• 제목/요약/키워드: column-slab joint

검색결과 57건 처리시간 0.019초

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

An experimental study of the behaviour of double sided bolted billet connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.603-622
    • /
    • 2018
  • Precast concrete structures are erected from individual prefabricated components, which are assembled on-site using different types of connections. In the present design of these structures, beam-to-column connections are assumed pin jointed. Bolted billet beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is currently limited information concerning their detailed structural behaviour under vertical loadings. The experimental work has involved the determination of moment-relative rotation relationships for semi-rigid precast concrete connections in full-scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and bolt arrangements conformed to successful commercial practice. Proprietary hollow core floor slabs were tied to the beams by 2T25 tensile reinforcing bars, which also provide the in-plane continuity across the connections. The contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. The flexural strength of the connections in the double-sided tests was at least 0.93 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.94 to 1.94 times the flexural stiffness of the attached beam. In general, the double-sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided bolted billet connection test results are presented in this paper. The behaviour of single sided bolted billet connection test results is the subject of another paper.

Experimental investigation of the behaviour of a steel sub-frame under a natural fire

  • Santiago, Aldina;Simoes da Silva, Luis;Vaz, Gilberto;Vila Real, Paulo;Lopes, Antonio Gameiro
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.243-264
    • /
    • 2008
  • This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.

PT 플랫 플레이트와 RC 플랫 플레이트 내부 접합부의 구조적 거동 비교에 관한 실험적 연구 (An Experimental Study on Comparison of Structural Behavior of PT Flat Plate and RC Flat Plate Interior Connections)

  • 이동근;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.111-114
    • /
    • 2005
  • While the existing reinforced concrete flat plate(RC flat plate) has a lot of advantages including reduced building height, it has some weak points such as many steel bars and the brittle rupture by punching shear. Compared with the RC flat plate, the post-tensioned flat plate (PT flat plate) has not only the same merits, but it also makes longer span possible and induces slab-column connections to be failed with the ductile behavior rather than with the brittle behavior by means of post-tensioning. However, it is difficult to define the joint behavior of PT flat plate under vertical and lateral loads since there are limit experimental results. For this reason, the experimental study is undertaken to investigate the comparison of behavior of PT flat plate and RC flat plate, and how flat plate(Gravity Load Resisting System) is displaced as lateral loads, like the wind and the earthquake, are occur. The result of this experiment shows that PT flat plate is generally superior to RC flat plate in terms of controlling crack, postponing stiffness deterioration, energy dissipation, etc.

  • PDF

중력전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진 성능 평가 (Seismic Performance of Reinforced Concrete Flat Plate Frames according to Gravity Shear Ratio)

  • 황보진;한상환;박영미
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.3-10
    • /
    • 2010
  • 이 연구에서는 중력 전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진성능을 평가하였다. 이를 위하여, 이 연구에서는 3층, 7층 골조를 중력하중만 고려하여 설계하고, 대상 건물에 대한 비선형 정적 푸쉬 오버 해석과 비선형 동적 해석을 수행하였다. 그리고 이 연구는 그 비선형 해석에서 중력 전단비의 차이에 따른 뚫림 전단과 파괴 메커니즘을 예측할 수 있도록 제안한 슬래브-기둥 접합부 모델을 사용하였다. 이 연구 결과에 따르면 중력 전단비가 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 중력 전단비가 커짐에 따라 골조 접합부의 파괴가 취성적인 파괴를 나타내어 내진 성능이 떨어지는 것으로 나타났다.

BIM기반 초기 설계 단계 철근 물량 산출 프로세스 구축 (Establishment of Rebar Quantity Estimation in BIM-based Initial Design Phase)

  • 송치호;김치경;이시은;최현철
    • 한국전산구조공학회논문집
    • /
    • 제29권5호
    • /
    • pp.447-454
    • /
    • 2016
  • 최근에 각광받고 있는 3D BIM기반 철근 물량 산출 현황을 살펴보면 상용 BIM 도구들이 철근 모델링 기능을 제공하지만 그 기능을 이용해서 철근을 모델링하려고 하면 방대한 양의 모델링 시간이 소요가 되어 현재 실용적으로 사용할 수 있는 BIM 소프트웨어는 없다. 본 연구에서는 BIM 기반 설계 현업에서 실용적인 철근 물량 산출 프로세스를 정리 및 제시하고, 초기설계단계의 단면 정보가 없는 상태에서 기존의 2D방식에 비하여 보다 정확하게 기동, 보, 슬래브, 벽체의 철근 단면 정보를 자동으로 배근해주는 프로그램인 Rebar Automatic Arrangement Program(이하 RAAP)을 개발하였다. 본 연구 결과는 건설프로젝트의 초기 설계단계에서 설계 진행상 구조 부재 단면 설계가 완료되지 않은 상태의 골조 물량 산출 시 적은 노력으로 기존의 2D기반 방식보다 신뢰성을 향상시킨 물량을 산출할 수 있는 기술로 발전시키는데 의미가 있으며, 합리적인 초기 설계단계의 물량 산출 프로그램을 구축할 수 있는 기초 연구로서 활용될 수 있을 것으로 기대된다.

콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능 (Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections)

  • 박창희;이철호;박홍근;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.503-514
    • /
    • 2011
  • 본 연구에서는 콘크리트채움 U형 합성보와 H형강 기둥 십자형 합성접합부의 내진상세를 제시하고, 2개의 실물대 실험체를 설계/제작하여 강구조내진기준의 표준실험절차에 따라 내진성능을 평가하였다. 주요 실험체 구성요소는 춤 450mm(실험체 A) 및 550mm(실험체 B) U형 강재보, 두께 165mm의 골데크플레이트 위에 타설된 콘크리트 바닥슬래브, U형보의 완전합성작용을 하기 위한 전단스터드, 부모멘트 전달을 위한 4개의 주철근 및 H형강 기둥에 정착을 위한 용접커플러 그리고 접합부 보강을 위한 보강판으로 구성된다. 순수 강재 보-기둥 접합부와 상이한 U형 합성접합부의 독특한 특성을 고려하여, 지진하중 하에서 내진성능에 결정적 영향을 미치는 보-기둥 접합부의 용접부 취성파단, 강판의 국부좌굴, 주철근의 휨좌굴, 콘크리트 압괴 등의 한계상태가 적절히 제어되도록 실험체를 설계하였다. 강구조내진기준의 지진하중 가력프로그램에 따른 실험결과, 설계에서 의도한 바와 같이 여러 한계상태가 적절히 제어되어 실험체 A 및 B는 각각 6% 및 6.8% 라디안에 이르는 매우 뛰어난 층간변형능력을 발휘하였다. 이는 특수모멘트골조에 요구되는 4% 라디안 수준을 충분히 상회하는 만족스런 층간변형능력이다. 특히 접합부 강화전략에 의해 제안된 합성접합부 상세는 설계에서 의도한 것과 같이 소성힌지를 보강단부로서 밀어냄으로서 취약할 수 있는 보-기둥 용접접합부를 효과적으로 보호하였다. 실험체 A의 최종 파괴모드는 6.0% 층간변위에서 발생한 보강단부에 인접한 냉간성형 코너부의 점진적 저사이클피로에 의한 하부플랜지의 파단에 의해 발생하였다. 한편, 실험체 B는 8.0%의 높은 수준의 층간변위에서 발생한 볼트이음부 파단에 의해 내력을 상실하였다.