DOI QR코드

DOI QR Code

Experimental investigation of the behaviour of a steel sub-frame under a natural fire

  • Received : 2008.12.01
  • Published : 2008.06.25

Abstract

This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.

Keywords

References

  1. ECSC project 7210, 2000 "Natural fire safety concept. Full Scale tests, Implementation in the Eurocodes and Development of an User-friendly Design Tool". ECSC project 7210-PA/PB/PC/PD/PE/PF/PR-060, 1997-2000.
  2. Leston-Jones, L.C., Burgess, I.W., Lennon, T., Plank, R.J., "Elevated-temperature moment-rotation tests on steelwork connections", Proc. Instn Civil Engrs, Structures & Buildings, 122, pp. 410-419, 1997. https://doi.org/10.1680/istbu.1997.29830
  3. Liu, T.C.H., Fahad, M.K. and Davies, J.M., "Experimental investigation of behaviour of axial restrained steel beams in fire", J. Constr. Steel Res., 58, 1211-1230, 2002. https://doi.org/10.1016/S0143-974X(01)00062-1
  4. Santiago, A., Simoes da Silva, L. and Vila Real, P., "Effect of cooling on the behaviour of a steel beam under fire loading including the end joint response", Proceedings of 9th International Conference on Civil and Structural Engineering Computing, Egmond-aan-Zee, Nederlands, September 2-4, 2003.
  5. Simões da Silva, L., Santiago, A. and Vila Real, P. "A component model for the behaviour of steel joint at elevated temperatures", J. Constr. Steel Res. 57(11), pp. 1169-1195, 2002.
  6. Simões da Silva, L. Santiago, A., Vila Real, P. and Moore, D.B., "Behaviour of steel joints under fire loading", Steel Compos. Struct. 6, 485-513, 2005.
  7. Trinks W., Mawhinney, M.H., Shannon, R.A., Reed, R.J and Garvey, J.R., Industrial Furnaces, 6th edition, John Wiley & Sons, Inc., 2004.
  8. Wald, F, Simões da Silva, L., Moore, D., Lennon, T., Chladna, M., Santiago, A., Benes, M., and Borges, L., "Experimental behaviour of a steel structure under natural fire", Fire Safety J., 41(7), pp. 509-522, 2006. https://doi.org/10.1016/j.firesaf.2006.05.006
  9. Wang, Y.C., Steel & Comp. Struct - behaviour and design for fire safety, Spon Press, London, 2002.
  10. Vila real, P.M.M., Piloto, P.A.G. and Franssen, J.-M.; "A new proposal of a simple model for lateral-torsional buckling of unrestrained steel i-beams in case of fire: experimental and numerical validation". J. Constr. Steel Res., 59(2), 179-199, 2003. https://doi.org/10.1016/S0143-974X(02)00023-8

Cited by

  1. Numerical Modelling of the Influence of Joint Typologies on the 3D Behaviour of a Steel Sub-Frame Under a Natural Fire vol.46, pp.1, 2010, https://doi.org/10.1007/s10694-009-0099-3
  2. Fire response of steel column-tree moment resisting frames vol.48, pp.6, 2015, https://doi.org/10.1617/s11527-014-0271-1
  3. Behavior of beams in bolted column-tree frames at elevated temperature vol.40, pp.3, 2016, https://doi.org/10.1002/fam.2305
  4. Parametric study of anti-explosion performance of reinforced concrete T-shaped beam strengthened with steel plates vol.156, 2017, https://doi.org/10.1016/j.conbuildmat.2017.08.150
  5. Plastification procedure of laterally-loaded steel bars under a rising temperature vol.35, pp.6, 2010, https://doi.org/10.12989/sem.2010.35.6.699
  6. Numerical assessment of T-stub component subjected to impact loading vol.106, 2016, https://doi.org/10.1016/j.engstruct.2015.10.047
  7. CRITICAL TEMPERATURE OF STEEL BEAMS ON THE BASIS OF A LOAD-BEARING FIRE TEST OF 2-STOREY RIGID STEEL FRAME vol.79, pp.704, 2014, https://doi.org/10.3130/aijs.79.1559
  8. Integrated fire dynamics and thermomechanical modeling framework for steel-concrete composite structures vol.10, pp.2, 2008, https://doi.org/10.12989/scs.2010.10.2.129
  9. STRESS AND DEFORMATION BEHAVIOR OF FRICTION TYPE HIGH STRENGTH BOLTED JOINTS DURING COOLING PHASE IN FIRE vol.84, pp.759, 2019, https://doi.org/10.3130/aijs.84.749
  10. Behavior of fluorine coatings on steel bridges at different temperatures upon exposure to a direct heat source vol.97, pp.None, 2008, https://doi.org/10.1016/j.jiec.2021.02.026
  11. Fire Response of Steel Column Trees with End-Plate Connections vol.147, pp.10, 2021, https://doi.org/10.1061/(asce)st.1943-541x.0003139
  12. Development of Passive Fire Protection Mortars vol.12, pp.4, 2008, https://doi.org/10.3390/app12042093