• Title/Summary/Keyword: communication cable

Search Result 439, Processing Time 0.023 seconds

Optimized Design of Mobile Communication Antenna In the Underground Area (지하공간에서의 이동통신 셀 설계에 관한 연구)

  • Oh, Sung-Kyun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • In the signals-shadowed areas, In order to providing the suitable signals reception level repeaters are used for relay the signals. Repeater receives the weak signals and amplifies it up to required power level, The amplified signals get radiated by the various methods. Both antenna distribution and LCX(Leakage Coaxial Cable) are typical methods in the repeater and BTS signals radiation. Their applications are depended on the environment condition and frequency band. Generally the antenna distribution are used for the mobile telecommunication networks which use the higher frequency band than 500MHz. On the other side, LCX distribution is suitable to the frequency band under 500MHz. The network plan of repeater in FM, T-DMB, Fire Radio and Internal subway communication network are the typical LCX application fields. Cell planning with repeaters are based on the free space loss, LCX connection loss and actual field data. The actual field data can be the most important factor to design the network planning.

Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable (6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정)

  • Park, Yong-Kyu;Cho, Young-Seek;Lee, Kwan-Woo;Um, Kee-Hong;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.

The State, Market, Media: Cable Television Industry Organization during the Early Stage of Kim Dae-Jung Administration (국가 정책의 성격 변화와 뉴미디어 산업의 조직: 김대중정부 초기의 케이블TV 산업을 중심으로)

  • Woo, Ji-Woon
    • Korean journal of communication and information
    • /
    • v.57
    • /
    • pp.137-159
    • /
    • 2012
  • This is a dissertation about the state and cable television industry relationship during the early days of Kim Dae-Jung administration(1998.2-2000.1) in Korea. This study adopted historical approach and methodology of archival research. Offe's state theories of reproduction of late capitalism and the concept of Korean patriarchal state-led capitalism were suggested in this paper. Offe argued that the goal of the late capitalist state is successful capital accumulation and democratic legitimation with bureaucratic rationalization. For this purpose, the state intervenes market structuring by various plans and national policies. The Kim Dae-Jung administration reorganized cable television market with neo-liberalistic strategies and corporatist forms of policy-making. The government negotiated capitalists and civil society for managing capitalistic economy and cable television market in a horizontal relationship. Successful consequences of the market growth resulted in generating mass loyalty. The former administrations to the contrary, invisibly arranged state-led capitalism was an only alternative to the Kim Dae-Jung administration. The Korean state-led capitalism evolved gradually into different forms.

  • PDF

EMC Design of Communication System on the Basis of EMC Design Rule (EMC Design Rule을 이용한 통신 System의 EMC Design)

  • 박학병;박종성;이승한;강석환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.77-83
    • /
    • 2001
  • We analyzed the mechanism of EM emission in telecommunication system and extracted the dominant parameter in EMC design. The I/O cable, ventilation hole and shield design of chassis are important EMC design Issues in telecommunication systems. Because telecommunication systems have much more I/O cables than other electronic products, EMC design of I/O cable is very important in telecommunication systems. Therefore by the method of experimentation and simulation, EM coupling mechanism of I/O cable was analyzed and the design rule for low emission was extracted. On the base of these EMC design rules, EMC design of telecommunication system was executed without complex redesign or debug. The result obtained by these methods was shown in this paper.

  • PDF

The Operation Status and Competitiveness Reinforcement Plan of Cable TV in Daejeon Area (대전지역 Cable TV의 운영현황 및 경쟁력 제고 방안)

  • Min, Hyoung-Hwan;Park, Soo-Yong;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.3
    • /
    • pp.115-122
    • /
    • 2022
  • As cable TV, which has been leading the paid broadcasting market, has given the lead to IPTV, which has huge communication capital, its competitiveness is gradually weakening. This study examines the operation status of local cable TV and seeks ways to strengthen competitiveness for survival. To this end, we conducted data analysis such as related statistics, broadcasting industry survey reports, IPTV growth reports, CMB management indicators, paid broadcasting literature data, marketing reports, industry success stories, and marketing mix and SWOT analysis. As a result, four strategies for strengthening the survival competitiveness of local cable TV, namely joint purchase apartment marketing strategy, influencer marketing strategy, relationship marketing strategy, and digital marketing strategy were derived. Therefore, the results of this study can contribute to the improvement of the competitiveness of local cable TV, which has been with local residents through close content, and can be used as basic data for establishing marketing strategies for local cable TV in the future.

Design of Submarine Cable for Capacity Extension of Power Line (전력선 용량증대를 위한 해저케이블 설계)

  • Son, Hong-Chul;Moon, Chae-Joo;Kim, Dong-Sub
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.77-84
    • /
    • 2022
  • A submarine power cable is a transmission cable for carrying electric power below the surface of the water. Recently, submarine cables transfer power from offshore renewable energy schemes to shore, e.g. wind, wave and tidal systems, and these cables are either buried in the seabed or lie on the ocean floor, depending on their location. Since these power cables are used in the extreme environments, they are made to withstand in harsh conditions and temperatures, and strong currents. However, undersea conditions are severe enough to cause all sorts of damage to offshore cables, these conditions result in cable faults that disrupt power transmission. In this paper, we explore the design criteria for such cables and the procedures and challenges of installation, and cable transfer splicing system. The specification of submarine cable designed with 3 circuits of 154kV which is composed of the existing single circuit and new double circuits, and power capacity of 100MVA per cable line. The determination of new submarine cable burial depth and cable arrangement method with both existing and new cables are studied. We have calculated the permission values of cable power capacity for underground route, the values show the over 100MW per cable line.

A Study on the Generation of the Earth Potential and Communication Line Noise (대지전위와 통신회선 잡음.발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.181-189
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

The Properties of Transmission in the High Foamed Coaxial Cable (고발포 동축케이블의 전송특성)

  • 김성탁;박대희;김용주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.77-80
    • /
    • 1998
  • Recently, extending the local broadcasting and increasing lots of informations. The low-loss communication cable is required in proportion as frequency .The reason of transportation loss causes to using the high frequencies like hundreds of MHz or decades of GHz. For the low transportation loss. It is required the developing-technology of foaming and the high foamed insulator with the dielectric ratio of the nearest to 1. Therefor, there is the purpose of developing the insulating materials for the low dielectric ratio. Also it is important to measure the attenuation, which is one of the important parameters.sa the evaluation of transportation characteristic with frequency in the communication cable. In this paper,the result showed that the dielectric ratio(1.4) of the nearest to 1 and low attenuation with high frequency were very related to the transportation and reflection characteristics such as propagation velocity (82.27%). Delay time and voltage standing wave ratio(VSWR).

  • PDF

A Study on the Analysis of Fire Hazards for Communication Cable (통신케이블의 화재위험성 분석에 관한 연구)

  • Hong, Sung-Ho;Park, Chan-Ho;Park, Sang-Tae;Yu, Song-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.192-194
    • /
    • 2009
  • This study presents on the analysis fire hazards of communication cable. In order to analyze fire hazards fire retardant tests and con-calorimeter test is conducted. The fire retardant tests are IEC 60332-1 and UL 94 test. The results show that IEC 60332-1 test and It 9t test are not effective to estimate fire hazard. And various parameter is obtained by con-calorimeter test. It is necessary to analysis effectively fire hazards of cable for new fire retardant test.

  • PDF