• Title/Summary/Keyword: column effective length

Search Result 107, Processing Time 0.037 seconds

Evaluation of shear lag parameters for beam-to-column connections in steel piers

  • Hwang, Won-Sup;Kim, Young-Pil;Park, Yong-Myung
    • Structural Engineering and Mechanics
    • /
    • v.17 no.5
    • /
    • pp.691-706
    • /
    • 2004
  • The paper presents shear lag parameters for beam-to-column connections in steel box piers. Previous researches have analyzed beam-to-column connections in steel piers using a shear lag parameter ${\eta}_o$ obtained from a simple beam model, which is not based on a reasonable design assumption. Instead, the current paper proposes a cantilever beam model and has proved the effectiveness through theoretical and experimental studies. The paper examines the inaccuracy of the previous researches by estimating the effective width, the width-span length ratio L/b, and the sectional area ratio S of a cantilever beam. Two different shear lag parameters are defined using the cantilever model and the results are compared each other. The first type of shear lag parameter ${\eta}_c$ of a cantilever beam is derived using additional moments from various stress distribution functions while the other shear lag parameter ${\eta}_{eff}$ of a cantilever beam is defined based on the concept of the effective width. An evaluation method for shear lag stresses has been investigated by comparing analytical stresses with test results. Through the study, it could be observed that the shear lag parameter ${\eta}_{eff}$ agrees with ${\eta}_c$ obtained from the $2^{nd}$ order stress distribution function. Also, it could be observed that the shear lag parameter ${\eta}_c$ using the $4^{th}$ order stress distribution function almost converges to the upper bound of test results.

Experimental Study on Flexural Behavior of PC Beam Column Joint with Spliced Strand (강선 이음길이에 따른 PC 보-기둥 접합부의 휨 거동에 관한 실험적 연구)

  • 하상수;김승훈;문정호;이리형;이강철;김익배
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.207-210
    • /
    • 2003
  • As reviewing of current trend on PC connection details, owing to effective stress transfer in the connection, it grow to increase that use of mechanical splices, reinforcements or welded splices, and prestressing. However such devices as reinforcement, mechanical splices entail not only more cost resulted from materials but also extra construction process so as to cause PC used method to lower competition against conventional method. Therefore more enhanced connection details which help working process simplified and construction cost reduced. In this research, as replace 9.3mm 7strand for reinforcement, it is attempt to devise connection detail which makes workability improve and confirm effective stress transfer in the region of connection. The experimental research is proceeded by partial tension test of specimen. The splice lengths of 7strand is decided to be variations. The flexural capability is verified to depend on spice length. An an appropriate splice length could be also determined as a precedent research on improving PC connection detail.

  • PDF

The Effect of Anchorage of Reinforcement in Slab-Column Connection (슬래브-기둥 접합부에서 전단보강체에 정창성능에 따른 영향)

  • Choi, Huyn-Ki;Kim, Jun-Seo;Lee, Moon-Sung;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.185-188
    • /
    • 2008
  • Flat plate system has structural weakness such as punching shear. Punching shear resistance can be increase by using a lager column section and effective depth, higer concrete compressive strength, and more flexural reinforcement ratio. But using a shear reinforcement is most economical, enable, workable solution in flat plate. The slab with thickness smaller than 250mm can not perform effectively due to insufficient development length of shear reinforcement in the slab. In case of proposed reinforcements, since the shear reinforcements were installed between the top bar and the bottom bar, shear elements generated slip failure before they reached yield. strength. effect of anchorage strength were effective anchorage length, concrete strength, diameter of shear element and anchorage detail. considering effect of slab thickness and concrete strength, formula of K factor propose in thin flat plate slab. by considering effect of anchorage length and concrete strength, strength of shear reinforcement will be computed correctly in thin flat plate slab.

  • PDF

Analysis of CFT Column-RC Flat Plate Interior Connections under Lateral Load (횡하중을 받는 CFT기둥-RC무량판 접합부의 해석연구)

  • Song, Jin-Kyu;Song, Ho-Bum;Oh, Sang-Won;Kim, Byung-Jo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.867-870
    • /
    • 2008
  • Flat plate system has many advantages, story height reduction, a term of works shortening and changeableness of space, etc. However structures become a tendency of higher stories and when we use RC column, the size of column grow larger. For this reason the use of CFT column is increasing more and more. Accordingly, this study carried out the nonlinear finite element analysis. As a result of analysis moment strength of the connection increased but ductility decreased as the top reinforcement ratio in th effective width increased. And moment strength and ductility of the connection decreased as gravity load ratio decreased. In the case that shearhead length is not more than 0.27m, the effectiveness of shearhead length on the moment strength and ductility of the connection were small relatively to other variables. Initial stiffness and moment strength of connection increased as slab thickness increased

  • PDF

Numerical Upwelling Experiment for Optimum Arrangement of Artificial Seamount (용승을 고려한 인공해중산 최적배치 수치실험)

  • Kim, Seong-Hyeon;Kim, Dong-Sun
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.997-1009
    • /
    • 2011
  • In order to estimate volume transport by upwelling for single artificial seamount, same shape and size of artificial seamount already deployed was applied to numerical experiment. The result showed that strong upwelling appeared at front while took place downwelling at rear. The strongest upwelling existed at the top of the artificial seamount. Volume transport by upwelling was computed as 785 m3/s. Column arrangement was applied to two artificial seamount in three cases; case 1) no clearance, case 2) sixty-five meters of clearance as half of artificial seamount's length, and case 3) hundred-thirty meters of clearance as an artificial seamount's length. All cases of column arrangements showed more upwelling volume transport than that of single seamount. Particularly, the case of no clearance calculated as 106% and appeared the most upwelling effect comparing to two other cases. Row arrangement was also applied to two artificial seamount in three cases; case 4) no clearance, case 5) forty meters of clearance as an artificial seamount's width, and case 6) eighty meters of clearance as twice of artificial seamount's width. Upwelling volume transport in case 4 increased 48% than the case of single seamount. Other two cases of 5 and 6 were estimated as 97% increased and more effective than case 4. According to the case experiments, column arrangements show more upwelling volume transport than that of row arrangements. In cases of column arrangements, with decreasing clearance between two seamount, the effect increases while showing maximum value at clearance zero. In cases of row arrangements, on the contrary, with decreasing clearance between two seamount, the effect decreases while showing minimum value at clearance zero. Since simple barotropic condition was considered for this study, further study is necessary by considering baroclinic condition to get close to reality. In conclusion, in deploying artificial seamount, optimal arrangement should be well designed to enhance primary and secondary productivity and to increase the diversity of species as well as reducing time and space.

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Lee, Sang-Hyun;Chung, Lan;Lee, Joung-Woo;Cho, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Chung, Lan;Lee, Joung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

Mechanical Behavior of Slender Concrete-Filled Fiber Reinforced Polymer Columns

  • Choi Sokhwan;Lee Myung;Lee Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.565-572
    • /
    • 2004
  • The mechanical behavior of concrete-filled glass fiber reinforced polymer columns is affected by various factors including concrete strength, stiffness of tube, end confinement effect, and slenderness ratio of members. In this research the behavior of slender columns was examined both experimentally and analytically. Experimental works include 1) compression test with 30cm long glass fiber composite columns under different end confinement conditions, 2) uni-axial compression test for 7 slender columns, which have various slenderness ratios. Short-length stocky columns gave high strength and ductility revealing high confinement action of FRP tubes. The strength increment and strain change were examined under different end confinement conditions. With slender columns, failure strengths, confinement effects, and stress-strains relations were examined. Through analytical work, effective length was computed and it was compared with the amount of reduction in column strength, which is required to predict design strength with slender specimens. This study shows the feasibility of slender concrete-filled glass fiber reinforced polymer composite columns.

Stiffness Prediction of Flatplate System According to Column Section Shape (기둥단면 형상에 따른 무량판 구조시스템 강성예측)

  • Lee, Do-Bum;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.194-202
    • /
    • 2006
  • In the present study, stiffness prediction methodologies for flat-plate structures were evaluated in comparison with the experimental results on the full-scale slab-column connections of flat-plate structures. The methodologies are as follows: the methodology proposed by Jacob S. Grossman and the methodology proposed by Choi & Song. The former does not predict the stiffness change of the slab-column connection due to the change in the column section shape and the latter overestimates the stiffness when edge length of the column section in the loading direction is long. In the present study, the equation to calculate the effective width of slabs was modified to reflect the effect of the change in the column section shape.

Cathodic Protection Characteristics and Effective Length of Protection Current of Concrete Pile using Zn-mesh Sacrificial Anode (아연 메쉬 희생양극을 이용한 콘크리트 파일의 음극방식 특성 및 방식전류 유효거리)

  • Kim, Ki-Joon;Jeong, Jin-A;Lee, Woo-Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.773-776
    • /
    • 2008
  • The corrosion of steel in concrete is significant in marine environment. Marine bridges are readily deteriorated due to the exposure to marine environment. Salt damage is one of the most detrimental causes to concrete bridges and port structures. Especially, the splash and tidal zones around water line are comparatively important in terms of safety and life-time point of view. During the last several decades, cathodic protection (cp) has been commonly accepted as an effective technique for corrosion control in concrete structures. Zn-mesh sacrificial anode has been recently developed and started to apply to the bridge column cp in marine condition. The detailed parameters regarding Zn-mesh cp technique, however, have not well understood. This study is to investigate how much Zn-mesh cp influences along the concrete column at elevated temperature. About 100cm column specimens with eight of 10cm segment rebars have been used to measure the variation of cp potential with the distance from Zn-mesh anode at both 10$^{\circ}$C and 40$^{\circ}$C in natural seawater. The cp potential change and current diminishment along the column specimens have been discussed for the optimum design of cp by Zn-mesh sacrificial anode

  • PDF