• Title/Summary/Keyword: commercially pure titanium(CP Ti)

Search Result 32, Processing Time 0.025 seconds

Evaluation of press formability of pure titanium sheet (순 티탄늄 판재의 프레스 성형성 평가(제 1보))

  • Kim, Young-Suk;In, Jeong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.380-388
    • /
    • 2016
  • Commercially pure titanium (CP Ti) has been actively used in plate heat exchangers due to its light weight, high specific strength, and excellent corrosion resistance. However, compared with automotive steels and aluminum alloys, there has not been much research on the plastic deformation characteristics and press formability of CP Ti sheet. In this study, the mechanical properties of CP Ti sheet are clarified in relation to press formability, including anisotropic properties and the stress-strain relation. The flow curve of the true stress-true strain relation is fitted well by the Kim-Tuan hardening equation rather than the Voce and Swift models. The forming limit curve (FLC) of CP Ti sheet was experimentally evaluated as a criterion for press formability by punch stretching tests. Analytical predictions were also made via Hora's modified maximum force criterion. The predicted FLC with the Kim-Tuan hardening model and an appropriate yield function shows good correlation with the experimental results of the punch stretching test.

Electrochemical Approach on the Corrosion During the Cavitation of Additive Manufactured Commercially Pure Titanium (적층가공 방식으로 제조된 CP-Ti의 캐비테이션 중 부식에 대한 전기화학적 접근)

  • Kim, K.T.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.310-316
    • /
    • 2018
  • The effect of passive film on corrosion of metals and alloys in a static corrosive environment has been studied by many researchers and is well known, however few studies have been conducted on the electrochemical measurement of metals and alloys during cavitation corrosion conditions, and there are no test standards for electrochemical measurements 'During cavitation' conditions. This study used commercially additive manufactured(AM) pure titanium in tests of anodic polarization, corrosion potential measurements, AC impedance measurements, and repassivation. Tests were performed in 3.5% NaCl solution under three conditions, 'No cavitation', 'After cavitation', and 'During cavitation' condition. When cavitation corrosion occurred, the passive current density was greatly increased, the corrosion potential largely lowered, and the passive film revealed a small polarization resistance. The current fluctuation by the passivation and repassivation phenomena was measured first, and this behavior was repeatedly generated at a very high speed. The electrochemical corrosion mechanism that occurred during cavitation corrosion was based on result of the electrochemical properties 'No cavitation', 'After cavitation', and 'During cavitation' conditions.

Effect of Manufacturing Process on Electrochemical Properties of CP-Ti and Ti-6Al-4V Alloys (CP-Ti 및 Ti-6Al-4V 합금의 전기화학적 특성에 미치는 제조공정의 영향)

  • Kim, K.T.;Cho, H.W.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • Ti and its alloys show the excellent corrosion resistance to chloride environments, but they show less corrosion resistance in HCl, $H_2SO_4$, NaOH, $H_3PO_4$, and especially HF environments at high temperature and concentration. In this study, we used the commercially pure titanium and Ti-6Al-4V alloy, and evaluated the effect of the manufacturing process on the electrochemical properties. We used commercial products of rolled and forged materials, and made additive manufactured materials by DMT (Directed Metal Tooling) method. We annealed each specimen at $760^{\circ}C$ for one hour and then air cooled. We performed anodic polarization test, AC impedance measurement, and Mott-Schottky plot to evaluate the electrochemical properties. Despite of the difference of its microstructure of CP-Ti and Ti-6Al-4V alloys by the manufacturing process, the anodic polarization behavior was similar in 20% sulfuric acid. However, the addition of 0.1% hydrofluoric acid degraded the electrochemical properties. Among three kinds of the manufacturing process, the electrochemical properties of additive manufactured CP-Ti, and Ti-6Al-4V alloys were the lowest. It is noted that the test materials showed a Warburg impedance in HF acid environments.

The Effect of Microstructural Evolution on Corrosion Property of Ti Plate with Heat Treatment (열처리에 따른 미세구조 변화가 Ti 판재의 부식특성에 미치는 영향)

  • Kim, Min Gyu;Lee, Chan Soo;Kim, Tae Gyu;Kim, Hye Sung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.1
    • /
    • pp.12-17
    • /
    • 2018
  • We investigated the corrosion behavior of commercially pure cold working processed (CP)-Ti with coarse-grained (CG) microstructure heat-treated at $400^{\circ}C$ and $600^{\circ}C$, respectively. It is observed that corrosion resistance of as-received CP-Ti heat-treated at $400^{\circ}C$, at which recrystallization proceeds, is largely improved. Interestingly, the mechanical property of CP-Ti sample at $400^{\circ}C$ was scarcely deteriorated. It is attributed to the decrease of the defects such as strain variance and dislocation density. On the other hand, the annealing treatment at $600^{\circ}C$ of CP-Ti plate causes to grain growth with the noticeable reduction of mechanical property. Hence, it is considered that defect density such as strain and dislocation density is important microstructural parameter for the improvement of corrosion resistance. The introduction of proper annealing treatment can help to improve corrosion resistance without scarifying mechanical property of CP-Ti.

Effects of Cooling Method Followed by Casting on the Interfacial and Mechanical Properties of Dental CP-Ti Casts (치과용 티타늄 주조체의 냉각방법이 표면반응층 및 기계적 특성에 미치는 영향)

  • Moon, Soo;Jung, Jun-Young;Kim, Ki-Ju;Lee, Jin-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.375-380
    • /
    • 2003
  • In this study. we have intended to control the properties of surface reaction zone generated between pure titanium and oxide investment moulds. Commercially pure titanium was centrifugally casted and silica$.$alumina based phosphate bonded investment was used as the mould material. The effect of cooling methods after casting on the surface reaction zone and mechanical properties of casts were investigated. The resulting casts showed the multilayered surface reaction zone regardless of cooling method. Especially. water cooling method produced the titanium casts with thinner surface reaction zone. weaker strength. and higher elongation properties compared to air cooling. It can thus be known that the resulting casts had satisfactory mechanical properties as dental materials. From these results, the cooling rate dependence of interfacial and mechanical properties can be attributed to the diffusion of oxygen from casting environment, which control the reaction of titanium and mould.

Effect of Hydrofluoric Acid on the Electrochemical Properties of Additive Manufactured Ti and Its Alloy (적층가공된 티타늄 합금의 전기화학적 특성에 미치는 불산의 영향)

  • Kim, K.T.;Cho, H.W.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.166-175
    • /
    • 2018
  • In this study, the electrochemical properties of CP-Ti (commercially pure titanium) and Ti-64 (Ti-6Al-4V) were evaluated and the effect of hydrofluoric acid on corrosion resistance and electrochemical properties was elucidated. Additive manufactured materials were made by DMT (Directed Metal Tooling) method. Samples were heat-treated for 1 hour at $760^{\circ}C$ and then air cooled. Surface morphologies were studied by optical microscope and SEM. Electrochemical properties were evaluated by anodic polarization method and AC-impedance measurement. The oxide film formed on the surface was analyzed using an XPS. The addition of HF led to an increase in the passive current density and critical current density and decreased the polarization resistance regardless of the alloys employed. Based on the composition of the oxide film, the compositional difference observed by the addition of HF was little, regardless of the nature of alloys. The Warburg impedance obtained by AC-impedance measurement indicates the dissolution of the constituents of CP-Ti and Ti-64 through a porous oxide film.

Prediction of Cryogenic- and Room-Temperature Deformation Behavior of Rolled Titanium using Machine Learning (타이타늄 압연재의 기계학습 기반 극저온/상온 변형거동 예측)

  • S. Cheon;J. Yu;S.H. Lee;M.-S. Lee;T.-S. Jun;T. Lee
    • Transactions of Materials Processing
    • /
    • v.32 no.2
    • /
    • pp.74-80
    • /
    • 2023
  • A deformation behavior of commercially pure titanium (CP-Ti) is highly dependent on material and processing parameters, such as deformation temperature, deformation direction, and strain rate. This study aims to predict the multivariable and nonlinear tensile behavior of CP-Ti using machine learning based on three algorithms: artificial neural network (ANN), light gradient boosting machine (LGBM), and long short-term memory (LSTM). The predictivity for tensile behaviors at the cryogenic temperature was lower than those in the room temperature due to the larger data scattering in the train dataset used in the machine learning. Although LGBM showed the lowest value of root mean squared error, it was not the best strategy owing to the overfitting and step-function morphology different from the actual data. LSTM performed the best as it effectively learned the continuous characteristics of a flow curve as well as it spent the reduced time for machine learning, even without sufficient database and hyperparameter tuning.

Surface Characteristics and Biocompatibility of Titanium Coated with Dentin-derived Hydroxyapatite

  • Kim, Hae-Jin;Son, Mee-Kyung;Lee, Kyung-Ku;Lee, Bo-Ah;Kim, Young-Joon
    • International Journal of Oral Biology
    • /
    • v.37 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • The aim of this study was to evaluate surface characteristics and biological properties of the dentin -derived hydroxyapatite (HA) coating on titanium substrate. Dentinderived HA was obtained from extracted human teeth using a calcination method at $850^{\circ}C$. The commercially pure titanium (cp-Ti, ASTM Grade II) was used as a metallic substrate and a radio frequency magnetron sputtering method was employed as a coating method. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) were utilized to investigate the coating aspects and composition. Atomic forced microscopy (AFM) and a surface profiler were used to assess the surface morphology and roughness. Corrosion tests were performed in phosphate-buffered saline at a $36.5{\pm}1^{\circ}C$ in order to determine the corrosion behavior of the uncoated and coated specimens. The biocompatibility of dentin-derived HA coated specimens with fetal rat calvarial cells and human gingival fibroblasts was assessed by SEM and cell proliferation analysis. The results showed that the dentin-derived HA coatings appeared to cover thinly and homogeneously the surfaces without changing of the titanium substrate. The EDX analysis of this the coating surface indicated the presence of Ca and P elements. The mean surface roughness of cp-Ti and dentin-derived coating specimens was $0.27{\mu}m$ and, $1.7{\mu}m$, respectively. Corrosion tests indicated a stable passive film of the dentin-derived HA coating specimens. SEM observations of fetal rat calvarial cells and human fibroblast cells on coated surfaces showed that the cells proliferated and developed a network of dense interconnections. The cells on all specimens proliferated actively within the culture period, showing good cell viability. At day 1 and 3, dentin-derived coating specimens showed 89% and 93% cell viability, respectively, when normalized to cp-Ti specimens. These results suggest that dentin-derived HA coating using the RF magnetron sputtering method has good surface characteristics and biocompatibility.

Surface Apatite Growth of NaOH and SBF Treated CP-Ti, Ti-6Al-4V and ECAP-Ti (NaOH처리와 SBF침적에 따른 CP-Ti, Ti-6Al-4V 및 ECAP-Ti의 표면 아파타이트 성장)

  • Oh Seok-Jin;Ruy Jae-Gyeoung;Lee Seung-Woo;Kim Yun-Jong;Han Man-So;Kim Chang-Hyu
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.893-899
    • /
    • 2004
  • Even though Ti-6Al-4V has gained popularity as an implant material, the possible dissolution of Al and V ions in body fluids remains a matter of concern. Though commercially pure Ti (Cp-Ti) overcomes this problem, the mechanical strength of pure titanium remains very low. Thus, in this experiment Cp-Ti was processed by Equal channel angular processing (ECAP), in order to increase the mechanical strength. The biocompatibility of ECAP-Ti, Cp-Ti and Ti-6Al-4V was examined by the apatite formation on each sample surface, after treating the surface with 5M NaOH and soaking in Simulated body fluids (SBF). Initially, the samples were mechanically polished on silicone carbide paper (#2000). The polished samples were treated with 5M NaOH solution at $60^{\circ}C$ for 24 hours. The NaOH treated samples were washed gently with distill water and dried at $40^{\circ}C$ for 1 day. The dried samples were heat treated in air at $600^{\circ}C$ for 1 hour. The surface morphology of these samples were studied using SEM and XRD. The SEM studies showed network of pores in all samples. The XRD showed oxide layer formation on Cp-Ti and Ti-6Al-4V. samples. However the oxide layer in ECAP-Ti was not substantial. These samples were immersed in SBF, kept at $36.5^{\circ}C$ for seven days period. At the end of 7 days, the apatite formation was confirmed only on Cp-Ti and was not observed in Ti-6Al-4V and ECAP-Ti. These observations of apatite formation relate to the fact that Cp-Ti showed greater oxide layer than other samples. The apatite examined was confirmed as tricalcium phosphate (TCP) using EDS and XRD.

Electrochemical Behaviors of PEO-treated Ti-6Al-4V Alloy in Solution Containing Zn and Si Ions

  • Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.160-160
    • /
    • 2017
  • Commercially pure titanium (Cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Plasma electrolyte oxidation (PEO) enables control in the chemical composition, porous structure, and thickness of the TiO2 layer on Ti surface. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study on electrochemical behaviors of PEO-treated Ti-6Al-4V Alloy in solution containing Zn and Si ions. The morphology, the chemical composition, and the microstructure analysis of the sample were examined using FE-SEM, EDS, and XRD. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat. The promising results successfully demonstrated the immense potential of Si/Zn-TiO2 coatings in dental and biomaterials applications.

  • PDF