• Title/Summary/Keyword: column-slab

Search Result 288, Processing Time 0.022 seconds

Experimental investigation of the behaviour of a steel sub-frame under a natural fire

  • Santiago, Aldina;Simoes da Silva, Luis;Vaz, Gilberto;Vila Real, Paulo;Lopes, Antonio Gameiro
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.243-264
    • /
    • 2008
  • This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.

Analysis of Seismic Performance of Slim Flat Plate System in High-rise Hybrid Structural System (슬림형 바닥시스템을 이용한 고층 복합구조의 내진성능에 관한 해석적 연구)

  • Ha Gee Joo;Park Hyo Sun;Park Joung Hyen;Choi Kyung Ryeol;Kim Dae Joung;Jung Jea Kwang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.77-80
    • /
    • 2005
  • Recently the construction of high-rise hybrid type building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new hybrid structural system, using slim flat plate system, is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is ,with the economy and flexibility, flat plate system in high-rise hybrid type building. But it was focused in the seismic performance for high performance flat plate system in high-rise hybrid type building. Therefore, in the study, to develop the new flat-plate system with high ductile, durable, good performance for the applications. It was evaluated the seismic performance in the critical region of slab-column connection. And then high performance flat plate system, designed by the economy and safety, was developed as a new technique in the application of high-rise hybrid type building.

  • PDF

Representation of Rebar using IFC at Schematic Structural Design Stage (기술초대석 I - IFC를 이용한 기본설계단계 철근배근의 표현)

  • Jeong, Jong-Hyeon;Kim, Chi-Gyeong;Kim, Ji-Hyeon
    • 건축구조
    • /
    • v.19 no.4
    • /
    • pp.51-60
    • /
    • 2012
  • In recent years, BIM has been applied to many building projects. However, IFC, which is the core technology of data exchange in BIM, has not been used widely. In particular, IFC has almost never been used to represent rebars in RC structures. This is because the lack of understanding and utilization strategy for data model of IFC on rebars. The purpose of this study is to store and manage the data on rebars using IFC at the schematic design stage. For this, we investigated the data to represent rebars for RC members, such as beam, column, wall, and slab at the schematic design stage. And, we analyzed the data model of IFC on rebars at the schematic design stage. Based on these investigation and analysis on data, we proposed the strategy for utilization of the data model of IFC on rebars. Finally, for verification, we generated a sample IFC file to represent the rebars of a simple RC structure according to the proposed strategy and imported the sample IFC file into the software, which we developed for this study. Based on the results of the import, we concluded that the data on rebars can be stored and managed using the proposed strategy for utilization of the data model of IFC on rebars.

  • PDF

A Study on The Modulor System Shown in Structure and Envelope of Le Corbusier's Works (Le Corbusier 건축의 구조와 외피에 나타나는 모듈러 시스템에 관한 연구)

  • Cho, Sung-Hyun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.10 no.1
    • /
    • pp.15-22
    • /
    • 2010
  • As for structural system, which constitutes his construction, there are column inside dimension and span which constitutes plane, and as for constructions for section, there are C.H and slab, and as for constructive factors for envelope, there are window and closing panel of outer wall, and as for opening, there are punching window and wave window. With these constructive parts and opening of envelope, his construction composes volume and mass. The relation of structure and modulor which are shown in his later construction can be divided in two cases that modulor is directly and indirectly adapted for rate and measure calculation of the constructive body. As for indirectly adapted case, we can find it form most of his later construction, it is living place in which human beings life is, and it is adapted mainly for small space. In his construction, he tried to tell human scale and sense of musical rhythm through modulor. In other words, he played sense of space and musical scale by adapting regular and repetitive modulor of opening, and in small space for daily life, he made the size of space into the space which human can perceive. And, if we interpret mudulor in modern meaning, it is an establishment of radius of human act. And, we can make organic and harmonic design of space if we use modulor as origin of human centered measurement calculation, and if we adapt space after dividing by use.

A Study on Optimum Section of New Type Steel-Concrete Composite Beam (신형상 층고절감형 합성보의 최적단면 도출에 관한 연구)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.30-35
    • /
    • 2011
  • This study investigates the optimum section properties of newly developed steel-concrete composite beam. For that purpose we developed computer program calculating section properties. The suggested new beam section highly contribute to save inter-story height and reduce construction duration and cost compared with conventional steel works such as H-beam and column + RC slab system. But the section shape have different section modulus with upper and lower fiber because of the unsymmetric cross section. Therefore the parametric study on thickness-ratio of top and bottom flange plate is needed. In this paper the change of neutral axis and section modulus for thickness-ratio of up and down flage plate is analysed and discussed.

An Experimental Study on Comparison of Structural Behavior of PT Flat Plate and RC Flat Plate Interior Connections (PT 플랫 플레이트와 RC 플랫 플레이트 내부 접합부의 구조적 거동 비교에 관한 실험적 연구)

  • Lee Dong Keun;Ha Sang-Su;Han Sang Whan;Lee Li Ryung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.111-114
    • /
    • 2005
  • While the existing reinforced concrete flat plate(RC flat plate) has a lot of advantages including reduced building height, it has some weak points such as many steel bars and the brittle rupture by punching shear. Compared with the RC flat plate, the post-tensioned flat plate (PT flat plate) has not only the same merits, but it also makes longer span possible and induces slab-column connections to be failed with the ductile behavior rather than with the brittle behavior by means of post-tensioning. However, it is difficult to define the joint behavior of PT flat plate under vertical and lateral loads since there are limit experimental results. For this reason, the experimental study is undertaken to investigate the comparison of behavior of PT flat plate and RC flat plate, and how flat plate(Gravity Load Resisting System) is displaced as lateral loads, like the wind and the earthquake, are occur. The result of this experiment shows that PT flat plate is generally superior to RC flat plate in terms of controlling crack, postponing stiffness deterioration, energy dissipation, etc.

  • PDF

A Study on the Adaptable Long Life Multi-dwelling Housing Design in Korea (융통성을 고려한 장수명 공동주택 디자인에 관한 연구)

  • Kim, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.172-177
    • /
    • 2006
  • Most of the Korean multi-dwelling houses have less than 20 years of lifespan. Because the environmental issues such as energy consumption, limited resources, and demolition waste problems became been more and more critical, we now need to focus on long lasting and adaptable buildings. Korean wall bearing apartment buildings are constructed with site cast concrete for core, exterior, and interior together with pipes varied, so when the buildings are old and life style of the users changes, it is difficult to maintain and renovate these buildings. In this study, to resolve the problems described above, two types of Korean long life multi-dwelling housing models which represent improved durability and adaptability responding user's needs and life style changes were proposed with various methods as follows: Either column and beam structure or flat slab structure was used to utilize space better. To make maintenance easier and renovation economical for both public space and each unit, plumbing pipes, ducts, and conduits were clustered at the cores and public corridors with access doors and light weight partitions with steel studs and raised floors or above-ceiling spaces were used in lieu of site cast concrete walls and floor slabs with varied pipes.

Algorithm for the Reinforced Concrete Framework Materials Take-off (철근콘크리트조의 골조물량산출 알고리즘)

  • Kim Tae-Hui;Hong Chae-Gon;Kim Sun-Kuk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.1 s.13
    • /
    • pp.114-121
    • /
    • 2003
  • The precise quantity of materials is not yet taken off by the CAD system although it has Influenced in design productivity and automatic estimate. And various estimate systems developed so far deal with the quantity take-off of building members separately, which caused to over-estimate the part of each member. Therefore, the purpose of this paper is to develop algorithms of more precise estimate than that of current estimate by solving boundary conditions of the connection parts of building members, such as column, girder, beam, wall and slab. The algorithms are proposed to take off the quantity of concrete and form work and they will be used for the estimate of building structure more precisely and automatically than ever.

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.

Benefit·Cost Analysis of Combine Method Using Hollow Precast Concrete Column (중공 PC기둥 복합공법의 편익-비용 분석)

  • Kim, Jae-Yeob;Park, Byeong-Hun;Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.429-436
    • /
    • 2016
  • Because of the shortage of construction workers due to The rising labor costs and an aging labor force, construction time has been extended. As a solution, The construction time of high-rise buildings can be reduced by adopting precast concrete construction methods. Most relevant studies have focused on the development and structural analysis of such methods and not on their construction management. Therefore, this study focused on the construction management of the hollow precast concrete column (HPC) method. The objective of this study was to evaluate the performance of HPC formulations through the analytic hierarchy process and benefit-cost analysis. After a gap analysis of the available literature and expert interviews, the evaluation criteria were selected. A questionnaire survey was administered to professionals with ample experience in precast concrete construction for the pair-wise evaluation of the benefit and costs of the HPC method. The results show that the benefits of the HPC method outweighed its costs. Therefore, the HPC method is a suitable substitute for the half-slab method.