• Title/Summary/Keyword: compensator

Search Result 1,349, Processing Time 0.031 seconds

Design of Time Delay Compensator of Three-Level Inverter for Three-Phase UPS Systems (3상 UPS용 3레벨 인버터의 시지연 보상기 설계)

  • Lee, Jin-Woo;Lim, Seung-Beom;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.63-64
    • /
    • 2011
  • The inevitable calculation time delay of digital controller especially degrades the voltage control performance of three-phase UPS systems. This paper proposes time delay compensators based on the Smith-predictor for both voltage and current controllers of three-level NPC inverters. The PSIM-based simulation results show that the proposed controller with delay compensator gives improved voltage control performance with respect to time delay.

  • PDF

Analysis of Instantaneous Voltage Compensator Using 3-Phase PWM Inverter (3상 PWM 인버터를 이용한 순간전압보상기의 해석)

  • 최연규;이승요;최규하;목형수;함형원
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.222-227
    • /
    • 1997
  • Unbalanced source voltages due to unbalanced loads in the 3-phase power system is decomposed into positive, negative and zero sequence components. Also, assuming there is no neutural path in the system, the zero sequence component is not shown. Therefore, it is possible to compensate unbalanced source voltage by canceling the negative sequency component of the voltages of the source. In this paper, an algorithm compensating unbalanced source voltages by canceling the negative sequence component is presented and analysis of instantaneous voltage compensator using 3-phase PWM inverter is carried out through computer simulation.

  • PDF

DSP Control of Three-Phase UPS Inverter with Output Voltage Harmonic Compensator (3상 UPS 인버터의 출력전압 왜형률 개선을 위한 고조파 보상기법의 DSP 제어)

  • 변영복;조기연;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.269-275
    • /
    • 1997
  • This paper presents real time digital signal processor(DSP) control of UPS system feeding processor(DSP) control of UPS system feeding nonlinear loads to provide sinusoidal inverter output voltage. The control scheme is composed of an rms voltage compensator, the load current harmonics feed-forward loop for the cancellation of output voltage harmonics, and the output voltage harmonics feedback loop for system stability. The controller employs a Texas Instruments TMS320C40GFL50 DSP.

  • PDF

The Optimal Compensator for AT Forward Multi Resonant Converter

  • Oh Yong-Seung;Kim Hee-Jun;Kim Chang-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.242-246
    • /
    • 2001
  • The alternated forward multi resonant converter (AT forward MRC) is studied on the transient response and the measured loop gain for stability. The compensator is composed of the error amplifier with 3 poles and 2 zeros. This is optimized through the experiment with HP4194A network analyzer. We are initiated by the thinking of how to make the stabilization from the experimental results of loop gain curves. The loop gain, low frequency gain and gain margin are more improved through the experimental considerations. Also, the transient response is more enhanced effectively.

  • PDF

The Current Type Semiconductor Reactive Power Compensator Using Delta Modulation Method (델터변조방식을 이용한 전류형 반도체 무효전력보상장치)

  • Baek, Hyung-Lae;Kim, Han-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.443-446
    • /
    • 1991
  • In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the semiconductor reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is proposed in this paper and studied theoretically.

  • PDF

Current Control Method of Distribution Static Compensator Considering Non-Linear Loads (비선형 부하를 고려한 배전용 정지형 보상기의 전류제어 기법)

  • Kim, Dong-Geun;Choi, Jong-Woo;Kim, Heung-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1342-1348
    • /
    • 2009
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensated current and the other part is the current control. This paper proposes a proportional-resonant-repetitive current controller. Improved performance of instantaneous power compensation has been shown by simulations and experiments.

A Study on the Line-Interactive UPS with Power Factor correction (Line - Interactive UPS의 역률 개선 방안에 관한 연구)

  • Jang Hoon;Lee Woo-Cheol;Lee Taeck-Kie;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.93-96
    • /
    • 2001
  • This paper proposed on the Line-Interactive UPS with power factor correction. The paper Line-Interactive UPS topology with its advantages is reviewed. Next introduces Line -Interactive UPS of the series active compensator. The series active compensator controls input currents and power factor.

  • PDF

Disturbance Compensation Control by FXLMS Algorithm (FXLMS 알고리즘을 이용한 외란보상 제어기 설계)

  • 강민식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.100-107
    • /
    • 2003
  • This paper represents a disturbance compensation control for attenuating disturbance responses. In the consideration of the requirements on the model accuracy in the model based compensator designs, an experimental feed forward compensator design based on adaptive estimation by Filtered-x least mean square (FXLMS) algorithm is proposed. The convergence properties of the FXLMS algorithm are discussed and its conditions for the asymptotic convergence are derived theoretically. The effectiveness of the proposed method and the theoretical proof are verified by computer simulation.

Controller Design of Static Var Compensator Using Three Phase PWM Cuk AC-AC Converter (3상 PWM Cuk AC-AC 컨버터를 이용한 정지형 무효전력보상기의 제어기 설계)

  • Choi Nam-Sup
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.579-582
    • /
    • 2004
  • This paper presents controller design of a static var compensator using PWM Cuk AC-AC converter. The PWM Cuk AC-AC converter is modelled by using complex circuit DQ transformation and perturbed around the operating point whereby the small signal system characteristics is analytically obtained. Finally, the PSIM simulations show the validity of the modelling and analysis.

  • PDF