• Title/Summary/Keyword: collecting cell

Search Result 109, Processing Time 0.026 seconds

Ion Transports in Mouse Collecting Duct Cells (M-1)

  • Park, Mi-Young;Song, Jin-Mi;Jang, Phil-Geum;Lee, Ryang-Hwa;Jung, Jin-Sup
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1999.06a
    • /
    • pp.50-50
    • /
    • 1999
  • The mammalian cortical collecting duct (CCD) plays a major role in regulating renal NaCl absorption, which is important in controlling total body Na and Cl homeostasis. The M-1 cell line, derived from the mouse cortical collecting duct, is being used as a mammalian model of the CCD to study electrolytes transport.(omitted)

  • PDF

Evaluation of Micro-Tubular SOFC: Cell Performance with respect to Current Collecting Method (마이크로 원통형 SOFC 특성평가: 집전방식에 따른 단위전지의 전기화학적 특성)

  • Kim, Hwan;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • This paper presents the characterization of micro-tubular SOFCs using three different anode current collecting methods of inlet current collection (IC), both current collection (BC) and total current collection (TC). The maximum power densities of SOFCs at $750^{\circ}C$ using IC, BC and TC were 56 mW/$cm^2$ (0.43 V, 0.13 A/$cm^2$), 236 mW/$cm^2$ (0.43 V, 0.55 A/$cm^2$) and 261 mW/$cm^2$ (0.43 V, 0.61 A/$cm^2$) respectively. It was confirmed by impedance spectroscopy that both the polarization resistance and the ohmic resistance were dramatically increased at SOFC with IC.

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 자가 수혈체계[Cell Saver]의 이용 효과)

  • 안욱수
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1312-1317
    • /
    • 1992
  • Autologous blood transfusion is a common method of reducing the need for homologous blood transfusion during cardiac operations. Between June 1991 and May 1992, 12 cases [Group I] were experienced autologous blood transfusion using Cell Saver undergoing double valve replacement or redo-valve replacement. Control group [N=12, Group II] was selected to above similar operation during same period. The Cell Saver system [Haemonetics Corp.] was employed for autologous blood transfusion. The blood shed in the operative field before and after cardiopulmonary bypass and remained cardiotomy reservior was aspirated by means of a locally heparinized collecting system. After centrifused salvaged blood, the resulting red cell concentrate reinfused subsequently. The patient receiving autologous blood transfusion required significantly less homologous blood transfusion than their control group. [Group I; 3519 $\pm$ 869, Group II; 4622 $\pm$ 856, Respectively; P=0.005] There were no clinical infections in the autotransfusion group. And there was no apparent intergroup difference of the clinical findings, hematologio datas and coagulation parameters. We conclude the autotransfusion using Cell Saver is effective for reducing of the hom-ologlous blood transfusion in cardiac surgery.

  • PDF

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 Cell Saver 를 이용한 자가수혈의 효과)

  • 정경영
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.260-267
    • /
    • 1990
  • During a eight month period[from December, 1988 to July, 1989], a series of 35 adults undergoing redo-valve replacement or coronary artery bypass grafting was selected to an autotransfusion group[n=10] or a control group[n=25]. The Cell Saver System[Haemonetics Corp., Graintree, Mass] was employed for autotransfusion. With this system, all blood shed in the operative field before and after cardiopulmonary bypass and remained in cardiotomy reservoir after cardiopulmonary bypass was aspirated by means of a locally heparinized collecting system. After the salvaged blood was centrifuged, the resulting red cell concentrate subsequently reinfused. The patients receiving autologous blood required significantly less banked homologous blood than their controls[3213k1020 ml and 506051931 ml, respectively: p=0.001] There were no clinical infections in the autotransfusion group, although 40% of the cultures of processed blood were positive. And there was no apparent intergroup difference of the clinical and the hematologic and hemostatic laboratory findings. We conclude that autotransfusion using cell saver is effective for saving the homologous blood transfusion in cardiac surgery.

  • PDF

Indoor Wireless Optical Communication Using a Lighting LED and a Solar Cell (조명용 LED와 솔라 셀을 이용한 실내 무선광 통신)

  • Lee, Seong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.285-291
    • /
    • 2010
  • In this paper, we demonstrate that indoor wireless optical communication is possible with an LED and a solar cell. A lighting LED is used for lighting and signal transmission. A solar cell is used for collecting light energy and signal detection. This scheme is very useful because transmission is possible without any additional communication systems. In experiments, wireless optical communication was carried out at a data rate of 9.6 kbps using a lighting LED and a solar cell.

Development of Tubular Solid Oxide Fuel Cells with Advanced Anode Current Collection (연료극 집전체 최적화를 적용한 원통형 고체산화물 연료전지 단전지 성능 향상)

  • Kim, Wanje;Lee, Seungbok;Song, Rakhyun;Park, Seokjoo;Lim, Takhyoung;Lee, Jongwon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.480-486
    • /
    • 2013
  • In this study, tubular SOFC unit cell with advanced anode current collector was fabricated to improve the cell performance. First, we prepared two types of single cells having the same manufacture processes such as the same electrolyte, electrode coating condition and sintering processes. And then to compare the developed single cell performance with conventional cells, we changed the anode current collecting methods. From the impedance analysis and I-V curve analysis, the cell performance of advanced cell is much higher than that of conventional cell.

Development of An Accelerated Durability Test Mode for Fuel Cell (연료전지 가속내구모드 개발)

  • LEE, YONGHEE;OH, DONGJO;JEON, UISIK;LEE, JONGHYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.5
    • /
    • pp.493-498
    • /
    • 2015
  • The fuel cell vehicle is a type of hydrogen vehicle which uses a fuel cell to produce electricity, powering its on-board electric motor. The fuel cell vehicle driving principle is completely different from the internal combustion engine vehicle. In order to ensure the durable quality of the fuel cell vehicle, durability test mode considering the characteristics of the fuel cell must be developed. In this study, we derived the durability test mode profile through collecting and analyzing fuel cell vehicle driving data. Then, the accelerated durability test mode is developed by adding degradation conditions and is experimentally validated to have an acceleration factor of 5~6.

The Effects of Alpha Particles on the Sense Amplifier in Memory Devices (알파 입자가 기억소자의 SENSE AMP에 미치는 영향)

  • 이성규;한민구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.675-683
    • /
    • 1991
  • When alpha particles are incident into the substrate, we have calculated the advanced current caused by collecting charges as a function of time, the energy of alpha particle, and the carrier concentration of the substrate. Employing SPICE, we have compared two circuits of which one has dummy cell and another has dummy line instead of dummy cell, and both are connected to the bit line node including sense amplifier and cell within the memory device. From the numerical analysis, (it may be conjectured that)the smaller energy of alpha particle and the lower concentration of the substrate, the more possibility of misoperation due to alpha particles. It may be also found that the effects of alpha particle are substantially reduced in the circuit without dummy cell.

  • PDF

An Experimental Study on the Bee Venom Collector Using the Photovoltaic System (전원장치로 태양광을 이용하는 봉독 채집기에 관한 실험적 연구)

  • Cho, Nam-Cheol;Lee, Chae-Moon;Kim, Choul-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.122-127
    • /
    • 2011
  • A bee venom is very useful and expensive medical resource. A bee venom collector has some difficulties and inconveniences because of its complex component. This is used normal battery as an electric power. However, using the solar cell of the bee venom collector reduces economic burden and guarantees high efficiency. We have performed comparative experiment between the bee venom collector to use battery and the one to use solar cell(polycrystalline silicon) by collecting the bee venom simultaneously. At the same electricity, the electric frequency(AC),312 Hz is more superior than 450Hz. This paper verified through the experiments that the bee venom collector to adopt solar cell is more effective than normal collector.

Analysis of Flow Field around Multiple Fluid Spheres in the Low Knudsen Number Region (저 누드센 영역에서 다중 유체구 주위의 유동장 해석)

  • 정창훈;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.733-743
    • /
    • 2003
  • The flow field in multiple fluid sphere systems was studied analytically. The expanded zero vorticity cell model based on Kuwabara's theory (1959) was applied and the effects of gas slippage at the collecting surface were considered. Also, the solid sphere system was extended to fluid sphere including the effects of the induced internal circulation inside the liquid droplet spheres or gas bubble systems. As a result, the obtained analytic solution was converged to the existing solutions for flow field around solid and bubble sphere systems with proper boundary conditions. Based on the resolved flow field, the terminal velocity around the collecting fluid spheres was obtained. Subsequently, this study evaluated the most general solution for flow field around the multiple fluid sphere systems. The obtained flow field in multiple fluid sphere could be used as a fundamental consideration of wet scrubber design and devices for removing particles by fluid-fluid interactions.