• 제목/요약/키워드: composite steel-concrete bridges

검색결과 199건 처리시간 0.023초

After-fracture behaviour of steel-concrete composite twin I-girder bridges: An experimental study

  • Lin, Weiwei
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.139-149
    • /
    • 2022
  • To simplify the design and reduce the construction cost of traditional multi-girder structural systems, twin I-girder structures are widely used in many countries in recent years. Due to the concern on post-fracture redundancy, however, twin girder bridges are currently classified as fracture critical structures in AASHTO specifications for highway bridges. To investigate the after-fracture behavior of such structures, a composite steel and concrete twin girder specimen was built and an artificial fracture through the web and the bottom flange was created on one main girder. The static loading test was performed to investigate its mechanical performance after a severe fracture occurred on the main girder. Applied load and vertical displacement curves, and the applied load versus strain relationships at key sections were measured. To investigate the load distribution and transfer capacities between two steel girders, the normal strain development on crossbeams was also measured during the loading test. In addition, both shear and normal strains of studs were also measured in the loading test to explore the behavior of shear connectors in such bridges. The functions and structural performance of structural members and possible load transfer paths after main girder fractures in such bridges were also discussed. The test results indicate in this study that a typical twin I-girder can resist a general fracture on one of its two main girders. The presented results can provide references for post-fracture performance and optimization for the design of twin I-girder bridges and similar structures.

Behavior of steel-concrete composite cable anchorage system

  • Gou, Hongye;Wang, Wei;Shi, Xiaoyu;Pu, Qianhui;Kang, Rui
    • Steel and Composite Structures
    • /
    • 제26권1호
    • /
    • pp.115-123
    • /
    • 2018
  • Steel-concrete composite structure is widely applied to bridge engineering due to their outstanding mechanical properties and economic benefit. This paper studied a new type of steel-concrete composite anchorage system for a self-anchored suspension bridge and focused on the mechanical behavior and force transferring mechanism. A model with a scale of 1/2.5 was prepared and tested in ten loading cases in the laboratory, and their detailed stress distributions were measured. Meanwhile, a three-dimensional finite element model was established to understand the stress distributions and validated against the experimental measurement data. From the results of this study, a complicated stress distribution of the steel anchorage box with low stress level was observed. In addition, no damage and cracking was observed at the concrete surrounding this steel box. It can be concluded that the composite effect between the concrete surrounding the steel anchorage box and this steel box can be successfully developed. Consequently, the steel-concrete composite anchorage system illustrated an excellent mechanical response and high reliability.

Finite element model for the long-term behaviour of composite steel-concrete push tests

  • Mirza, O.;Uy, B.
    • Steel and Composite Structures
    • /
    • 제10권1호
    • /
    • pp.45-67
    • /
    • 2010
  • Composite steel-concrete structures are employed extensively in modern high rise buildings and bridges. This concept has achieved wide spread acceptance because it guarantees economic benefits attributable to reduced construction time and large improvements in stiffness. Even though the combination of steel and concrete enhances the strength and stiffness of composite beams, the time-dependent behaviour of concrete may weaken the strength of the shear connection. When the concrete loses its strength, it will transfer its stresses to the structural steel through the shear studs. This behaviour will reduce the strength of the composite member. This paper presents the development of an accurate finite element model using ABAQUS to study the behaviour of shear connectors in push tests incorporating the time-dependent behaviour of concrete. The structure is modelled using three-dimensional solid elements for the structural steel beam, shear connectors, concrete slab and profiled steel sheeting. Adequate care is taken in the modelling of the concrete behaviour when creep is taken into account owing to the change in the elastic modulus with respect to time. The finite element analyses indicated that the slip ductility, the strength and the stiffness of the composite member were all reduced with respect to time. The results of this paper will prove useful in the modelling of the overall composite beam behaviour. Further experiments to validate the models presented herein will be conducted and reported at a later stage.

강재매입형 합성기둥의 합성작용에 관한 실험 (Experiments on the Composite Action of Steel Encased Composite Column)

  • 정인근;민진;심창수;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.485-488
    • /
    • 2004
  • Steel encased composite columns have been used for buildings and piers of bridges. Since column section for pier is relatively larger than that of building columns, economical steel ratio need to be investigated for the required performance. Composite action between concrete and embedded steel sections can be obtained by bonding and friction. However, the behavior. of the column depends on the load introduction mechanism. Compression can be applied to concrete section, steel section and composite section. In this paper, experiments on shear strength of the steel encased composite column were performed to study the effect of confinement by transverse reinforcements, mechanical interlock by holes, and shear connectors. Shear strength obtained from the tests showed considerably higher than the design value. Confinement, mechanical interlock and stud connectors increased the shear strength and these values can be used effectively to obtain composite action of SRC columns.

  • PDF

Influence of creep on dynamic behavior of concrete filled steel tube arch bridges

  • Ma, Yishuo;Wang, Yuanfeng;Su, Li;Mei, Shengqi
    • Steel and Composite Structures
    • /
    • 제21권1호
    • /
    • pp.109-122
    • /
    • 2016
  • Concrete creep, while significantly changing the static behaviors of concrete filled steel tube (CFST) structures, do alter the structures' dynamic behaviors as well, which is studied quite limitedly. The attempt to investigate the influence of concrete creep on the dynamic property and response of CFST arch bridges was made in this paper. The mechanism through which creep exerts its influence was analyzed first; then a predicative formula was proposed for the concrete elastic modulus after creep based on available test data; finally a numerical analysis for the effect of creep on the dynamic behaviors of a long-span half-through CFST arch bridge was conducted. It is demonstrated that the presence of concrete creep increases the elastic modulus of concrete, and further magnifies the seismic responses of the displacement and internal force in some sections of the bridge. This influence is related closely to the excitation and the structure, and should be analyzed case-by-case.

교량용 강ㆍ콘크리트 합성 바닥판 단위모델의 부재별 거동 특성 (Behavior of Members in the Unit Model of Steel-Concrete Hybrid Deck for Bridges)

  • 정광회;정연주;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.493-498
    • /
    • 2003
  • The 3D nonlinear analysis for steel-concrete hybrid deck is carried out by utilizing 2D plane interface element. The effect of the slip occurred between steel and concrete can be modeled by this element. This analysis focuses on not only global behavior of steel-concrete hybrid deck but also local behaviors of members of it such as lower steel plate, I-beam, and concrete which are varied by slip modulus. In this analysis, it was founded that the limit slip modulus could classify the states of steel-concrete hybrid deck into three parts such as full-composite, partial-composite, and non-composite, considering the behavior of lower steel plate, I-beam, and concrete at the mid span and the support as well as the yield load and ultimate load of it.

  • PDF

대구경 합성강관말뚝 설계 기법에 관한 연구 (Design Method of Large-Scale Concrete-Steel Composite Drilled Shafts)

  • 최구용;양종호;최석환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.299-302
    • /
    • 2005
  • Generally, steel-concrete composite structures are considered very useful and powerful to resist external axial and flexural load due to its elevated capacity originated from composite action. This usefulness of composite structures can be applied to the drilled shafts of marine bridges that require large-scale such as entire pile-column system. As the basic study of this application, several design codes are analyzed and compared in this research.

  • PDF

강합성형 교량의 합리적인 타설방법과 순서에 관한 연구 (The Reasonable Concrete-Placing Methods and Sequences of Composite Steel Bridge)

  • 조병완;서석구
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권2호
    • /
    • pp.205-212
    • /
    • 1999
  • Recently, unexpected cracks in the concrete deck slab of composite steel bridges have been widely reported at an early age of concrete placing due to the concrete placing sequence and methods. Accordingly, the analytical research was carried out to verify the negative moment at an internal supports due to the several concrete pouring sequence and to determine the reasonable concrete placing method on the deck slab of composite steel bridge. The results show that the conventional concrete-placing method, which pours concrete first on the positive moment regions and then negative regions, leads to the minimum moment at an internal supports. However, the conventional method produces two impractical construction joints on every spans and makes field engineer to pour concrete continuously. In conclusion, this concrete-placing method was verified to be reasonable only when the construction joint was placed at the $\frac{5}{8}l{\sim}\frac{6}{8}l$ location of the middle span.

  • PDF

주형과 상판과의 상호작용이 단순 사교의 동적거동에 미치는 영향 (Effects of Interactions between the Concrete Deck and Steel Girders on the Dynamic Behavior of Simply Supported Skew Bridges)

  • 문성권
    • 한국전산구조공학회논문집
    • /
    • 제20권5호
    • /
    • pp.593-604
    • /
    • 2007
  • 합성형 사교는 비합성형 사교에 비해 역학적 측면에서 큰 장점을 지니고 있는 것이 사실이지만 사각이 심한 사교들의 경우 합성형 사교에 매우 큰 상판응력이 유발될 가능성이 있어 종종 이들 사교들에 대한 비합성형 설계가 검토되어지곤 한다. 본 연구에서는 동적해석이 가능한 비합성형 사교의 해석모델을 제안하고 이 해석모델들을 이용하여 사교들에 대한 비합성형의 적용 타당성을 검토하였다. 또한 주형과 상판과의 세 가지 상호작용(합성작용, 부분합성작용, 비합성작용)이 단순 판형사교들의 동적특성과 동적거동에 미치는 영향을 조사하였다. 주형간격, 사각, 상판 종횡비를 매개변수로 총 27개의 판형 사교들에 대한 일련의 연구를 수행하였다. 상판과 주형 경계면에서의 미끄러짐은 고유진동주기가 길어지는 현상을 유발하여 사교의 교축직각방향에 작용하는 전체밑면전단력의 크기를 감소시킬 수도 있지만 모드형장과 강성분포에 큰 영향을 미쳐 바람직하지 않은 사교 거동을 유발할 수도 있다. 부분합성작용의 최소 규정에 따라 설치된 전단연결재는 주형응력과 상판응력을 감소시키는 효과가 있다. 즉, 몇몇 사교의 경우를 제외하고는 전반적으로 부분합성형으로부터 구한 주형응력과 상판응력의 크기는 합성형 사교로부터 구한 관련 응력들의 크기와 유사하거나 약간 크게 나타난다.

합성거더교의 등가 건조수축 변형률 (Equivalent Shrinkage Strain For Steel-Concrete Composite Girder Bridges)

  • 배두병;정대준
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.135-144
    • /
    • 2004
  • 현대 교량이 연속화, 장대화되어 가는 추세에 따라 강-콘크리트 합성거더교의 내구성 및 안전성 확보를 위해 콘크리트의 건조수축과 크리프 등 장기거동에 의한 영향이 정확히 평가 산정되어야 한다. 그러나, 현 도로교 설계기준에 주어진 최종 건조수축 변형률은 $180^{1\;2}$인데 이는 실험적 연구 등을 통해서 밝혀진 값보다 현저히 작은 값으로 여러 시공사례에서 문제점이 발견되고 있는 등 건조수축에 의한 영향이 과소평가 되고 있어 이에 대한 수정이 필요한 시점에 있다. 이에 본 논문에서는 바닥판으로 콘크리트 슬래브를 적용한 플레이트 거더교 박스 거더교, 플리플렉스빔교를 대상으로 콘크리트 구조설계기준에 제시된 건조수축 및 크리프에 대한 규정을 적용하여 시간단계별 비선형 해석을 수행하였고, 얻어진 결과를 도로교 설계기준에 따라 산정된 값들과 비교 분석하여, 최종적으로 비선형 해석의 결과와 동일한 응력을 발생시키는 선형등가 건조수축 변형률을 산정하였다. 그 결과 도로교 설계기준에서 제시한 $180^{1\;2}$ 보다 대략 2배의 값을 적용하는 것이 실제의 건조수축의 영향을 반영하는 것으로 나타났다.