• Title/Summary/Keyword: coil

Search Result 3,847, Processing Time 0.028 seconds

A Study on The Development of High-Efficiency Transmitting and Receiving Coils For Wireless Charging of Drones (드론 무선 충전을 위한 고효율 송, 수신 코일 개발에 관한 연구)

  • Lim, Jong-Gyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.213-218
    • /
    • 2022
  • In this paper, a technology for a high-efficiency wireless power transmission transmitting and receiving coil that can wirelessly charge a drone is introduced. The drone station implements the ability to charge the battery wirelessly without the need to remove the battery to charge the drone's battery. In order to charge the drone's battery in the shortest time, wireless charging efficiency must be high. In order to increase the wireless charging efficiency of the drone station, a method for manufacturing high-efficiency transmitting and receiving coils and a performance measurement method are presented. Transmitting and receiving coils were manufactured considering the size and weight of the drone so as not to interfere with the flight of the drone. Efficiency of 88% or more was realized at a distance of 40mm or more between the transmitting and receiving coils.

Compensation of low Frequency Resonance in Current Driven Loudspeakers using DSP (DSP를 이용한 전류구동 스피커의 저주파 공진 보상)

  • Park, Jong-phil;Eun, Changsoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.584-588
    • /
    • 2021
  • The impedance of the speaker is likely to be recognized as a fixed value. However, speaker impedance continues to vary with frequency variation, especially larger in resonant frequency region. The sound pressure level of loudspeakers is determined by the current flowing throughout the coil that consists loudspeakers. If loudspeakers are driven by voltage, sound pressure level of the loudspeaker is distorted by the variation of loudspeaker impedance. Current-drive of loudspeakers can solve this problem, but distortion of sound pressure level occurs in low frequencies due to resonance. The distortion can degrade the sound quality of the sound system. So to solve this problem, In this paper, we propose a resonance compensation circuit using DSP. we simulates audio systems using an equivalent model of loudspeakers to verify distortion of sound pressure level due to impedance variation and propose a circuit to compensate it. The proposed circuit is configured using a state variable filter and it can adjust the center frequency and output, so it will be used various sound systems.

  • PDF

Fiber Based Supercapacitors for Wearable Application (웨어러블 응용을 위한 섬유형 슈퍼커패시터)

  • Jae Myeong Lee;Wonkyeong Son;Juwan Kim;Jun Ho Noh;Myoungeun Oh;Jin Hyeong Choi;Changsoon Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.303-325
    • /
    • 2023
  • Flexible fiber- or yarn-based one-dimensional (1-D) energy storage devices are essential for developing wearable electronics and have thus attracted considerable attention in various fields including ubiquitous healthcare (U-healthcare) systems and textile platforms. 1-D supercapacitors (SCs), in particular, are recognized as one of the most promising candidates to power wearable electronics due to their unique energy storage and high adaptability for the human body. They can be woven into textiles or effectively designed into diverse architectures for practical use in day-to-day life. This review summarizes recent important development and advances in fiber-based supercapacitors, concerning the active materials, fiber configuration, and applications. Active materials intended to enhance energy storage capability including carbon nanomaterials, metal oxides, and conductive polymers, are first discussed. With their loading methods for fiber electrodes, a summary of the four main types of fiber SCs (e.g., coil, supercoil, buckle, and hybrid structures) is then provided, followed by demonstrations of some practical applications including wearability and power supplies. Finally, the current challenges and perspectives in this field are made for future works.

In silico annotation of a hypothetical protein from Listeria monocytogenes EGD-e unfolds a toxin protein of the type II secretion system

  • Maisha Tasneem;Shipan Das Gupta;Monira Binte Momin;Kazi Modasser Hossain;Tasnim Binta Osman;Fazley Rabbi
    • Genomics & Informatics
    • /
    • v.21 no.1
    • /
    • pp.7.1-7.11
    • /
    • 2023
  • The gram-positive bacterium Listeria monocytogenes is an important foodborne intracellular pathogen that is widespread in the environment. The functions of hypothetical proteins (HP) from various pathogenic bacteria have been successfully annotated using a variety of bioinformatics strategies. In this study, a HP Imo0888 (NP_464414.1) from the Listeria monocytogenes EGD-e strain was annotated using several bioinformatics tools. Various techniques, including CELLO, PSORTb, and SOSUIGramN, identified the candidate protein as cytoplasmic. Domain and motif analysis revealed that the target protein is a PemK/MazF-like toxin protein of the type II toxin-antitoxin system (TAS) which was consistent with BLASTp analysis. Through secondary structure analysis, we found the random coil to be the most frequent. The Alpha Fold 2 Protein Structure Prediction Database was used to determine the three-dimensional (3D) structure of the HP using the template structure of a type II TAS PemK/MazF family toxin protein (DB ID_AFDB: A0A4B9HQB9) with 99.1% sequence identity. Various quality evaluation tools, such as PROCHECK, ERRAT, Verify 3D, and QMEAN were used to validate the 3D structure. Following the YASARA energy minimization method, the target protein's 3D structure became more stable. The active site of the developed 3D structure was determined by the CASTp server. Most pathogens that harbor TAS create a crucial risk to human health. Our aim to annotate the HP Imo088 found in Listeria could offer a chance to understand bacterial pathogenicity and identify a number of potential targets for drug development.

Quantitative Evaluation of Wear Resistance of Stamping Tool with Respect to Hardness of Tool Materials in Cold Stamping of TRIP1180 Steel Sheets (TRIP1180 판재의 냉간 스탬핑공정에서 금형강의 경도 특성에 따른 내마모성 평가)

  • Bang, J.H.;Bae, G.;Song, J.H.;Kim, H.G.;Lee, M.G.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.129-135
    • /
    • 2022
  • The purpose of this study was to quantitatively evaluate the influence of hardness of tool materials on wear resistance in the sheet metal forming process. Punches used in the wear test were made of STD-11 and K340 tool material, and the tempering temperature was set to 530℃ and 500℃, respectively, to control the hardness of the tool materials. The punches mimic the shape of stamping tool of automotive body component to reflect its plastic deformation, and are designed to concentrate wear on the curvature region of punches. Progressive die and coil sheet were used to save time, cost, and raw sheet materials. By quantitatively measuring the wear depth of the punches, the wear behavior and mechanism of the punches were investigated, and characteristics of hardness and wear resistance according to tool materials and tempering temperatures were evaluated. Testing results indicate that the punch made of K340 tool steel with higher hardness had better wear resistance than that of STD-11 tool steel, and the hardness and wear resistance of tool steel were significantly impacted by the tempering temperature.

Effect of Several Native Moss Plants on Particulate Matter, Volatile Organic Compounds and Air Composition

  • Gong, Gyeong Yeop;Kang, Ji Su;Jeong, Kyeong Jin;Jeong, Jun Ho;Yun, Jae Gill
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • Experiments were carried out to investigate the effects of mosses on the removal of particulate matter (PM 10) and volatile organic compounds (VOCs) in an indoor space and on the composition of air. For particulate matter removal experiments, 0.2 g mosquitto coil was burned in a glass chamber, where three kinds of mosses (Plagiomnium cuspidatum, Myuroclada maximowiczii, Etodon luridus) were placed. For VOCs removal experiments, 1 mL paint thinner was volatilized in a glass chamber, where Plagiomnium cuspidatum and Myuroclada maximowiczii were used. As a result, it was found that particulate matter was effectively removed by the three mosses, and the removal efficiency of particulate matter increased as the amount of mosses increased. The amount of VOCs was similar to the level in the control when a low amount of mosses (2 and 4 plates) was used. However, the removal efficiency of VOCs was significant when 6 plates of mosses were used. On the other hand, formaldehyde concentration was 40 times more than the control and carbon monoxide 30 times, when 0.2 g of mosquito repellent was completely burned in a glass chamber. Also formaldehyde removal effect was significant when 6 plates of mosses were placed. However, there was no change in the concentration of indoor oxygen, temperature and humidity by moss plants. In conclusion, the moss plants were effective in removing particulate matter and VOCs, and they are expected to be used for indoor decoration and landscape in order to improve indoor air quality in the future.

Identification of Void Diameters for Cast-Resin Transformers (몰드변압기의 보이드 결함 크기 판별)

  • Jeong, Gi-woo;Kim, Wook-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.570-573
    • /
    • 2022
  • This paper presents the identification of void diameters for a cast-resin transformer using an artificial neural network (ANN) model. A PD signal was measured by the Rogowski coil sensor which has the planar and thin structures fabricated on a printed circuit board (PCB), and the PD electrode system was fabricated to simulate a PD defect by a void. In addition, void samples with different diameters were fabricated by injecting air in a cylindrical aluminum frame using a syringe during the epoxy curing process. To identify the diameter of void defects, PD characteristics such as the discharge magnitude, pulse count, and phase angle were extracted and back propagation algorithm (BPA) was designed using virtual instrument (VI) based on the Labview program. From the experimental results, the BPA algorithm proposed in this paper has over 90% accurate rate to identify the diameter of void defects and is expected to use reference data of maintenance and replacement of insulation for cast-resin transformers in the on-site PD measurement.

  • PDF

Silent Embolic Infarction after Neuroform Atlas Stent-Assisted Coiling of Unruptured Intracranial Aneurysms

  • Seungho Shin;Lee Hwangbo;Tae-Hong Lee;Jun Kyeung Ko
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.42-49
    • /
    • 2024
  • Objective : There is still controversy regarding whether neck remodeling stent affects the occurrence of silent embolic infarction (SEI) after aneurysm coiling. Thus, the aim of the present study is to investigate the incidence of SEI after stent-assisted coiling (SAC) using Neuroform Atlas Stent (NAS) and possible risk factors. This study also includes a comparison with simple coiling group during the same period to estimate the impact of NAS on the occurrence of SEI. Methods : This study included a total of 96 unruptured intracranial aneurysms in 96 patients treated with SAC using NAS. Correlations of demographic data, aneurysm characteristics, and angiographic parameters with properties of SEI were analyzed. The incidence and characteristics of SEI were investigated in 28 patients who underwent simple coiling during the same period, and the results were compared with the SAC group. Results : In the diffusion-weighted imaging obtained on the 1st day after SAC, a total of 106 SEI lesions were observed in 48 (50%) of 96 patients. Of these 48 patients, 38 (79.2%) had 1-3 lesions. Of 106 lesions, 74 (69.8%) had a diameter less than 3 mm. SEI occurred more frequently in older patients (≥60 years, p=0.013). The volume of SEI was found to be significantly increased in older age (≥60 years, p=0.032), hypertension (p=0.036), and aneurysm size ≥5 mm (p=0.047). The incidence and mean volume of SEI in the SAC group (n=96) were similar to those of the simple coiling group (n=28) during the same period. Conclusion : SEIs are common after NAS-assisted coiling. Their incidence in SAC was comparable to that in simple coiling. They occurred more frequently at an older age. Therefore, the use of NAS in the treatment of unruptured intracranial aneurysm does not seem to be associated with an increased risk of thromboembolic events if antiplatelet premedication has been performed well.

Treating Sudden Onset Hepatic Encephalopathy with Coil Embolization in a Patient with a Congenital Intrahepatic Portosystemic Venous Shunt: A Case Report (갑자기 간성뇌증이 발생한 선천성 간내 문맥정맥단락 환자의 코일 색전술 치료: 증례 보고)

  • Yeonsoo Choi;Jin Hyeok Kim;Ung Bae Jeon;Joo Yeon Jang;Tae Un Kim;Hwaseong Ryu
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1426-1431
    • /
    • 2022
  • Intrahepatic portosystemic venous shunt (IPSVS) is a rare vascular abnormality that involves abnormal communication between the intrahepatic portal vein and systemic veins, such as the hepatic vein or inferior vena cava. Patients with IPSVS are typically asymptomatic, and IPSVS is incidentally discovered via imaging while evaluating other diseases. However, endovascular closure of the shunt should be considered in symptomatic patients with a high-flow shunt. This report presents a patient with congenital IPSVS with sudden onset hepatic encephalopathy treated using percutaneous transhepatic embolization.

Endovascular Treatment of a Systemic-to-Pulmonary Artery Fistula: A Case Report (체-폐동맥루의 혈관 내 치료: 증례 보고)

  • Eunbyul Lee;Dong Jae Shim;Doyoung Kim;Jung Whee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.682-687
    • /
    • 2021
  • Systemic-to-pulmonary artery fistulas are rare. This condition may be congenital, post-traumatic, or post-inflammatory and can cause infection, hemorrhage, or pulmonary hypertension. Here, we report a case of an intercostal-to-pulmonary artery fistula, incidentally detected during the evaluation of dyspnea in a 67-year-old female. Retrograde transcatheter coil embolization in a dilated draining pulmonary artery was initially attempted. However, another draining pulmonary artery developed after 5 months. The intercostal arteries or systemic feeders were successfully embolized through a transarterial access. At the 10-month follow-up, the abnormally dilated vessels had regressed, and dyspnea had improved. Sequential or simultaneous retro- and antegrade transcatheter embolization may successfully treat pleural arterio-arterial fistulas.