• Title/Summary/Keyword: coil number

Search Result 287, Processing Time 0.032 seconds

Development of Control Algorithm and Pick & Placer (반도체 소자 Pick &Placer 및 제어 알고리즘 개발)

  • 심성보;김재희;유범상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1339-1343
    • /
    • 2004
  • This paper presents a development of the control algorithm and Pick & Placer. The Pick & Placer provides a powerful multi-task system that includes both graphical and remote interface. Users can easily set up sorting parameters and record important data including wafer number, data, and operator information. This System sets up a dustproof device and massively machined components to provide an extremely stable sorting environment. Precise resolution and accuracy result from using machine vision, a pneumatic slide drive and close -looped positioning.

  • PDF

Homogeneous Magnet Design Technique Using Linear Programming (리니어프로그래밍을 이용한 균등자장 발생용 마그네트의 최적설계)

  • Lee, Sang-Jin;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.590-592
    • /
    • 2001
  • We introduce a technique for designing homogeneous magnets using linear programming. The method has several advantages over existing techniques including: it allows complete flexibility in arbitrary geometric constraints on both the coil locations and the shape of the homogeneous volume; it guarantees a globally optimal solution, and it automatically choose the minimum number of coils necessary for the constraints.

  • PDF

A Numerical Study on the Operation of Cooling System in an Office Building (사무소용 건물의 냉방시스템 운전에 관한 수치적 연구)

  • Lee, Seung Woo;Min, Man Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.6
    • /
    • pp.686-695
    • /
    • 1988
  • An algorithm and a computer program were developed for the operational simulation of office building cooling system. Using this computer program, the following results were obtained. ${\bullet}$ There is a critical number of coil rows in AHU with which the cooling system can be operated in maximum efficiency. ${\bullet}$ Energy conservation can be achieved in an office building through TAB(Testing Adjusting and Balancing) of zone air volumes.

  • PDF

Homogeneous Magnet Design Technique Using Evolution Strategy (진화알고리즘을 이용한 균즐자장 발생용 마그네트의 최적설계)

  • 송명곤;김동훈;이상진
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.114-118
    • /
    • 2002
  • We introduce a design technique for homogeneous magnets using evolution strategy. The method has several advantages over existing techniques including: it allows complete flexibility in geometric constraints on the shape of both the coil and the homogeneous volume; it guarantees a globally optimal solution, and it automatically searches the minimum number of coils that satisfies given constraints.

Development of 2W-Level Wireless Powered Energy Harvesting Receiver using 60Hz power line in Electricity Cable Tunnel (전력구 내 지중선을 이용한 2W급 상용주파수 무선전력 수신장치 개발)

  • Jang, Gi-Chan;Choi, Bo-Hwan;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.296-301
    • /
    • 2016
  • Using high magnetic flux from a 60 Hz high-current cable, a 2 W wireless-powered energy harvesting receiver for sensor operation, internet of things (IoT) devices, and LED lights inside electrical cable tunnels is proposed. The proposed receiver comprises a copper coil with a high number of turns, a ring-shaped ferromagnetic core, a capacitor for compensating for the impedance of the coil in series, and a rectifier with various types of loads, such as sensors, IoT devices, and LEDs. To achieve safe and easy installation around the power cable, the proposed ring-shaped receiver is designed to easily open or close using a clothespin-shaped handle, which is made of highly-insulated plastic. Laminated silicon steel plates are assembled and used as the core because of their mechanical robustness and high saturation flux density characteristic, in which the thickness of each isolated plate is 0.3 mm. The series-connected resonant capacitor, which is appropriate for low-voltage applications, is used together with the proposed receiver coil. The concept of the figure of merit, which is the product weight and cost of both the silicon steel plate and the copper wire, is used for an optimized design; therefore, the weight of the fabricated receiver and the price of raw material is 750 gf and USD $2 each, respectively. The 2.2 W powering capability of the fabricated receiver was experimentally verified with a power cable current of $100A_{rms}$ at 60Hz.

Effect of Plasma Density on the Tribological Properties of Amorphous Carbon Thin Films (비정질 탄소박막의 트라이볼로지 특성에 미치는 플라즈마 밀도의 영향)

  • Park, Y.S.;Lee, J.D.;Hong, B.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.333-338
    • /
    • 2011
  • In this work, we have fabricated the amorphous carbon (a-C:H) thin film by using unbalanced magnetron sputtering method with the magnetron source of inside/outside electromagnetic coils as the protective coating materials. We have investigated the tribological properties of amorphous carbon films prepared with various electromagnetic coil currents for the change of the plasma density, such as hardness, friction coefficient, adhesion, and surface roughness. Raman and HRTEM were used to study the microstructure of carbon films. In the result, the hardness and adhesion properties of a-C:H films were improved with increasing electromagnetic coil current due to the increase of the plasma density to the substrate. Thus, these results can be explained by the increase of $sp^2$ bonding and cluster number in the amorphous carbon film, related to the improved bombardment around substrate and the increased substrate temperature.

Benefits of Surgical Treatment for Unruptured Intracranial Aneurysms in Elderly Patients

  • Jang, E-Wook;Jung, Jin-Young;Hong, Chang-Ki;Joo, Jin-Yang
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Objective: Due to longer life spans, patients newly diagnosed with unruptured intracranial aneurysms (UIAs) are increasing in number. This study aimed to evaluate how management of UIAs in patients age 65 years and older affects the clinical outcomes and post-procedural morbidity rates in these patients. Methods: We retrospectively reviewed 109 patients harboring 136 aneurysms across 12 years, between 1997 and 2009, at our institute. We obtained the following data from all patients: age, sex, location and size of the aneurysm(s), presence of symptoms, risk factors for stroke, treatment modality, and postoperative 1-year morbidity and mortality. We classified these patients into three groups: Group A (surgical clipping), Group B (coil embolization), and Group C (observation only). Results: Among the 109 patients, 56 (51.4%) underwent clipping treatment, 25 (23%) patients were treated with coiling, and 28 observation only. The overall morbidity and mortality rates were 2.46% and 0%, respectively. The morbidity rate was 1.78% for Clipping and 4% for coiling. Factors such as hypertension, diabetes mellitus, hypercholesterolemia, smoking, and family history of stroke were correlated with unfavorable outcomes. Two in the observation group refused follow-up and died of intracranial ruptured aneurysms. The observation group had a 7% mortality rate. Conclusion: Our results show acceptable favorable outcome of treatment-related morbidity comparing with the natural history of unruptured cerebral aneurysm. Surgical clipping did not lead to inferior outcomes in our study, although coil embolization is generally more popular for treating elderly patients, In the treatment of patients more than 65 years old, age is not the limiting factor.

Aneurysmal Neck Clipping as the Primary Treatment Option for Both Ruptured and Unruptured Middle Cerebral Artery Aneurysms

  • Choi, Jai Ho;Park, Jung Eon;Kim, Myeong Jin;Kim, Bum Su;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.269-275
    • /
    • 2016
  • Objective : Although middle cerebral artery (MCA) aneurysms are less amenable to coil embolization, an increasing number of studies support favorable endovascular treatment for them. The purpose of this study is to compare the outcomes of two different treatments (surgery versus coiling) and evaluate the benefits of surgical clipping for MCA aneurysms. Methods : Here we retrospectively analyzed the outcomes of 178 ruptured and unruptured MCA aneurysms treated in patients between September 2008 and April 2012. Parameters assessing treatment outcomes include degree of aneurysm occlusion, presence of regrowth, clinical status, and complications. Results : Among 178 MCA aneurysms, 153 were treated surgically. After a mean follow-up of 12 months, the surgery group showed a clinically significant complete occlusion rate (98%) compared with the coiling group (56%) (p<0.001). Follow-up radiologic evaluation showed a higher regrowth rate (four of 16 cases) in the coiling group than in the surgery group (one of 49 cases) (p=0.003). There was no statistically significant difference in favorable clinical outcome rate between the two groups. The procedure-related permanent morbidity and mortality rates were 2% (three of 153 cases) in the surgery group and 0% (0 of 25 cases) in the coiling group. Conclusion : Compared to endovascular treatment, surgical neck clipping for both ruptured and unruptured MCA aneurysms results in a significantly higher complete obliteration rate and less regrowth. Therefore, even in this endovascular era, we still recommend surgical clipping as the primary treatment option for MCA aneurysms rather than coil embolization.

Design of Epitaxy Style Magnetic Curer and Special Quality Embodiment for Nerve Luman Nature Disease Treatment (신경인성 질환치료를 위한 적층형 자기치료기의 설계 및 특성구현)

  • Lee, Jung-Sook;Kim, Whi-Young
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.2
    • /
    • pp.157-174
    • /
    • 2007
  • Result that study to serve to apply epitaxy style magnet nerve curer in nerve human nature disease treatment is as following. Designed probe actually with special quality research about coil probe of magnet curer firstly. Impose and revealed all drives about treatment probe embodying power device using MOSFET that is electric power element secondly. Could receive energy value that is proportional in number to close with actuality coil value by manufacture about treatment coil probe by third and come out. This could embody treatment pulse by disease, and saved pulse third and so on by damping pulse form through a special quality experiment variously specially. High amplitude treatment pulse(great strong) maximizes curative effect at short time and will be bought that demand is magnified greatly at the future in this research.

  • PDF

Electromagnetic Forming Process Analysis Based on Coupled Simulations of Electromagnetic Analysis and Structural Analysis

  • Lee, Man Gi;Lee, Seung Hwan;Kim, Sunwoo;Kim, Jin Ho
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.215-221
    • /
    • 2016
  • We conducted a phased electromagnetic forming process analysis (EFPA) over time through a coupling of electromagnetic analysis and structural analysis. The analysis is conducted through a direct linkage between electromagnetic analysis and structural analysis. The analysis process is repeated until the electric current is completely discharged by a formed coil. We calculate the forming force that affects the workpiece using MAXWELL, a commercial electromagnetic finite element analysis program. Then, we simulate plastic behavior by using the calculated forming force data as the forming force input to ANSYS, a commercial structure finite element analysis program. We calculate the forming force data by using the model shape in MAXWELL, a commercial electromagnetic finite element analysis program. We repeat the process until the current is fully discharged by the formed coil. Our results can be used to reduce the error in data transformation with a reduced number of data transformations, because the proposed approach directly links the electromagnetic analysis and the structural analysis after removing the step of the numerical analysis of a graph describing the forming force, unlike the existing electromagnetic forming process. Second, it is possible to simulate a more realistic forming force by keeping a certain distance between nodes using the re-mesh function during the repeated analysis until the current is completely discharged by the formed coil, based on the MAXWELL results. We compare and review the results of the EFPA using the peak value of the forming force that acts on the workpiece (which is the existing analysis method), and the proposed phased EFPA over time approach.