• Title/Summary/Keyword: color calculation

Search Result 151, Processing Time 0.025 seconds

Correlation between Skin Translucency and Scattering Reflection using Miniaturized New Optical Device (피부 투명감 측정 기기의 소형화 및 피부의 확산 반사광과 투명감 사이의 연구)

  • Lee, Myeong-Ryeol;Jeong, Choon-Bok;Junng, Yu-Chul;Kim, Han-Kon;Nam, Gae-Won
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • Skin darkness is the source of trouble to many women. Skin darkness is the state that while skin redness and brightness are reduced, skin yellowness is increased. Skin translucency which is measured by skin color, especially brightness is an another expression of skin darkness. Skin brightness is usually expressed by L value of $L^{*} \;a^{*}\; b^{*}$ (CIELAB color space system). However, it is hard to find the relationship between L value and perceptive efficacy such as translucency because the L value is just a factor of evaluation of skin darkness. The skin with high translucency has high scattering reflective light value than low value. In this study, we measured the skin translucency of 20 ~ 30 ages men and women face by both our designed previous device which use polarized light to detect surface and scatter reflective light independently and $Lumiscan^{TM}$ which is improved designed to confirm our new device working ability by calculation of relationship between trnaslucency and scattering reflective light value. The result of this study indicate that there is a high correlation (R = 0.732, p < 0.01) between translucency and scattering reflective light value, and suggest that $Lumiscan^{TM}$ is portable and easy measuring device more that previous device.

Estimation of Simulated Radiances of the OSMI over the Oceans (대양에서의 OSMI 모의 복사량 산출)

  • 임효숙;김용승;이동한
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.227-238
    • /
    • 1999
  • In advance of launch, simulated radiances of the Ocean Scanning Multispectral Imager (OSMI) will be very useful to guess the real imagery of OSMI and to prepare for data processing of OSMI. The data processing system for OSMI which is one of sensors aboard Korea Multi-Purpose Satellite (KOMPSAT) scheduled for launch in 1999 is developed based on the SeaWiFS Data Analysis System (SeaDAS). Simulation of radiances requires information on the spectral band, orbital and scanning characteristics of the OSMI and KOMPSAT spacecraft. This paper also describes a method to create simulated radiances of the OSMI over the oceans. Our method for constructing a simulated OSMI imagery is to propagate a KOMPSAT orbit over a field of Coastal Zone Color Scanner (CZCS) pigment concentrations and to use the values and atmospheric components for calculation of total radiances. A modified Brouwer-Lyddane model with drag was used for the realistic orbit prediction, the CZCS pigment concentrations were used to compute water-leaving radiances, and a variety of radiative transfer models were used to calculate atmospheric contributions to total radiances detected by OSMI. Imagery of the simulated OSMI radiances for 412, 443, 490, 555, 765, 865nm was obtained. As expected, water-leaving radiances were only a small fraction (below 10%) of total radiances and sun glint contaminations were observed near the solar declination. Therefore, atmospheric correction is critical in the calculation of pigment concentration from total radiances. Because the imagery near the sun's glitter pattern is virtually useless and must be discarded, more advanced data collection planning will be required to succeed in the mission of OSMI which is consistent monitoring of global oceans during three year mission lifetime.

2D Interpolation of 3D Points using Video-based Point Cloud Compression (비디오 기반 포인트 클라우드 압축을 사용한 3차원 포인트의 2차원 보간 방안)

  • Hwang, Yonghae;Kim, Junsik;Kim, Kyuheon
    • Journal of Broadcast Engineering
    • /
    • v.26 no.6
    • /
    • pp.692-703
    • /
    • 2021
  • Recently, with the development of computer graphics technology, research on technology for expressing real objects as more realistic virtual graphics is being actively conducted. Point cloud is a technology that uses numerous points, including 2D spatial coordinates and color information, to represent 3D objects, and they require huge data storage and high-performance computing devices to provide various services. Video-based Point Cloud Compression (V-PCC) technology is currently being studied by the international standard organization MPEG, which is a projection based method that projects point cloud into 2D plane, and then compresses them using 2D video codecs. V-PCC technology compresses point cloud objects using 2D images such as Occupancy map, Geometry image, Attribute image, and other auxiliary information that includes the relationship between 2D plane and 3D space. When increasing the density of point cloud or expanding an object, 3D calculation is generally used, but there are limitations in that the calculation method is complicated, requires a lot of time, and it is difficult to determine the correct location of a new point. This paper proposes a method to generate additional points at more accurate locations with less computation by applying 2D interpolation to the image on which the point cloud is projected, in the V-PCC technology.

A Study on Touch-screen Development Using Visible-ray (가시광선을 이용한 터치스크린 구현에 대한 연구)

  • Park, Jun-Woo;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.50-61
    • /
    • 2011
  • The Infrared touch method is generally used for a mid and large-size touch screen. But this method has several problems, such as difficulty with installation of a touch-object recognition device, limited application and coordinate error in multi-point touch system. Since we can take advantages of both color and local information when we use general cameras for a touch screen, a touch screen using general camera is more efficient than infrared one. It also has an advantage of easy installation of a touch-object device. However, it did not much appeal in a market because of several problems, such as color sensitivity, illumination and reflected light. In this paper, we study a method for a touch screen using a general camera and image processing method to recognize touch objects and coordinate calculation method to single and multi-point touch screen. It has the same recognition performance as an infrared touch screen for single-point method. And it does not have ghost point problem by using distance information of touch object and camera in multi-point touch system. But recognition performances of multi-point touch screen are less than single-point. If we improve execution time, this method can replace an infrared method for a single point touch screen, according to result of experience.

Development of the Reference Korean Female Voxel Phantom (한국인 기준여성 체적소형 모의체 개발)

  • Ham, Bo-Kyoung;Cho, Kun-Woo;Yeom, Yoen-Soo;Jeong, Jong-Hwi;Kim, Chan-Hyeong;Han, Min-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was $1.976{\times}1.976{\times}2.0619\;mm^3$ and the voxel array size is $261{\times}109{\times}825$ in the x, y and z directions. Then, the voxel resolution was changed to $2.0351{\times}2.0351{\times}2.0747\;mm^3$ for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.

Lightness Compensation for Anaglyph Images to Reduce Retinal Rivalry (Anaglyph 영상의 망막경합 최소화를 위한 밝기 보상)

  • Jang, Woo-Heon;Lee, Tae-Hyoung;Kim, Dae-Chul;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.88-96
    • /
    • 2012
  • According to development of technology for media, observers try to watch the realities from images, as follows, 3D imaging has been extremely developed. 3D image gives depth in the image, observers feel in nature. Different image perception from left and right eyes make the 3D image. Anaglyph which is one of the ways to make an image of three dimensions is for obtaining an image of three dimensions by using color filter glasses. Anaglyph has a little amount of calculation and is easy to make, and it has a good point that anaglyph can be used in more wide field because it can create an image of three dimensions to the output of print like printed matter. However, the phenomenon of retinal rivalry can cause a feeling of fatigue because a difference of brightness of the left image and the right image happen. The way to reduce this problem is made by cutting down a difference of brightness. In the result, retinal rivalry can be reduced. We reduced a difference of the brightness of the left and the right image by utilizing the brightness and average of the original image to reduce retinal rivalry and we made better colors of anaglyph by using the way that we keep the hue caused by a change of brightness and supplement saturation about color distortion which is created at that time.

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

A New Stereo Matching Method based on Reliability Space (신뢰도 공간에 기반한 스테레오 정합 기법)

  • Lee, Seung-Tae;Han, Young-Joon;Hahn, Hern-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.82-90
    • /
    • 2010
  • In this paper, A new stereo matching method based on reliability space is proposed to acquire 3D information from 2D image. In conventional stereo matching methods, speed is sacrificed to achieve high accuracy. To increase the matching speed while maintaining a high accuracy, this paper proposes this stereo matching method. It first makes the disparity space image for comparing all of the pixels on the stereo images. Then it produce reliability space through analyzing this value. and, By comparing the reliability space according to disparity, it makes disparity map. Moreover, the parts that make regional boundary errors are corrected by classifying the boundary of each region with the reference to color edge. The performance of the proposed stereo matching method is verified by various experiments. As a result, calculation cost is reduced by 30.6%, while the image quality of proposed method has similar performance with the existing method.

Screening of SrO-B2O3-P2O5 Ternary System by Combinatorial Chemistry and QSAR (조합화학과 QSAR를 이용한 SrO-B2O3-P2O5 3원계 청색형광체 개발)

  • Yoo, Jeong-Gon;Back, Jong-Ho;Cho, Sang-Ho;Sohn, Kee-Sun
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.6 s.277
    • /
    • pp.391-398
    • /
    • 2005
  • It is known that $BaMgAl_{10}O_{17}:Eu^{2+}(BAM)$ phosphors currently used have a serious thermal degradation problem. We screened $SrO-B_2O_3-P_2O_5$ system by a solution combinatorial chemistry technique in an attempt to search for a thermally stable blue phosphor for PDPs. A Quantitative Structure Activity Relationship (QSAR) was also obtained using an artificial neural network trained by the result fiom the combinatorial screening. As a result, we proposed a promising composition range in the $SrO-B_2O_3-P_2O_5$ ternary library. These compositions crystallized into a single major phase, $Sr_6BP_5O_{20}:Eu^{2+}$. The structure of $Sr_6BP_5O_{20}:Eu^{2+}$ was clearly determined by ab initio calculation. The luminescent efficiency of $Sr_6BP_5O_{20}:Eu^{2+}$ was 2.8 times of BAM at Vacuum Ultra Violet (VUV) excitation. The thermal stability was also good but the CIE color chromaticity was slightly poor.