Browse > Article
http://dx.doi.org/10.3740/MRSK.2004.14.12.893

Surface Apatite Growth of NaOH and SBF Treated CP-Ti, Ti-6Al-4V and ECAP-Ti  

Oh Seok-Jin (Korea Atomic Energy Research Institute)
Ruy Jae-Gyeoung (Department of Materials Engineering, Graduate school of Paichai University)
Lee Seung-Woo (Department of Materials Engineering, Graduate school of Paichai University)
Kim Yun-Jong (Department of Materials Engineering, Graduate school of Paichai University)
Han Man-So (Dept. of Dental Laboratory Technology, Daejeon Health Science College)
Kim Chang-Hyu (Korea Atomic Energy Research Institute)
Publication Information
Korean Journal of Materials Research / v.14, no.12, 2004 , pp. 893-899 More about this Journal
Abstract
Even though Ti-6Al-4V has gained popularity as an implant material, the possible dissolution of Al and V ions in body fluids remains a matter of concern. Though commercially pure Ti (Cp-Ti) overcomes this problem, the mechanical strength of pure titanium remains very low. Thus, in this experiment Cp-Ti was processed by Equal channel angular processing (ECAP), in order to increase the mechanical strength. The biocompatibility of ECAP-Ti, Cp-Ti and Ti-6Al-4V was examined by the apatite formation on each sample surface, after treating the surface with 5M NaOH and soaking in Simulated body fluids (SBF). Initially, the samples were mechanically polished on silicone carbide paper (#2000). The polished samples were treated with 5M NaOH solution at $60^{\circ}C$ for 24 hours. The NaOH treated samples were washed gently with distill water and dried at $40^{\circ}C$ for 1 day. The dried samples were heat treated in air at $600^{\circ}C$ for 1 hour. The surface morphology of these samples were studied using SEM and XRD. The SEM studies showed network of pores in all samples. The XRD showed oxide layer formation on Cp-Ti and Ti-6Al-4V. samples. However the oxide layer in ECAP-Ti was not substantial. These samples were immersed in SBF, kept at $36.5^{\circ}C$ for seven days period. At the end of 7 days, the apatite formation was confirmed only on Cp-Ti and was not observed in Ti-6Al-4V and ECAP-Ti. These observations of apatite formation relate to the fact that Cp-Ti showed greater oxide layer than other samples. The apatite examined was confirmed as tricalcium phosphate (TCP) using EDS and XRD.
Keywords
ECAP; apatite; SBF; NaOH;
Citations & Related Records
연도 인용수 순위
  • Reference
1 H. M. Kim, F. Miyaji, T. Kokubo, S. Nishiguchi and T. Nakamura, John Wiley & Sons, Inc. 100 (1999)   DOI   ScienceOn
2 D. H. Shin, I. Kim, J. Kim, Y. S. Kim and S. L. Semiatin, Acta Materials 51, 983 (2003)   DOI   ScienceOn
3 V. V. Stolyarov, Y. T. Zhu, I. V. Alexandrov, T. C. Lowe and R. Z. Valiev, Materials Science and Engineering, A299, 59 (2001)   DOI   ScienceOn
4 Y. Iwahashi, Z. Horita, M. Nemoto and T. G. Langdon, Acta Mater. 46, 3317 (1998)   DOI   ScienceOn
5 D. J. Lin, J. H. Chem Lin and C. P. Ju, Biomaterials, 23, 1723 (2002)   DOI   ScienceOn
6 H. B. Wen, J. G. C. Wolke, J. R. de Wijn, Q. Liu and F. Z. Cui, Biomaterials, 18, 1471 (1997)   DOI   ScienceOn
7 H. B. Wen, Q. Liu, J. R. de Wijn, K. DE Groot, J. Mat. sci, materials in medicine, 9, 121 (1998)   DOI   ScienceOn
8 J. Ma, H. Wong, L. B. Kong and K. W. Peng, Nanotechnology, 14, 619 (2003)   DOI   ScienceOn
9 B. H. Lee, Y. D. Kim and K. H. Lee, Biomaterials, 24 2257 (2003)   DOI   ScienceOn
10 J. B. Park and R. S. Lakes, 'Biomaterials An Introduction', 89, Kluwer Academic Publishers, New York and London, (1992)
11 H. M. Kim, F. Miyaji, T. Kokubo and T. Nakamura, John Wiley & Sons, Inc, 38, 121 (1997)   DOI   ScienceOn