• Title/Summary/Keyword: compression members

Search Result 321, Processing Time 0.026 seconds

Behaviour and stability of prestressed steel plate girder for torsional buckling

  • Gupta, L.M.;Ronghe, G.N.;Naghate, M.K.
    • Steel and Composite Structures
    • /
    • v.3 no.1
    • /
    • pp.65-73
    • /
    • 2003
  • A higher level of engineering standard in the field of construction, is the use of prestressing in building structures. The concept of prestressing steel structures has only recently been widely considered, despite a long and successful history of prestressing concrete members. Several analytical studies of prestressed steel girders were reported in literatures, but much of the work was not studied with reference to the optimal design and behaviour of the prestressed steel plate girder. A plate girder prestressed eccentrically, will behave as a beam-column, which is subjected to axial compression and bending moment which will cause the beam to buckle out. The study of buckling of the prestressed steel plate girder is necessary for stability criteria. This paper deals with the stability of prestressed steel plate girder using concept of "Vlasov's Circle of Stability" under eccentric prestressing force.

Long-term flexural cracking of reinforced concrete members

  • Al-Zaid, Rajeh Z.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.1
    • /
    • pp.15-27
    • /
    • 2004
  • A rational and simple analytical model to predict the time varying cracking moment of reinforced concrete sections under sustained loading is developed. The modeling procedure is based on equilibrium and compatibility requirements and takes into account the interdependent effects of creep and shrinkage as well as the presence of axial loading. A parametric study is conducted in which particular consideration is given to the effects of reinforcement ratio, level of loading, and creep and shrinkage characteristics of concrete. It is concluded that the reduction in cracking moment is mainly attributed to shrinkage. The effect of shrinkage is more pronounced at low levels of sustained loading and at high reinforcement ratios. This effect is lessened by the compression steel and creep particularly when the applied moment is near the cracking moment.

An Experimental Study of Precast Concrete Alters Cement Types of High-Strength Concrete (시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 압축강도특성을 중심으로 -)

  • Park, Heung-Lee;Ki, Jun-Do;Kim, Sung-Jin;Lee, Hoi-Keun;Park, Byung-Keun;Jung, Jang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.65-68
    • /
    • 2009
  • Recently, as architectural concrete structures become high-rise and megastructured, concrete become high-strengthened and, by ensuring products of more stability, and rationalization of construction are required.large cross-sectional precast concrete members such as columns show large temperature increase in manufacturing process not only by external heating but also by concrete itself's hydration heating. Therefore, it is expected that specimen for management to predict strength and compression strength of precast concrete member shows different strength characteristics. Concerning this, in order to suggest strength characteristics of high strength mass concrete suitable for precast concrete application, this study comprises the inclusive investigations on the relations between core strength and the strength characteristics per member cross-section dimensional value and per water-bonding material ratio value.

  • PDF

Flexural Pinching and Energy Dissipation Capacity (휨핀칭과 에너지 소산능력)

  • 박흥근;엄태성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.275-285
    • /
    • 2003
  • Pinching is an important property of reinforced concrete member which characterizes its cyclic behavior. In the present study, numerical studies were performed to investigate the characteristics and mechanisms of pinching behavior and the energy dissipation capacity of flexure-dominated reinforced concrete members. By analyzing existing experimental studies and numerical results, it was found that energy dissipation capacity of a member is directly related to energy dissipated by re-bars rather than concrete that is a brittle material, and that it is not related to magnitude of axial compressive force applied to the member. Therefore, for a member with specific arrangement and amount of re-bars, the energy dissipation capacity remains uniform regardless of the flexural strength that is changed by the magnitude of axial force applied. Due to the uniformness of energy dissipation capacity pinching appears in axial compression member. The flexural pinching that is not related to shear force becomes conspicuous as the flexural strength increases relatively to the uniform energy dissipation capacity. Based on the findings, a practical method for estimating energy dissipation capacity and damping modification factor was developed and verified with existing experiments.

  • PDF

Evaluation of Mechanical Behavior of Aluminum-Perforated Sheet Reinforced Mortars by Industrial By-Products (산업부산물 알루미늄 타공시트 보강 모르타르의 역학적 거동 평가 )

  • Choi, Youn Sung;Kim, Gyu-Yong;Lee, Yae Chan;Eu, Ha Min;Han, Seung Hyeon;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.49-50
    • /
    • 2023
  • The purpose of this study was to review ways to increase mechanical performance and apply to actual structures by reinforcing AL perforated sheets, which are industrial by-products generated after capacitor production, with mortar to reinforce the stress of structural members. The AL perforated sheet was reinforced so that it behaves integrally at the position receiving compression, tension, and bending stress. It was confirmed that the stress received by the AL perforated sheet increased according to the number of reinforcements, and as a result, the mechanical properties were improved.

  • PDF

Evaluation of Tensile Material Properties and Confined Performance of GFRP Composite Due to Temperature Elevation (콘크리트 횡구속용 GFRP 보강재의 온도변화에 따른 인장 재료특성 및 구속성능 평가)

  • Jung, Woo-Young;Kim, Jin-Sup;Kwon, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3562-3569
    • /
    • 2013
  • The performance of concrete structure decreases with change in time and the external environment. In order to reinforce the structure, the research about new material development and application of newly developed materials are widely conducted. In the case of composite FRP, it received good attention in the academia due to its high intensity-weight ratio, excellent corrosion resistency as well as good workability. When applying at the construction field, however, the utilization of FRP did not increase as much due to lack of reliability and design standard. Current study investigated the material characteristics during the temperature change at high temperature and the structural behavior from restraint effect for GFRP reinforcing materials. Two experimental variables were set in this study: GFRP reinforcements due to tensile properties of temperature and restraint compression effects. Three concrete specimen were selected for each set temperatures. For this reason, as a variable to experiment with the effects confined compression concrete members value and tensile properties with temperature reinforcement GFRP, experiment produced three pieces each for each set temperature, the concrete specimen, which is confined in the GFRP was selected each I did. For the temperature change during the experiment, the concrete specimen were mounted in order to expose to experimental high temperature for certain period of time. For compression performance evaluation, reinforcement effect from horizontal constraint of the fiber were measured using an Universal Material Testing Machine (UTM). Finally, this study revealed that the binding characteristics of GFRP materials from temperature change decreased. Also, this study showed that the maximum compression intensity decreased as the temperature increased up to $150^{\circ}C$ in the constraints ability of the GFRP reinforcements during the horizontal constraint of concrete.

Flexural Design of Double Composite Box Girder over Interior Pier by LRFD Method (LRFD법에 의한 이중합성 박스거더 최대부모멘트 단면 휨 설계)

  • Cho, Eun Young;Shin, Dong Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.737-749
    • /
    • 2007
  • Flexural design of double composite box girder over the interior pier for three-span continuous bridge was performed by the LRFD method. The maximum span length of the continuous bridge ranged from 80m to 120m and the relative ratio of the span length was assumed to be 1:1.25:1. The girder section was designed for the strength limit state and service limit state with additional design check for constructibility. Before the bottom concrete and compression flange showed a complete composite action, the buckling of lower compression flange was checked. The flexural stiffness and flexural resistance characteristics for the section and for the constituent members such as tension flange, compression flange, and web were analyzed for different thicknesses of the bottom concrete on top of the compression flange. The effect of the distribution ratio of steel between the top and bottom flanges was investigated by analyzing ductility behavior and stress distribution through the girder's depth for several different relative area ratios of steel between the top and bottom flanges. It was found that a total amount of 15% of steel can be saved by applying the double composite system compared with that of the conventional composite system.

Pinching and Energy Dissipation Capacity of Flexure-Dominated RC Members (휨지배 철근콘크리트 부재의 핀칭과 에너지 소산능력)

  • Park, Hong-Gun;Eom, Tae-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.594-605
    • /
    • 2003
  • Pinching is an important property of reinforced concrete member which characterizes its cyclic behavior. In the present study, numerical studies were performed to investigate the characteristics of pinching behavior and the energy dissipation capacity of flexure-dominated reinforced concrete members. By investigating existing experiments and numerical results, it was found that flexural pinching which has no relation with shear action appears in RC members subject to axial compression force. However, members with specific arrangement and amount of re-bars, have the same energy dissipation capacity regardless of the magnitude of the axial force applied even though the shape of the cyclic curve varies due to the effect of the axial force. This indicates that concrete as a brittle material does not significantly contribute to the energy dissipation capacity though its effect on the behavior increases as the axial force increases, and that energy dissipation occurs primarily by re-bars. Therefore, the energy dissipation capacity of flexure-dominated member can be calculated by the analysis on the cross-section subject to pure bending, regardless of the actual compressive force applied. Based on the findings, a practical method and the related design equations for estimating energy dissipation capacity and damping modification factor was developed, and their validity was verified by the comparisons with existing experiments. The proposed method can be conveniently used in design practice because it accurately estimates energy dissipation capacity with general design parameters.

Risk Factors Associated with Subdural Hygroma after Decompressive Craniectomy in Patients with Traumatic Brain Injury : A Comparative Study

  • Jeon, Sei-Woong;Choi, Jong-Hun;Jang, Tae-Won;Moon, Seung-Myung;Hwang, Hyung-Sik;Jeong, Je-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.355-358
    • /
    • 2011
  • Objective : Subdural hygroma (SDG) is a complication occurring after head trauma that may occur secondary to decompressive craniectomy (DC). However, the mechanism underlying SDG formation is not fully understood. Also, the relationship between the operative technique of DC or the decompressive effect and the occurrence and pathophysiology of SDG has not been clarified. Purpose of this study was to investigate the risk factors of SDG after DC in our series. Methods : From January 2004 to December 2008, DC was performed in 85 patients who suffered from traumatic brain injury. We retrospectively reviewed the clinical and radiological features. For comparative analysis, we divided the patients into 2 groups : one group with SDG after craniectomy (19 patients; 28.4% of the total sample), the other group without SDG (48 patients; 71.6%). The risk factors for developing SDG were then analyzed. Results : The mean Glasgow Outcome Scale (GOS) scores at discharge of the groups with and without SDG were 2.8 and 3.1, respectively (p<0.0001). Analysis of radiological factors showed that a midline shift in excess of 5 mm on CT scans was present in 19 patients (100%) in the group with SDG and in 32 patients (66.7%) in the group without SDG (p<0.05). An accompanying subarachnoid hemorrhage (SAH) was seen in 17 patients (89.5%) in the group with SDG and in 29 patients (60.4%) in the group without SDG (p<0.05). Delayed hydrocephalus accompanied these findings in 10 patients (52.6%) in the group with SDG, versus 5 patients (10.4%) in the group without SDG (p<0.05). On CT, compression of basal cisterns was observed in 14 members (73.7%) in the group with SDG and in 18 members of the group without SDG (37.5%) (p<0.007). Furthermore, tearing of the arachnoid membrane, as observed on CT, was more common in all patients in the group with SDG (100%) than in the group without SDG (31 patients; 64.6%) (p<0.05). Conclusion : GOS showed statistically significant difference in the clinical risk factors for SDG between the group with SDG and the group without SDG. Analysis of radiological factors indicated that a midline shifting exceeding 5 mm, SAH, delayed hydrocephalus, compression of basal cisterns, and tearing of the arachnoid membrane were significantly more common in patients with SDG.

Flexural-Shear Behavior of Beam Members according to the Spacing of Stirrups and Tension Steel Ratio (스터럽간격과 인장철근비에 따른 고강도 콘크리트 보의 파괴거동)

  • Park, Hoon-Gyu;An, Young-Ki;Jang, Il-Young;Choi, Goh-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.513-521
    • /
    • 2003
  • Existing tests results have shown that confining the concrete compression region with closed stirrups improves the ductility and load-carrying capacity of beams. However, only few researchers have attempted to utilize the beneficial effects of the presence of these stirrups in design. This paper presents the result of experimental studies on the load-deflection behavior and the strengthening effect of laterally confined structural high-strength concrete beam members in which confinement stirrups have been introduced into the compression regions. Fifteen tests were conducted on full-scale beam specimens having concrete compressive strength of 41 MPa and 61 MPa. Different spacing of stirrups(0.25∼1.0d) and amount of tension steel($0.55{\sim}0.7{\rho}_b$) as major variables were investigated. And also, this study present an appropriate shear equation for decision of ultimate failure modes of high-strength concrete beams according to stirrup spacing. The equation is based on interaction between shear strength and displacement ductility. Prediction of failure mode from presented method and comparison with test results are also presenteded