한 결과를 얻었으며, 검사 관련 재질문 하는 환자와 안내문의 내용을 이행하지 않은 환자 모두 감소하였다. 검사 안내문은 일방적이고 단순한 정보 제공이 아니라 환자 및 보호자와의 원활한 소통으로 이어지며, 영상품질과 업무 효율성을 향상시키고 나아가 검사 소요시간의 관리로 생산성 향상에도 도움을 줄 것으로 사료된다.

경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가 (Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization)

  • 구민재;이재혁;김영환;이희정;강웅래;지승우
    • 대한영상의학회지
    • /
    • 제81권1호
    • /
    • pp.166-175
    • /
    • 2020
  • 목적 간세포암의 화학색전술에 사용되는 조영제인 Ioversol 320과 Iopamidol 250을 영상 화질과 유해반응에서 차이가 있는지 비교 분석하고자 하였다. 대상과 방법 경동맥 화학색전술을 시행 받은 113명의 간세포암 환자를 대상으로 후향적으로 분석하였고, Iopamidol 250은 44명, Ioversol 320은 69명에게 주입하였다. 영상 화질은 혈관인지도 및 일치도로 평가하였다. 혈관인지도는 두 명의 영상의학과 전문의가 간동맥 혈관조영술에서 간세분엽동맥, 췌십이지장동맥, 우위동맥, 우위대망동맥이 보이는 인지도와 명확도에 따라 3단계로 점수화하였다. 일치도는 혈관조영술과 전산화단층촬영에서 발견된 간세포암 수를 비교하였다. 시술 전후 임상증상을 조사하여 조영제 유해반응을 평가하였다. 결과 혈관인지도의 평균 점수는 Iopamidol 250은 2.92점, Ioversol 320은 2.94점이었다. 일치도는 Iopamidol 250은 31명(70.5%), Ioversol 320은 46명(66.7%)이 일치했으며, 혈관인지도와 일치도는 통계적 유의한 차이가 없었다(p > 0.05). Iopamidol 250은 1명, Ioversol 320은 6명의 환자가 오심을 호소하였으며, 유해반응 빈도의 유의한 차이는 없었다(p = 0.24). 결론 간세포암 화학색전술에서 Iopamidol 250은 Ioversol 320과 영상의 화질 및 유해반응에 유의한 차이가 없이 사용될 수 있을 것으로 생각된다.

난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study (Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition)

  • 이성재;신충훈;최소영;이동형;유순미;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.73-82
    • /
    • 2022
  • 목 적: 본 연구는 난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 HalcyonTM Fast kV CBCT를 사용하였을 때 난소에 미치는 흡수선량과 영상의 품질을 분석하여 유용성을 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Alderson Rando Phantom, USA)의 전산화단층촬영 영상에 측정에 필요한 자궁경부와 난소의 윤곽묘사(contouring)를 하였고, 해당 장기 단면에 광자극발광선량계(Optically Stimulated Luminescence Dosimeter, OSLD, InLight system, Landauer, USA)를 각각 3개씩 부착하였다. TruebeamTM의 Pelvis mode(이하 TP)와 HalcyonTM의 Pelvis mode(이하 HP) 그리고 HalcyonTM의 Pelvis Fast mode(이하 HPF)에서 자궁경부와 난소에 들어가는 흡수선량을 측정하기 위해 촬영 범위를 17.5 cm와 12.5 cm로 촬영 범위를 축소한 영상을 촬영하였다. 총 10회의 누적선량을 합산하였고, 자궁경부암 치료 횟수인 23회의 값으로 치환하여 비교하였다. 또한 영상 장비 간의 CBCT 영상 품질을 비교하기 위해 Catphan 504 팬텀(The Phantom Laboratory, USA)을 이용하여 균일도(Uniformity), 저 대조도 가시(Low contrast visibility, LCV), 공간분해능(Spatial resolution), 기하학적 왜곡(Geometric Distortion)을 비교 분석하였다. 각각 3회 반복 측정하여 Doselab (Versions: 6.8, Mobius Medical Systems) 프로그램으로 분석 후 평균값을 구하였다. 결 과: CBCT에 의한 흡수선량을 OSLD로 측정한 결과 동일한 조건일 시 TP와 HP는 유의미한 결과를 얻지 못하였다. 가장 큰 감소 값을 보인 모드는 TP 대비 HPF였다. HPF는 17.5 cm의 촬영 범위에서 흡수선량이 TP보다 자궁경부가 약 39.82%, 난소에서 약 19.8% 감소 하였고, 12.5 cm 으로 촬영 범위를 축소할 경우 자궁경부는 34.2%, 난소 50.5%로 감소 시킬 수 있었다. 또한 위 실험에서 사용된 영상의 품질을 평가한 결과 Geometric Distortion 1mm 이내(SBRT 기준), Uniformity HU, LCV 2.0% 이내 Spatial Resolution 3 lp/mm 이상으로 장비사의 기준치를 준수하였다. 결 론: 본 실혐 결과에 따라 난소전위술을 시행한 가임기 여성의 방사선치료 시 CBCT로 인한 피폭선량을 낮추기 위해서는 TruebeamTM 보다 다양한 조건을 선택 할 수 있는 HalcyonTM이 유용할 것으로 평가 되며, 특히 낮은 mAs로도 영상의 품질을 유지하는 HalcyonTM의 Fast kV CBCT를 권장한다. 다만 다른 치료 장비에서도 난소전위를 시행한 환자는 촬영 범위를 조정하는 것으로 저선량에 대한 추가적인 피폭 감소시킬 수 있을 것으로 사료된다.

심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발 (Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT)

  • 야마모토토모아키;김정민;이기성;타카야마테루히코;키타하라타다시
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.389-399
    • /
    • 2008
  • 단일광자방출컴퓨터단층촬영(SPECT) 시 정확도의 개선을 위하여 산란과 감약의 보정, 분해능의 개선이 매우 중요하다. 특히 호흡이나 맥동에 대한 심장의 움직임은 보정 에러의 원인이 된다. 심장 팬텀이 보정방법에 대한 검증을 위해 사용되고 있으나, 현재 사용 중인 팬텀들은 실제 인체 데이터와 다른 점이 많이 나타나고 있다. 즉 팬텀을 사용한 결과는 임상데이터와 같게 취급할 수가 없다. 저자들은 흉곽의 인체 구조와 같은 신뢰성 있는 새로운 팬텀을 개발하였다. 새로운 팬텀은 폐와 심장의 전면, 측면 및 상부가 접하는 작은 종격구조를 가지고 있다. 용기는 아크릴로 만들었으며 종격은 물 등가물질을 사용하여 제조하였다. 폐는 에폭시레진의 고형 폴리우레탄 폼을 사용하였다. 5가지 크기의 심장은 게이트 심근관류 SPECT의 정량적 분석을 위하여 개발되었다. 심장팬텀들의 종격은 같은 포지션에 위치할 수 있도록 고안되었다. 완성된 팬텀은 간과 담낭에 부착되고 각각 높이 조절이 가능하다. 5개의 심실의 용적은 각각 150.0, 137.3, 83.1, 42.7과 38.6ml이다. 새로운 팬톰을 사용하여 SPECT 검사를 시행하고 보정법을 적용한 후에 영상의 차이를 검토하였다. 심장의 3차원 단층상이 효율적으로 재구성 되었으며 여러 가지 보정방법의 차이를 나타내기 위하여 주관적 평가도 시행하였다. 저자들은 SPECT영상과 QGS(Quantitative Gated SPECT) 결과로서 보정방법의 차이를 나타낼 수 있는 새로운 팬텀을 개발하여 보고하는 바이다.

  • PDF