• 제목/요약/키워드: composite connection

검색결과 667건 처리시간 0.022초

Experimental Study on Shear Connector for Precast Concrete Decks

  • Chung, Chul-Hun;Shim, Chang-Su;Jeong, Un-Yong
    • KCI Concrete Journal
    • /
    • 제13권1호
    • /
    • pp.61-67
    • /
    • 2001
  • For the design of shear connection for the composite precast concrete slabs. it is necessary to investigate its strength, stiffness, slip capacity and fatigue endurance. For theme purposes, push-out tests were performed with variations of the stud shank diameter and the compressive strength of the mortar. From the experimental studies, it could be observed that the deformation of the shear studs in a full-depth precast concrete slabs were greater than those in a cast-in-place slabs. The static strength of the shear connections obtained agree approximately with those evaluated from the tensile strength of the stud shear connectors owing to the effect of the bedding layer between the slabs and the beams. An empirical equation for the initial shear stiffness of a shear connection was also proposed. On the basis of the push-out tests, a full-scale composite beams with 8.0m span was designed and fatigue tests were carried out to study the behaviour of the stud shear connection and its effects on the flexural behaviour of the beam. The bonding arid friction between the concrete slab and the steel beam considerably increased the fatigue endurance of the shear connection.

  • PDF

중공단면 복합소재 교량 바닥판의 시험을 통한 구조적 특성 분석 (Experimental Study on the Composite Bridge Deck of Hollow Section)

  • 이성우;김병석;홍기증
    • 한국전산구조공학회논문집
    • /
    • 제19권4호
    • /
    • pp.325-335
    • /
    • 2006
  • 본 논문에서는 설계와 해석을 거쳐 인발성형으로 제작된 중공단면 복합소재 교량 바닥판에 대해 휨 성능시험, 바닥판-거더 연결부시험, 바닥판-방호벽 연결부시험 등을 통해 구조적 특성을 분석하였다. 휨시험체에 지간 중앙에 변위계와 상 하부판의 주요부에 변형률계를 부착하여 파괴하중 재하시까지 거동을 계측하고 그 결과를 분석하였다. 휨시험체에 대한 유한요소해석도 실시하여 시험결과와 비교분석하였으며, 휨에 대한 극한 내하력을 추정하였다. 또한, 시범시공된 복합소재 바닥판 플레이트 거더 교량에 대한 현장 재하시험결과와 현장적용사례를 기술하였다.

합성 PC부재의 Steel-joint Connection Method 개발 기초연구 (A basic study of steel-joint connection method of composite precast concrete members)

  • 김근호;이동훈;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2013
  • Green Frame is a column-beam system formed by composite precast concrete column and beam connected with steel buried in both members. During the installation of Green columns, the columns of Green Frame, covering 3 floors per each piece and beams, the eccentricity can be observed due to the construction error and the weight of beam itself. Such eccentricity may have a little influence on a single frame, yet, it can develop critical issues to the installation of subsequent beams or beams on the upper floors in the context of a building as a whole that has multiple frames. These issues lead to delay in frame installation, decrease of productivity and increase of cost, etc. Therefore, this study presents a steel-joint connection method in order to solve the issues. The steel-joint connection method exists on slope plane and reinforcing plate in steel frame buried in composite PC members. Through this method, the issues can be resolved without requiring additional equipment or manpower.

  • PDF

부모멘트를 받는 합성보의 전단합성 거동에 대한 유한요소해석 (FE Analysis of the Composite Action in the Composite Beam subjected to the Hogging Moment)

  • 신현섭
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.4048-4057
    • /
    • 2013
  • 부모멘트를 받는 합성보 슬래브에서 인장균열 발생과 균열의 진행에 따른 슬래브의 강성저하가 전단연결부의 합성거동에 미치는 영향을 실험적으로 분석하기는 매우 어렵다. 본 논문에서는 부모멘트를 받는 합성보에서 콘크리트 슬래브 및 강재 보, 스터드를 포함한 전단연결부 등의 형상과 물성을 최대한 실제와 유사하게 모델링하는 기법을 이용함으로써, 부재 간 합성작용을 해석할 수 있는 3차원 유한요소모델을 개발하였다. 개발된 3차원 유한요소모델을 이용하여 부모멘트 구간에 설치되는 합성보의 전체 휨거동 및 기존의 1차원 또는 2차원 모델로는 해석이 어려운 전단합성작용을 분석할 수 있었다. 해석결과에 따르면 부모멘트를 받는 합성보에서의 전단연결부 거동은 철근콘크리트 슬래브의 철근비 및 인장 균열거동에 지배를 받게 됨을 알 수 있었다. 전단연결부의 하중-슬립 관계를 검토해 본 결과, 전단연결부의 슬립강성은 슬래브의 초기균열 및 철근의 항복이 발생한 시점을 기준으로 변화됨을 알 수 있었다. 또한, 구간별로 합성율이 100% 미만으로 설계되는 부분합성 설계가 합성설계의 효율성 측면에서 더 유리할 수 있다는 기존의 실험적 연구결과를 간접적으로 확인할 수 있었다.

무량판 슬래브와 H형강 기둥 접합부 상세 개발 (Development for Connection Details between Flat Plate Slab and H-Steel Column)

  • 윤명호;이윤희
    • 복합신소재구조학회 논문집
    • /
    • 제5권1호
    • /
    • pp.22-27
    • /
    • 2014
  • The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.

Behaviour evaluation of shear connection by means of shear-connection strips

  • Rovnak, Marian;Duricova, Antonia
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.247-263
    • /
    • 2004
  • Comparison of behaviour of shear connections by means of shear-connection strips (perfobond and comb-shaped strips) and headed studs under static and repeated loading, possible failure modes of concrete dowels and ways of the quantitative differentiation of some failure modes are described in the paper. The article presents a review of knowledge resulting from the analysis of shear-connection effects based on tests of perfobond and comb-shaped strips carried out in the laboratories of the Faculty of Civil Engineering of the Technical University of Kosice (TU of Kosice) in Slovakia and their comparison with results obtained by other authors.

나사형 철근을 사용한 합성 PC기둥의 접합방법 (Connection Method of Composite Precast Concrete Columns Using Thread Rebar)

  • 김태구;이성호;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.14-15
    • /
    • 2013
  • Green Frame is precast concrete column-beam structure. There are three types on column connection. The coupler type which is one of the three, need to be improved because of unstability caused by pre-installation of column before casting the slab, and quality deterioration caused by lack of workspace. Therefore, in this study, new coupler connection type with thread rebar is suggested. The result of this study shall be used for the efficiency analysis of the new coupler connection.

  • PDF

Improvement of the behaviour of composite slabs: A new type of end anchorage

  • Fonseca, Alexandre;Marques, Bruno;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1381-1402
    • /
    • 2015
  • The application of composite steel-concrete slabs with profiled steel sheeting has increased, due to the various advantages in relation to reinforced concrete slabs such as, the reduced thickness, the reduced amount of lost formwork needed, as well as the speed of execution. The loss of longitudinal shear resistance is, generally, the governing design mode for simply supported spans of common lengths. For common distributed loadings, the composite behaviour is influenced by the partial shear connection between the concrete and the steel sheeting. The present research work is intended to contribute to improving the ultimate limit state behaviour of composite slabs using end anchorage. Eurocode 4, Part 1.1 (EN 1994-1-1) provides an analytical methodology for predicting the increase of longitudinal resistance, achieved by using shear studs welded through the steel sheeting as the end anchorage mechanism. The code does not supply an analytical methodology for other kinds of end anchorage so, additional tests or studies are needed to prove the effectiveness of these types of anchorage. The influence of end anchorage mechanisms provided by transverse rebars at the ends of simply supported composite slabs is analysed in this paper. Two experimental programmes were carried out, the first to determine the resistance provided by the new end anchorage mechanism and the second to analyse its influence on the behaviour of simply supported composite slabs.

Behaviour and design of composite beams subjected to flexure and axial load

  • Kirkland, Brendan;Uy, Brian
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.615-633
    • /
    • 2015
  • Composite steel-concrete beams are used frequently in situations where axial forces are introduced. Some examples include the use in cable-stayed bridges or inclined members in stadia and bridge approach spans. In these situations, the beam may be subjected to any combination of flexure and axial load. However, modern steel and composite construction codes currently do not address the effects of these combined actions. This study presents an analysis of composite beams subjected to combined loadings. An analytical model is developed based on a cross-sectional analysis method using a strategy of successive iterations. Results derived from the model show an excellent agreement with existing experimental results. A parametric study is conducted to investigate the effect of axial load on the flexural strength of composite beams. The parametric study is then extended to a number of section sizes and employs various degrees of shear connection. Design models are proposed for estimating the flexural strength of an axially loaded member with full and partial shear connection.

Steel-Plate 매입형 합성 연결보의 접합부 상세에 따른 내진거동 (Seismic Behavior by Beams-Wall Connections depending upon Joint Details of Embedded Steel-Plate Composite Coupling Beams)

  • 주재형;채승윤;김선규;김우재;전호민;박효선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.130-133
    • /
    • 2006
  • Owing to Higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. It has been researched a lot of methods as an alternative plan about these but designer cannot apply them for the reason ; the structure standard and theory background are not taking a triangular position. As accomplishing the test research about the beams-wall connections department of steel-plate composite coupling beams from the research in the study it examines closely the beams-wall connections conduct quality and tries to provide the fundamental data for reasonable and optimum connection department designs. It knows that connection fixation degree and composite conduct degree of member part together become the important variable showing an energy dissipation ability in Test result.

  • PDF