• Title/Summary/Keyword: complex electric field

Search Result 130, Processing Time 0.031 seconds

Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests (상용화 드론을 이용한 송전선로 점검방안 및 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan;Choi, Min-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • Various types of robots running on power transmission lines have been developed for the purpose of line patrol monitoring. They usually have complex mechanism to run and avoid obstacles on the power line, but nevertheless did not show satisfactory performance for going over the obstacles. Moreover, they were so heavy that they could not be easily installed on the lines. To compensate these problems, flying robots have been developed and recently, multi-copter drones with flight stability have been used in the electric power industry. The drones could be remotely controlled by human operators to monitor power distribution lines. In the case of transmission line patrol, however, transmission towers are huge and their spans are very long, and thus, it is very difficult for the pilot to control the patrol drones with the naked eye from a long distance away. This means that the risk of a drone crash onto electric power facilities always resides. In addition, there exists another danger of electromagnetic interference with the drones on autopilot waypoint tracking under ultra-high voltage environments. This paper presents a patrol monitoring plan of autopilot drones for power transmission lines and its field tests. First, the magnetic field effect on an autopilot patrol drone is investigated. Then, how to build the flight path to avoid the magnetic interference is proposed and our autopilot drone system is introduced. Finally, the effectiveness of the proposed patrol plan is confirmed through its field test results in the 154 kV, 345 kV and 765 kV transmission lines in Chungcheongnam-do.

A Study on The Effect of Power conversion system for De-wiring Trolley wire by Electric Railway System (전기철도 전차선 이선이 전력변환장치에 미치는 영향 연구)

  • Shin, Seung-Chul;Kim, Jae-Chul;Han, Seong-Ho;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.381-383
    • /
    • 2006
  • A de-wiring trolley wire usually makes the electrical system complex and may have an adverse effect on the electrical system inside the train. It is important to analyze the effect on trains in de-wiring trolley wire. we accomplished an equivalent model of the electric train system. We used PSCAD/EMTDC, an electromagnetic transient program. The result of this study can be used as a facility design to use a power conversion system filter and needs to prove through actual field data in the main circuit of an electric train for a precise analysis about effect of de-wiring.

  • PDF

Analysis of Iron Loss Caused by Non sinusoidal Magnetic Behavior in Motor Core (모터 코아 내부에서 비정현적 자계의 거동에 따른 철손 해석)

  • Ha, Kyung-Ho;Cha, Sang-Yoon;Kim, Jae-Kwan;Lim, Yang-Su;Hur, Yoon;Hong, Jeong-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1071-1073
    • /
    • 2005
  • This paper investigates magnetic field behavior and its iron losses in the stator core using electrical steels. The analysis model is a brushless motor with the permanent magnet. The elliptical rotating and alternating flux distributions with non-sinusoidal waveforms are obtained by Finite Element Method and then their harmonic components are extracted. Based on these results, the local iron losses in the stator core caused by the harmonic flux are calculated. Furthmore, this paper explains the relation between the complex flux waveform and iron loss produced in each part of the stator core.

  • PDF

Electrical Breakdown and Flashover Characteristics of Gaseous Helium at Cryogenic Temperature (극저온 헬륨가스의 절연파괴 및 연면방전 특성)

  • Kwag, Dong-Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.38-42
    • /
    • 2012
  • Fixtures such as bushings in terminations of high temperature superconducting(HTS) power cable systems are subjected to high voltages, which have to transition from ambient to cryogenic temperatures. As such it is imperative to ensure the integrity of the dielectrics under all operating conditions, including thermal aspects brought about by the passage of current. Gaseous helium(GHe) at high pressure is regarded as a potential coolant for superconducting cables. The dielectric aspects of cryogenic helium gas are both complex and demanding. In this experimental study we looked at the interface between a smooth epoxy surface and high pressure helium gas in a homogeneous electric field. The alternating current(AC) flashover voltages of epoxy samples are presented. The results have been analyzed by using Weibull statistics. In addition to the behavior of the epoxy in gaseous helium as a function of pressure and temperature we also present data of the characteristics of the epoxy in mineral oil and in liquid nitrogen($LN_2$). The breakdown characteristics of a uniform field gap in gaseous helium as a function of pressure and temperature under AC, direct current(DC) and lightning impulse voltages are also given. Electric field calculations have been made for one of the experimental geometries in an attempt to explain some of the anomalies in the experimental results.

Estimation of Discharge Current Waveshapes in Short Gap Discharge by Radiated Electromagnetic Fields (방사 전자파에 의한 미소 간극 방전원의 방전 전류파형 추정)

  • 김기채;이광식;이동인
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.259-267
    • /
    • 2000
  • This paper presents the method for an estimation of discharge current waveshapes in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation described is using the one antenna method(single field method) and two antennal method(complex field method) with a measured electric or magnetic fields at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveshape estimation was performed by one and two antenna methods using the measured electric fields of Wilson & Ma and compared with experiments.

  • PDF

Introduction of Calmodulin into Suspension-Cultured Cells and Protoplasts of Soybean (Glycine max L.) (대두(Glycine max L.) 현탁배양 세포와 원형질체 내로의 외부 Calmodulin의 도입)

  • Hyun Sook CHAE;Kyu Chung HUR;In Sun YOON;Bin G. KANG
    • Korean Journal of Plant Tissue Culture
    • /
    • v.21 no.6
    • /
    • pp.363-367
    • /
    • 1994
  • In an effort to investigate the role of calmodulin (CaM) as a modulating molecule in the signal transduction system in plant cells, we established methods for introduction of purified CaM into cultured soybean cells. CaM was purified from bovine testis, and was labelled with fluorescein isothiocyanate (FITC). Suspension -cultured cells were healed with saponin (0.1 mg/mL) to permeabilize the plasma membrane and coincubated with FITC-CaM complex. Saponin pretreatment was found to increase the fluorescence in the suspension cultured cells, indicating that the FITC-CaM complex could be incorporated into the cytoplasm. Optimal conditions for introducing FITC-CaM complex into protoplasts by electroporation were established with various electric pulses. With increasing field strength, the fluorescence in the protoplase was increased, while the viability of the protoplase decreased. FITC-CaM complex was successfully introduced into the protoplasts by electroporation and the amount of FITC-CaM complex in the protoplase was estimated.

  • PDF

Development of Experimental Device for Analysis of Hydraulic Oil Characteristics with Dielectric Constant Sensors (유전상수 센서를 이용한 유압 작동유의 분석을 위한 실험장비 개발)

  • Hong, Sung-Ho
    • Tribology and Lubricants
    • /
    • v.37 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • An experimental device was developed for analysis of hydraulic oil characteristics with dielectric constant sensors. Online analysis is the most effective method of the three methods used for analyzing lubricant oils. This is because it can monitor the machine condition effectively using oil sensors in real time without requiring excellent analysis skill and eliminates human errors. Determining the oil quality usually requires complex laboratory equipment for measuring factors such as density, viscosity, base number, acid number, water content, additive, and wear debris. However, the electric constant is another indicator of oil quality that can be measured on-site. The electric constant is the ratio of the capacitance of a capacitor using that material as a dielectric, compared with a similar capacitor that has a vacuum as its dielectric. The electric constant affects the factors such as the base oil, additive, temperature, electric field frequency, water content, and contaminants. In this study, the tendency of the electric constant is investigated with a variation of temperature, water content, and dust weight. The experimental device can control working temperature and mix the contaminants with oil. A machine condition monitoring program developed to analyze hydraulic oil is described. This program provides graph and digital values with variation of time. Moreover, it includes an alarm system for when the oil condition is bad.

A Study on the Analysis of Discontinuity of Microstrip Line Using FDTD/GPOF Method (FDTD/GPOF법을 이용한 Microstrip Line 불연속부의 해석에 관한 연구)

  • 김동일;이태형
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 1998
  • In this paper, discontinuity parts in microstrip line with $\lambda$/4 open stub and one in crank type have been anlayzed by using FDTD(Finite-Difference Time-Domain) analysis method. The noise components, in this case, are occred at the discontinuites of the given microstrip lines, the complex poles were extracted by the analysis using GPOF (Generalized Pencil-of Function) method from electric field of time domain. It has, then, been found that the noise level and the noise frequency components included in signal could be derived.

  • PDF

Vibration Characteristics and Control of Smart Cantilever Beams Containing an Electro-Rheological Fluid An Experimental Investigation (전기 유동유체를 함유하는 지능외팔보의 진동특성 및 제어 실험적 고찰)

  • Choi, Seung-Bok;Park, Yong-Kun;Suh, Moon-Suk
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1649-1657
    • /
    • 1993
  • This paper reports on a proof-of-concept experimental investigation focused on evaluating the vibration characteristics and control of smart hollow cantilever beams filled with an electro-rheological(ER) fluid. The beams are considered to be of uniform viscoelastic materials and modelled as a viscously-damped harmonic oscillator. Electric field-dependent natural frequencies, loss factors and complex moduli are evaluated and compared among three different beams : two types of different volume fraction of ER fluid and one type of different particle concentration of ER fluid by weight. Modal characteristics of the beams are observed in both the absence and the presence of electric potentials. It is also shown that by constructing active control algorithm the removal of structural resonances and the suppression of tip deflection are obtained. This result provides the feasiblility of ER fluids as an active vibration control element.