공동주택의 성능기반설계 시 내진철근의 영향평가 (Performance Based Seismic Design of Apartment Houses by Applying Seismic Rebar)

  • 조민주;유성용;강지연;김형근
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.115-122
    • /
    • 2017
  • In this study, performance based seismic design was performed on the shear wall structural system and the beam-column system as a variable general rebar and seismic rebar, and comparing the capacity of the two models of each system. From nonlinear analyses, the capacity of the shear wall structural system applying seismic rebar has shown a stable behavior after the maximum strength, but there is little difference. Furthermore, both models showed similar capacity between story drift and story shear force and capacity of members. These results are attributed to the fact that the seismic rebar, which is highly ductile under the seismic load applied to the target structure, does not render sufficient capacity.

양방향 나사산 체결방식을 활용한 완전밀착형 커플러의 시공성 분석 (Experimental Study on Field Applicability of Tightened Coupler with Two-Way Threading)

  • 박우열;홍성욱;양진국;고석화;안성훈
    • 한국건축시공학회지
    • /
    • 제14권1호
    • /
    • pp.87-93
    • /
    • 2014
  • 본 연구에서는 기존의 일방향 나사산 커플러 이음을 개선한 양방향 나사산 체결방식을 활용한 완전밀착형 커플러를 제안하고 시공성을 분석하였다. 시공성을 분석하기 위해 실물 실험 모형을 설치하여 실험하였다. 수평철근은 매트기초의 수평철근을 대상으로 실험하였다. 수직철근의 경우 기존 선조립 커플러 이음 공법의 문제점을 분석하여 반조립 커플러 이음 공법을 제안한 후 적용하였다. 적용결과 수평철근의 경우 D25와 D29 모두 양방향 나사산 커플러 이음의 체결시간이 기존 커플러 이음보다 짧은 것으로 나타났다. 수직철근은 반조립 형태로 배근할 경우 기둥 주근 한 개를 약15초에 체결할 수 있는 것으로 나타났다. 기존 현장 조립 커플러 이음에 비해 쉽고 안전하게 작업할 수 있고, 철근을 완전하게 밀착시킬 수 있기 때문에 품질 및 비용, 공기 측면에서 충분히 활용가능할 것으로 판단된다.

섬유혼입공법을 적용한 고강도콘크리트 기둥의 재하 내화시험 (Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns with Loading)

  • 염광수;전현규;김흥열
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.473-480
    • /
    • 2009
  • 폴리프로필렌섬유와 강섬유를 혼입한 고강도콘크리트 기둥의 재하하중비에 따른 내화성능을 검증하기 위하 여 3기의 동일한 기둥시험체를 제작하여 각 시험체에 40%, 50%, 그리고 61%의 설계하중에 해당하는 고정압축하중을 재하한 후 ISO-834 표준내화곡선에 따라 180분간 내화시험을 실시하였다. 폭렬은 발생하지 않았으며, 표면부의 색은 분 홍색을 띤 회색으로 변했다. 시험체의 최대 연직방향 처짐은 1.5~2.2 mm로, 내화시험 중 화재로 인한 시험체의 강도손 실이 발생하지 않았으며, 설계하중의 61%이내에서 시험체의 내화성능은 영향을 받지 않았다. 깊이별 내부 콘크리트의 온도분포, 콘크리트 내부 수분 증발로 인한 온도상승이 변한 점 등 전반적으로 비재하 내화시험 결과와 매우 유사하였다. 180분 내화시험 후의 최종온도는 모서리철근이 491.4oC, 중앙철근이 329.0oC이며, 철근의 총 평균온도는 409.8oC이다. 전 반적인 온도분포의 경향은 비재하 내화시험과 매우 유사하였다. 모서리철근의 열에너지 유입량이 많기 때문에 중앙철 근과의 온도차(153.7oC)가 나타났으며, 가열 후 30~50분 사이에 온도상승추세가 변하였다. 이는 강섬유와 폴리프로필렌 섬유를 혼입한 콘크리트의 온도구배가 낮고, 철근으로의 수분이동과 내부 수분의 막힘현상, 그리고 수분의 기화열 때문이다.

BIM기반 초기 설계 단계 철근 물량 산출 프로세스 구축 (Establishment of Rebar Quantity Estimation in BIM-based Initial Design Phase)

  • 송치호;김치경;이시은;최현철
    • 한국전산구조공학회논문집
    • /
    • 제29권5호
    • /
    • pp.447-454
    • /
    • 2016
  • 최근에 각광받고 있는 3D BIM기반 철근 물량 산출 현황을 살펴보면 상용 BIM 도구들이 철근 모델링 기능을 제공하지만 그 기능을 이용해서 철근을 모델링하려고 하면 방대한 양의 모델링 시간이 소요가 되어 현재 실용적으로 사용할 수 있는 BIM 소프트웨어는 없다. 본 연구에서는 BIM 기반 설계 현업에서 실용적인 철근 물량 산출 프로세스를 정리 및 제시하고, 초기설계단계의 단면 정보가 없는 상태에서 기존의 2D방식에 비하여 보다 정확하게 기동, 보, 슬래브, 벽체의 철근 단면 정보를 자동으로 배근해주는 프로그램인 Rebar Automatic Arrangement Program(이하 RAAP)을 개발하였다. 본 연구 결과는 건설프로젝트의 초기 설계단계에서 설계 진행상 구조 부재 단면 설계가 완료되지 않은 상태의 골조 물량 산출 시 적은 노력으로 기존의 2D기반 방식보다 신뢰성을 향상시킨 물량을 산출할 수 있는 기술로 발전시키는데 의미가 있으며, 합리적인 초기 설계단계의 물량 산출 프로그램을 구축할 수 있는 기초 연구로서 활용될 수 있을 것으로 기대된다.

원전구조물의 외부 보기둥 접합부에서 철근 기계적 정착 (Headed Bar Anchorage of Exterior Beam Column Joints in Nuclear Power Plants)

  • 천성철;이성호;오보환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.42-45
    • /
    • 2006
  • This study investigated headed bar anchorage of exterior beam column joints in nuclear power plants. In nuclear power plant structures, anchorage of headed bar is recommended to satisfy ACI 349-01 App. B that are based on the Concrete Capacity Design (CCD) method. However, CCD method may lead to very conservative results for beam column joints where head is anchored within the diagonal strut and concrete is confined by transverse rebar. Compared with results of 5 joint specimens, the anchorage capacities calculated by ACI 349-01 are underestimated by 70-90%. Therefore, it is necessary to amend ACI 349-01 for the mechanical anchorage in beam column joints.

  • PDF

PC 다층 연성 골조시스템의 현장적용 사례 연구 (Application of PC Beam-Column Interior Joint with Splice Type Re-bar)

  • 김준호;전병갑;박순규;김광희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.9-13
    • /
    • 2006
  • The purpose of this study was to introduce the applied care of PC beam-column interior joint with splice type rebar. In this case, although the erection time of the introduced case was a little bit higher than that of general precast concrete method, this method was more effective than general precast concrete method in aspect of direct cost and the number of column joint. Therefore, this method could be adopted in the construction of the commercial and residential building in the future.

  • PDF

비닐하우스 기초 토양의 다짐률 변화에 따른 전단강도 특성 (Experimental Evaluation of Shear Strength of Surface Soil Beneath Greenhouse Varying Compaction Rate)

  • 임성윤;허기석;곽동엽
    • 한국농공학회논문집
    • /
    • 제63권6호
    • /
    • pp.17-26
    • /
    • 2021
  • Greenhouses have been damaged due to the uplift pressure from strong wind, for which rebar piles are often installed near the greenhouse to resist the pressure. For the effective design of rebar piles, it is necessary to access the shear strength of soil on which the greenhouse is constructed. This study experimentally evaluates the shear strength of the soil beneath the greenhouse. Four soil samples were collected from four agricultural sites, and prepared for testing with 75, 80, 85, and 90% compaction rates. One-dimensional unconfined compression test (UC), consolidated-undrained triaxial test (CU), and resonant column test (RC) were performed for the evaluation of shear strength and shear modulus. Generally, the higher shear strength and modulus were observed with the higher compaction rates. In particular, the UC shear strength increases with the increase of #200 sieve passing rate. Resulting from the CU test, the sample with the most of coarse soil had the highest friction angle, but the variation is small among samples. Resulting from the CU and RC tests, the ratio of maximum shear modulus with the major principle stress at failure was the higher at the finer soil. The ratio was two to three times greater than the ratio from the standard sand. This indicates that the shear strength is lower for the fine soil than the coarse soil at the same shear modulus. The results of this study will be a useful resource for the estimation of the pull-out strength of the rebar pile against the uplift pressure.

Strain penetration of high-strength steel bars anchored in reinforced concrete beam-column connections

  • Li, Ling;Zheng, Wenzhong;Wang, Ying
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.367-382
    • /
    • 2019
  • This paper presents experimental and analytical investigations on additional fixed-end rotations resulting from the strain penetration of high-strength reinforcement in reinforced concrete (RC) beam-column connections under monotonic loading. The experimental part included the test of 18 interior beam-column connections with straight long steel bars and 24 exterior beam-column connections with hooked and headed steel bars. Rebar strains along the anchorage length were recorded at the yielding and ultimate states. Furthermore, a numerical program was developed to study the effect of strain penetration in beam-column connections. The numerical results showed good agreement with the test results. Finally, 87 simulated specimens were designed with various parameters based on the test specimens. The effect of concrete compressive strength ($f_c$), yield strength ($f_y$), diameter ($d_b$), and anchorage length ($l_{ah}$) of the reinforcement in the beam-column connection was examined through a parametric study. The results indicated that additional fixed-end rotations increased with a decrease in $f_c$ and an increase in $f_y$, $d_b$ and $l_{ah}$. Moreover, the growth rate of additional fixed-end rotations at the yielding state was faster than that at the ultimate state when high-strength steel bars were used.

On the use of numerical models for validation of high frequency based damage detection methodologies

  • Aguirre, Diego A.;Montejo, Luis A.
    • Structural Monitoring and Maintenance
    • /
    • 제2권4호
    • /
    • pp.383-397
    • /
    • 2015
  • This article identifies and addresses current limitations on the use of numerical models for validation and/or calibration of damage detection methodologies that are based on the analysis of the high frequency response of the structure to identify the occurrence of abrupt anomalies. Distributed-plasticity non-linear fiber-based models in combination with experimental data from a full-scale reinforced concrete column test are used to point out current modeling techniques limitations. It was found that the numerical model was capable of reproducing the global and local response of the structure at a wide range of inelastic demands, including the occurrences of rebar ruptures. However, when abrupt sudden damage occurs, like rebar fracture, a high frequency pulse is detected in the accelerations recorded in the structure that the numerical model is incapable of reproducing. Since the occurrence of such pulse is fundamental on the detection of damage, it is proposed to add this effect to the simulated response before it is used for validation purposes.