• Title/Summary/Keyword: cold attenuation

Search Result 16, Processing Time 0.027 seconds

Photon Defects due to Residual Barium in the Colon Simulating Cold Bone Metastasis in Two Patients with Extraskeletal Cancer (골격외 종양 환자에서 냉소 골전이와 유사하게 보인 잔류 바리움에 의한 광자 결손)

  • Lim, Seok-Tae;Kim, Min-Woo;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.5
    • /
    • pp.314-316
    • /
    • 2002
  • One of common causes of cold defects on bone scintigraphy is an attenuation artifact. Cold defects can be produced by belt buckles, buttons, earring, necklaces, or other metal objects. Cold lesions in the abdomen are also produced by retained barium in the gastrointestinal tract after recent barium studies. We observed artifacts due to retained barium in the colon on bone scintigraphy, which simulated cold bone metastases in two patients with extraskeletal cancer.

Studies on the Cold Attenuation and Protective Effects of a Thermostable Newscastle Disease Virus Isolated from Korean Pheasants (한국산 꿩으로부터 분리한 열안정성 뉴캣슬병 바이러스의 저온순화와 방어효과)

  • K. H. Kwak;S. C. Han;T. J. Kim;K. S. Chang;M. H. Jun;H. J. Song
    • Korean Journal of Poultry Science
    • /
    • v.28 no.2
    • /
    • pp.83-89
    • /
    • 2001
  • Newcastle disease virus, CBP-1 strain isolated from Korean pheasants was passaged for 173 times by 9-day-old specific pathogenic free (SPF) embryonated eggs at $37^{\circ}C$ (parent strain) and subsequently passaged for 15 (cold attenuation (CA) -15) and 30(cold attenuation (CA) -30) times by 10-day-old of commercial broiler chicks embryonated eggs at $29^{\circ}C$, respectively, The Physical and chemical properties (sensitivity to lipid solvents, low pH and thermostability), pathogenicity (mean death time, intracerebral pathogenic index and intravenous patho-genic index), safety, booster or protective effect and characterization of temperature sensitivity were measured in cold attenuated CA-15 or 30 strain and compared to those of parent CBP-1 strain. NDV, CBP-1 CA-30 strain acquired cold attenuation and decreased infectivity at $41^{\circ}C$ compared to those of parent strain grown at $37^{\circ}C$. It lost hemagglutination activity (HA) and cell infectivity at $56^{\circ}C$ for 30, 60, and 120 Min. CA-30 strain treated with ethyl ether also lost its HA and cell infectivity. Both CA-30 and parent strains exhibited a little resistant to HA at pH 3.0 glycine HCI buffer. Intracerebral pathogenic index (ICPI) and intravenous pathogenic index (IVPI) of parent strain were 1.12 and 1.45, but decreased to 0.75 and 0.00 in CA-30 strain, respectively. The safety was evaluated by mortality in chicks inoculated with 10$^{4.0}$ EID$_{50}$ /0.1 ml. The mortalities of parent, CA-30 and commercial Bl strains were 17.5, 12.0 and 0.0%, respectively. The safety of CA-30 strain was higher than that of parent strain. The booster effects of CA-30 strain and parent strain performed in 4-week-old chicks after being vaccinated with primary commercial Bl strain.

  • PDF

Web Lateral Control of Cold Rolling Mill Systems Using a Robust PID Control (강인 PID 제어를 이용한 냉간압연 시스템의 웹 횡방향 제어)

  • Park, Chintac;Kim, In-Soo;Lee, Young-Jin;Kim, Jong-Shik;Lee, Man-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.373-384
    • /
    • 2002
  • This paper presents a robust PID controller design technique using the concept of model matching method in the frequency domain. To design the robust PID controller satisfying disturbance attenuation and robust tracking property for a reference input, first an H$\infty$ controller satisfying given performance is designed using the H$\infty$ control method. And then, the parameters(proportional, integral, and derivative gains) of the robust PID controller are determined using the model matching at frequency domain. The proposed technique is applied to a position controller design of the web. The simulation results show that the proposed robust PID controller satisfies disturbance attenuation and tracking property.

Design of an LMI- Based H^{\infty} Servo Controller for Tandem Cold Mill (LMI 에 기초한 연속 냉간압연기의 H^{\infty} 서보 제어기 설계)

  • Kim, In-Soo;Hwang, I-Cheol;Lee, Man-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.1
    • /
    • pp.25-34
    • /
    • 2000
  • In this paper, we design a H^\infty servo controller for gauge control of tandem cold mill. To improve the performance of the AGC(Aotomatic Gauge Control) system based on the Taylor linearized model of tandem cold mill, the H^\infty servo controller is designed to satisfy robust stability, disturbance attenuation and robust tracking properties. The H^\infty servo controller problem is modified as an usual H^\infty control problem, and the solvability condition of the H^\infty servo problem depends on the solvability of the modified H^\infty control problem. Since this modified problem does not satisfied standard assumptions for the H^\infty control problem, it is solved by an LMI(Linear Matrix Inequality) technique. Consequently, the comparison between the H^\infty servo controller and the existing PID/FF(FeedForward) controller shows the usefulness of this study.

  • PDF

Thickness Control of Cold-Rolling Mills with Roll Eccentricity (롤편심을 포함한 냉간 압연시스템의 두께제어)

  • 김승수;김종식;황이철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.248-254
    • /
    • 1996
  • A disturbance rejection controller using eccentricity filtering and LQ control techniques is proposed to alleviate significantly the effect of roll eccentricity in multivariable cold-rolling processes. Fundamental problems such as process time delay inherent in exit thickness measurement and non-stationary characteristics of roll eccentricity signals can be overcome by the proposed control method. The filtered instantaneous estimate of roll eccentricity may be exploited to improve instantaneous estimate of the exit thickness variation based on roll force and roll gap mearsurements, and a feedforward compensator is augmented as a reference for a gaugemeter thickness estimator. And, LQ feedback controller is combined with eccentricity filter for the attenuation of the exit thickness variation due to the entry thickness variation. The simulation results show that eccentricity components have been significantly eliminated and simultaneously other distrubances also have been attenuated.

  • PDF

Multivariable Control of Cold-Rolling Mills with Roll Eccentricity (롤편심을 포함한 냉간압연 시스템의 다변수 제어)

  • Kim, Jong-Sik;Kim, Seung-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.502-510
    • /
    • 1997
  • A disturbance rejection controller using eccentricity filtering and LQ control techniques is proposed to alleviate the effecto of major roll eccentricity in multivariable cold-rolling processes. Fundamental problems in multivariable cold-rolling processes such as process time delay inherent in exit thickness measurement and non-stationary characteristics of roll eccentricity signals can be overcome by the proposed control method. The filtered instantaneous estimate of roll eccentricity may be exploited to improve instantaneous estimate of the exit thickness variation based on roll force and roll gap measurements, and a feedforward compensator is augmented as a reference for a gaugemeter thickness estimator. LQ feedback controller is combined with eccentricity filter for the attenuation of the exit thickness variation due to the entry thickness variation. The simulation results show that the roll eccentricity disturbance is significantly eliminated and other disturbances also are attenuated.

A Study on the Control Model Identification and H(sub)$\infty$ Controller Design for Trandem Cold Mills

  • Lee, Man-Hyung;Chang, Yu-Shin;Kim, In-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.847-858
    • /
    • 2001
  • This paper considers the control model identification and H(sub)$\infty$ controller design for a tandem cold mill (TCM). In order to improve the performance of the existing automatic gauge control (AGC) system based on the Taylor linearized model of the TCM, a new mathematical model that can complement the Taylor linearized model is constructed by using the N4SID algorithm based on subspace method and the least squares algorithm based on ARX model. It is shown that the identified model had dynamic characteristics of the TCM than the existing Taylor linearized model. The H(sub)$\infty$ controller is designed to have robust stability to the system parameters variation, disturbance attenuation and robust tracking capability to the set-up value of strip thickness. The H(sub)$\infty$ servo problem is formulated and it is solved by using LMI (linear matrix inequality) techniques. Simulation results demonstrate the usefulness and applicability of the proposed H(sub)$\infty$ controller.

  • PDF

The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

The Properties of Microwave Propagation in Discharging Plasma (방전에 의한 프라즈마에서의 마이크로파 전파특성)

  • Yang, In-Eung;No, Bang-Hyeon;Kim, Bong-Yeol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.3
    • /
    • pp.31-39
    • /
    • 1968
  • In this paper microwave power propagated through the cold plasma was analyzed and measured with respect to the external magenetic flux density. The d. c discharge plasma was in the rectangular waveguide in which two electrode was inserted, and also the glass diseharge tube inserted in the ractangular wavegside. The direction of microwave pro-pagation, the axis of the discharge tube and external magnetic flux were perpendicular to each other. It showed that the attenuation and absorption of micro wave power propagated in the plasma was increased as the magnetic flux density, the discharge current and the pressure of the gas were increased.

  • PDF

Endoscopic Diagnosis, Treatment, and Follow-up of Serrated Polyps (톱니상 폴립의 내시경적 진단, 치료와 추적 관리)

  • Duk Hwan Kim
    • Journal of Digestive Cancer Research
    • /
    • v.11 no.1
    • /
    • pp.30-34
    • /
    • 2023
  • Since the 1990s, serrated polyps have been established to contribute to intermediate cancer development, and their importance has begun to be recognized. Serrated polyps are morphologically difficult to detect through endoscopy, and an effective resection method has not been established. Among serrated polyps, studies on sessile serrated lesions, with a relatively high risk of colorectal cancer transformation and detected with difficulty, are in progress. Studies to date describe the endoscopic features as mucus cap, surface debris or stool, attenuation of underlying vasculature, cloud-like surface, dark spots in crypts, and ill-defined irregular border. Additionally, it is expected that relatively large serrated polyps can be safely removed through cold snare resection. A plan for an effective management of serrated polyps through continuous research in the future is warranted.