• 제목/요약/키워드: coil number

검색결과 285건 처리시간 0.028초

Effective 3-D FEM for large-scale high temperature superconducting racetrack coil

  • Huang, Xiangyu;Huang, Zhen;Xu, Xiaoyong;Li, Wan;Jin, Zhijian
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권3호
    • /
    • pp.32-37
    • /
    • 2019
  • In various types of large-scale electrical applications, the number of coil turns in such machines is usually large. Electromagnetic simulation of large-scale superconducting coils (tens to hundreds of turns) is indispensable in the design process of superconducting electrical equipment. However, due to the large scale of the coil and the large aspect ratio of super-conducting material layer in HTS coated conductor, it is usually difficult or even unable to perform 3-D transient electromagnetic simulation. This paper introduces an effective 3-D electromagnetic simulation method for large-scale HTS coated conductor coil based on T-A formulation. The simulation and experimental results show that the 3-D model based on the T-A formulation using homogeneous strategy is more accurate than the traditional 2-D models. The memory usage is not sensitive to the number of turns and this model will be even more superior as the number of turns becomes larger.

Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

  • Kim, Myeong Jin;Lim, Yong Cheol;Oh, Se-Yang;Kim, Byung Moon;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권1호
    • /
    • pp.19-24
    • /
    • 2013
  • Objective : The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. Methods : From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. Results : Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was $5.0{\pm}8.7$ (mean${\pm}$SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was $2.1{\pm}5.4$ (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. Conclusion : The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.

코일건의 속도향상에 관한 연구 (Improving Speed of Coil Guns)

  • 박창형;김진호
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.118-123
    • /
    • 2018
  • Coil guns are known worldwide as inexpensive space launch vehicles. The principle of Fleming's right-hand rule allows the coil gun to accelerate the projectile by applying enormous voltage to the solenoid coil. This study was performed to improve the speed of the coil gun using MATLAB, a commercially available numerical program for high launching force of electromagnetic projectiles. To maximize the speed of the projectile, the largest coil of American wire gauge was used, and the number of windings in the radial and axial directions of the solenoid coil was optimized. Optimal length of the projectile was obtained by calculating the optimal aspect ratio between the axial length of the solenoid coil and the length of the projectile.

액체질소에 대한 증발 열전달 촉진 및 압력강하 성능 (Performance of Evaporation Heat Transfer Enhancement and Pressure Drop for Liquid Nitrogen)

  • 남상철;이상천;박병덕
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.363-372
    • /
    • 2000
  • An experiment was carried out to evaluate the heat transfer enhancement and the pressure drop characteristics for liquid nitrogen using wire-coil-insert technique under horizontal two-phase conditions. The tube inner diameters were 8 mm and 15 mm, respectively and the tube length was 4.7 m. The helix angle of the wire coil insert was $50^{\circ}$ and its length was 4.7 m. Heat transfer coefficients for both the plain and the enhanced test tubes were calculated from the measurements of temperatures, flow rates and pressure drops. A correlation in a power-law relationship of the Nusselt number, Reynolds number and Prandtl number for the heat transfer was proposed which can be available for design of cryogenic heat exchangers. The correlation showed that heat transfer coefficients for the wire-coil inserts were much higher than those for plain tubes, increased by more than $1.8{\sim}2.0$ times depending upon the range of the equivalent Reynolds number. The correlation was compared with other various correlations in the turbulent flow conditions.

헬리컬 코일 튜브에서의 층류, 천이, 난류 영역의 마찰계수에 대한 실험적 연구 (Experimental Study of Friction Factors for Laminar, Transition, and Turbulent Flow Regimes in Helical Coil Tubes)

  • 박원기;김태훈;도규형;한용식;최병일
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.7-15
    • /
    • 2018
  • The friction factors according to the flow regimes in helical coil tubes depend on the coil diameter, the tube diameter, and the coil pitch. In previous studies, correlations for the laminar flow regime in helical coil tubes have been proposed. However, studies on the transition flow regime and the turbulent flow regime are insufficient and further researches are necessary. In this study, characteristics of the friction factors for the laminar, transition and turbulent flow regimes in helical coil tubes were experimentally investigated. The helical coil tubes used in the experiments were made of copper. The curvature ratios of the helical coil tubes, which means the ratio of helical coil diameter to inner diameter of the helical coil tube are 24.5 and 90.9. Experiments were carried out in the range of $529{\leq}Re{\leq}39,406$ to observe the flows from the laminar to the turbulent regime. The friction factors were obtained by measuring the differential pressures according to the flow rates in the helical coil tubes while varying the curvature ratios of the helical coil tubes. Experimental data show that the friction factors for the helical coil tube with 24.5 in the curvature ratio of the helical coil tube were larger than those in the straight tube in all flow regimes. As the curvature ratio of the helical coil tube increases, the friction factor in turbulent flow regime tends to be equal to that of the straight tube. In addition, it was confirmed that the transition flow regimes in the helical coil tubes were much wider than those in the straight tube, also the critical Reynolds numbers were larger than those in the straight tube. The results obtained in this experimental study can be used as basic data for studies on the water hammer phenomenon in helical coil tubes.

원전 증기발생기 전열관 와전류검사용 보빈코일의 권선 수 변화에 대한 전기적 특성 연구 (A Study on Electrical Characteristics for Coil Winding Number Changes of Eddy Current Bobbin Coil for Steam Generator Tubes in NPPs)

  • 남민우;김철기
    • 비파괴검사학회지
    • /
    • 제32권1호
    • /
    • pp.64-70
    • /
    • 2012
  • 국내 원자력발전소 증기발생기 전열관의 건전성을 평가하기 위해서 수행되는 와전류검사의 탐촉자는 주로 두가지 종류가 사용한다. 첫 번째 와전류탐촉자는 마모와 같은 체적성 결함을 검사하기 위해 사용되는 보빈탐촉자이다. 두 번째 와전류탐촉자는 균열과 같은 비체적성 결함을 검사하기 위한 회전형 탐촉자이다. 와전류탐촉자는 검사 계통의 핵심적인 부분으로서 특정 절차서에 따라 평가가 이루어질 때 대상 시험체의 합부를 결정하는 자료를 제공하게 된다. 또한, 수집된 와전류신호의 품질은 사용되는 탐촉자의 설계특성, 기하학적 형태, 운전주파수에 따라 결정되고, 검사 결과에 미치는 영향이 크기 때문에 와전류검사 탐촉자의 선정은 특히 중요하다. 본 연구에서는 차동형 보빈탐촉자의 코일 권선 수의 변화가 탐촉자의 전기적 특성에 미치는 영향을 분석하였다. 이 결과를 이용하여 원전 증기발생기 전열관 와전류검사 보빈탐촉자를 설계하였다. 연구 결과 코일 권선 수의 변화는 전열관 형상 및 재질에 따른 검사주파수 선정에 크게 영향이 미침을 알 수 있다. 따라서 본 연구 결과를 통하여 원전 증기발생기 전열관 와전류검사 보빈탐촉자의 설계시 더욱 정밀한 코일 권선 수 설정에 토대를 구축하였다.

Nano-sec rise time을 갖는 Rogowski 코일의 제작 (CONSTRUCTION OF MEASURING ROGOWSKI COIL NANO-SEC RISR TIME)

  • 이용우;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.399-401
    • /
    • 1988
  • This paper describes the experiment and design of Rogowski - wound coil used to measure a pulsed current with pulsewidth on the order of 100nsec in the kiloampere range. Radius of coil is 2.75cm, total number of turns are 26 and cross -sectional area is 1 cm. The coil have 3ns rise time, 0.2nsec transit time and sensitivity is 4v/kA.

  • PDF

Simulation of ECT Bobbin Coil Probe Signals to Determine Optimum Coil Gap

  • Kong, Young-Bae;Song, Sung-Jin;Kim, Chang-Hwan;Yu, Hyung-Ju;Nam, Min-Woo;Jee, Dong-Hyun;Lee, Hee-Jong
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.403-410
    • /
    • 2006
  • Eddy current testing (ECT) signals produced by a differential bobbin coil probe vary according to probe design parameters such as the number of turns, geometry and coil gap size. In the present study, the characteristics of a differential bobbin coil probe signals are investigated by numerical simulation in order to determine the optimum coil gap. For verification of numerical simulation accuracy, a specially designed bobbin probe of which the coil gap can be adjusted is fabricated and a series of experiments to acquire signals from two kinds of standard tubes with the variation in coil gap is performed. Then, the experimental signals are compared to the simulation results. Based on this investigation, a decision on the optimum range of coil gap is made. The theoretically predicted signals agree very well to the experimental signals. In fact, this excellent agreement demonstrates a high potential of the simulation as a design optimization tool for ECT bobbin probes.

와이어코일 삽입법을 이용한 열전달 촉진기술 성능평가 (Evaluation of Heat Transfer performance of Wire-coil Inserted Tube)

  • 이주동;박종호;이상천
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.457-465
    • /
    • 2000
  • An experiment was carried out to evaluate the thermal performance of the wire-coil inserts method. Tested were the smooth tubes with the wire-nil inserts of various pitch and helix angle combinations. Test fluids were the 50%-solution of the ethylene glycol and the Hue water. Heat transfer coefficient and friction factors were deduced from the measured values of temperatures, flowrates and pressure drops. A unified dimensionless correlation for the heat transfer coefficients was developed as a function of the pitch to diameter ratio, the Reynolds number and the Prandtl number. An exergy analysis was performed to evaluate an optimal operating condition with the wire-coil inserts.

  • PDF

투자율이 높은 NiFe 코어를 이용한 마이크로 트랜스포머 제작 (Fabrication of the Micromachined Transformer using High Permeability NiFe Core)

  • 조세준;차두열;이재혁;이수진;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.194-198
    • /
    • 2010
  • Recently as the electronic devices are getting to be more and more smaller, transformers are needed to be micro fabricated using MEMS technology. In this paper transformers have been fabricated and measured by depositing insulation layer to reduce the loss of eddy current and in the middle core a high permeability permalloy was designed based on the turns ratio between primary coil and secondary coil which are 1:1 transformers. (the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7). The size of the transformers including ground shield are $1mm{\times}1.5mm$, $1mm{\times}1.95mm$, $1mm{\times}2.35mm$ respectively. The line width, pitch and the height of post are 50um. Based on the measured data from the micro fabricated transformers, the 3/3 turns in the primary coil and secondary coil showed the lowest insertion loss with 1.5 dB at 480 MHz and the 7/7 turns in the primary coil and secondary coil showed the highest insertion loss with 2.5 dB at 280 MHz. Also confirmed that the bandwidth goes up as the number of turns goes down. There was some difference between the actual measured data and the HFSS simulation result. It looks as if it is an error of the difference between oxidation of copper or the permeability of SU-8.