• 제목/요약/키워드: coil

검색결과 3,835건 처리시간 0.047초

밸브구동용 보이스 코일 선형 포스모터 설계와 해석 연구 (A Study on the Design and Analysis of a Voice Coil Linear Force Motor for Hydraulic Valve)

  • 박창순;허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.1-7
    • /
    • 2012
  • The voice coil linear force motor is a kind of a direct drive motion device that uses a permanent magnetic field and coil winding to produce force. In order to design a voice coil linear force motor, an exact calculations of the required force, the flux density in air gap and the flux pathway are needed. A conventional method can be used usually to calculate the flux density in air gap, but with this method it is needed to find a magnetic circuit revision constant. In this paper a voice coil linear force motor is designed by conventional design method and analyzed by 3D simulation program "Flux". For the prototype linear force motor, the results of the calculated by conventional design method and the analyzed by 3D simulation program are compared with the test result. Finally it is showed that the magnetic circuit revision constant which is found by comparing of the analyzed and the measured data can be used for the design of the voice coil type linear force motor to minimize the trial and error.

Design and Test Results of an Actively Shielded Superconducting Magnet for Magnetic Resonance Imaging

  • Jin, Hong-Beom;Ryu, Kang-Sik;Oh, Bong-Hwan;Ryu, Kyung-Woo;Jeoun, In-Young
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.95-105
    • /
    • 1997
  • In this paper, we have studied about design and fabrication of the actively shielded superconducting MRI magnet. Nonlinear optimization methods are usually used to find optimum coil configurations. However the selection of initial coil configurations is very difficult. In case bad initial data are used, it is even impossible to find optimum coil configurations which satisfy predefined constraints. We have developed computer optimization program which consists of two steps. Initial coil configurations are easily selected through linear optimization in the first step and optimum coil configurations are found through nonlinear optimization in the second step. We have also studied about superconducting shim coils to cancel error fields caused by coil fabrication errors. Many researchers published design concepts of shim coil. However all these studies are for shim coil design using filamentary coils with single turn, Shim coils with multi-turns should be used to produce enough field strength to cancel error fields. We have developed computer program for the design of shim coils which have proper thickness and length. An actively shielded superconducting MRI magnet with a small warm bore was fabricated and four sets of superconducting shim coils were equipped. The magnetic field distributions were measured and field correction was carried out using shim coils.

  • PDF

자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구 (The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit)

  • 지근양;민경일;이수원;장봉환;문영현
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

13.2kV/630A급 고온초전도 한류코일 개발 (Development of 13.2kV/630A High-Tc Superconducting Fault Current Limiting Coil)

  • 이찬주;강형구;남관우;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.943-944
    • /
    • 2007
  • In this paper, the development and the test of 13.2kV/630A high-Tc superconducting fault current limiting coil are described. The fault current limiting coil made of Coated Conductor (CC) was fabricated with bifilar winding method for non-inductive characteristics and tested in the distribution power system level in Dec. 2006. In order to determine the length of the superconducting coil, applied voltage per unit length(V/m) was studied analytically and it was verified through experiments. For the volume minimization, the coil was designed with concentrical arrangement method. The short-circuit test was performed with the prospective fault current of asymmetrical 10kA whose maximum fault current was $30kA_{peak}$. In the test, the voltage drop and the current of the coil were measured and the resistance of the coil was obtained. Also, the temperature rise of the coil was calculated with the relationship between the resistance and the temperature of CC. In this paper, the experimental results are analyzed and compared with the simulation.

  • PDF

편향요크코일의 에나멜 탈피 및 통전성형을 위한 탈피통전기의 개발 (Development of the controller for peeling off the enamel and forming of deflection yoke coil)

  • 정수화;윤종순;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.202-205
    • /
    • 1995
  • Developed controller is the part of deflection yoke winding machine which controls the power to form the deflection yoke coil into desired shape after winding. So as to form the deflection yoke coil, it is needed to melt the bonding material which is spreaded on the coil. The heat melt the bonding material which is produced by flowing the current through the winded coil. Therefore, at first it is needed to peel off the enamel from the winded coil so as to flow the current, and then supply the power to produce the heat which form the winded coil into desired shape. Naturally developed controller is composed of the peeling part and the conduction and forming part. All of them consist of the inverter structure and control the output current. The peeling is achieved by low voltage and high AC current, the conduction and forming is by DC current. Developed controller also has a function that detect the resistance of the deflection yoke coil to prevent the damage of the load which is produced by poor peeling.

  • PDF

Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향 (Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force)

  • 이규선;이선경;김복동
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.

척추 MRI를 위한 One-Channel Phased-Array Quadrature RF 코일 (One-Channel Phased-Array Quadrature RF Coil for Spine Magnetic Resonance Imaging)

  • 양윤정;김선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.129-132
    • /
    • 1998
  • 이 논문의 목적은 척추 영상을 위한 One-channel phased-array quadrature RF 코일을 개발하는 것이다. 두 개의 수직방향 RF 코일을 조합하여 만든 Quadrature RF코일은 한 개의 코일을 쓰는 것에 비해 배의 signal-to-noise ratio(SNB) 향상을 얻울 수 있다. Phased-array quadrature RF 코일에서는 코일 element의 크기를 줄임으로써 SNR을 더욱 향상시킬 수 있다. 이에 따라 줄어드는 코일의 Coverage를 유지하기 위해 phased-array 코일에서는 여러 set의 작은 코일을 사용한다. 다음과 같은 두가지 방법으로 Phased-array의 각 코일간의 간섭 현상을 제거했으며 SNR을 개선하였다. (1)인접한 코일을 적당한 간격으로 겹쳐지게 함으로써 상호 인덕턴스를 영으로 만든다. (2)Pro-amp를 코일에 바로 붙임으로써 커플링 회로에서의 SNR loss를 방지하고 그 다음 단에서 코일 사이의 phase차를 보정한다. 이 논문에서는 Receive-only mode의 Phased-array quadrature RF 코일을 개발하여 팬텀과 인체 척추의 영상촬영을 통하여 그 성능을 입증하였다.

  • PDF

전산해석을 통한 전대뇌동맥류 코일 색전술 후 혈류 유동 분석 (Analysis of Blood Flow after Coil Embolization in Anterior Cerebral Artery Aneurysm)

  • 김동휘;윤정훈;이창용;제준우;김동민;배영오;황진율
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.80-93
    • /
    • 2023
  • We performed numerical simulations of blood flow in an arterial cerebral artery aneurysm to investigate the hemodynamic behavior after coil embolization. A patient-specific model was created based on CTA data. We also conducted the coil embolization simulation to obtain the coil placement within the aneurysm. Blood was assumed to be an incompressible Newtonian fluid, and both the vessel and coil were considered rigid walls. The pulsatile boundary condition was applied at the inlet, and the outflow boundary conditions were used at the outlets. Our findings demonstrated that the coil embolization significantly reduces the blood volume flowrate entering the aneurysm by effectively blocking the inflow jet, leading to a decrease in both TAWSS and WSS, especially at the systolic peak in the impingement zone. While several high OSI regions disappeared over the aneurysm surface, we observed high OSI regions with a relatively small area where the coil did not completely occlude the aneurysm. Overall, these results quantitatively analyzed the effectiveness of coil embolization by focusing on hemodynamic indicators, potentially preventing aneurysm rupture. The present work could contribute to the development of patient-specific coil embolization.

Synthetic MR을 이용한 정량적 평가에서 Coil channel 수 변화에 따른 재현성 평가 (Evaluation of Reproducibility According to Variation of Coil Channel in Quantitative Evaluation Using Synthetic MR)

  • 권순용;김성호
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.343-351
    • /
    • 2017
  • 최신 영상 기법인 MAGiC sequence의 RF coil channel 수 변화에 따른 T1, T2 이완 시간 및 T1, T2 이완율을 측정하여 분석하였고 그에 따른 재현성을 평가하였다. Channel 수가 각각 (1, 8, 16, 32)channel 인 RF coil에 조영제 phantom(1.0, 0.6, 0.2, 0mM)을 위치시키고 MAGiC sequence를 이용하여 T1, T2, R1, R2 map을 획득하였다. 그리고 각각의 channel 수와 농도별로 T1, T2, R1, R2 value 그리고 relaxation rate를 측정하였고 이를 기반으로 각 농도에 따른 Relaxivity를 구하였다. 각각의 coil에서 T1, T2, R1, R2 value를 측정한 결과 T1, R1 value는 coil간의 유의한 차이가 없었다(p>0.05). 하지만 T2, R2 value는 유의한 차이가 있는 것으로 나타났다(p<0.05). 사후분석 결과에서는 T2 value의 경우 1 channel coil에서 측정한 결과가 8, 16, 32 channel coil에서 측정한 결과와 유의한 차이가 나타났고(p<0.05) 8, 16, 32 channel coil간의 차이는 나타나지 않았다(p>0.05). R2 value의 경우도 마찬가지로 1 channel coil에서 측정한 결과가 8, 16, 32 channel coil에서 측정한 결과와 유의한 차이가 나타났으며 또한 8 channel coil에서 측정한 결과와 16 channel coil에서 측정한 결과가 유의한 차이가 나타났다(p<0.05). 결론적으로 T1, R1 value는 coil의 channel 수 변화에 따른 차이가 크지 않지만 T2, R2 value는 큰 차이를 나타냈다. 따라서 MAGiC sequence를 이용하여 T2, R2 value를 정량적으로 측정할 경우 재현성을 위해 동일한 channel 수의 coil을 사용해야 할 것으로 사료된다.

FDTD 방법을 이용한 MRI Birdcage RF Coil의 Endcap 효과 분석 (Analysis of Endcap Effect for MRI Birdcage RF Coil by FDTD Method)

  • 정성택;박부식;신윤미;곽준식;조종운;김경남
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.137-143
    • /
    • 2003
  • 목적 : 자기공명영상(MRI)에서 두부영상촬영을 위하여 가장 많이 사용되는 birdcage RF (Radiofrequency) 코일의 RF B1 필드가 코일 중앙부에서 endring영역으로 갈수록 줄어드는 것을 볼 수 있다. Birdcage RF 코일에서 endcap 쉴드가 코일 중앙부에서 endring영역으로 갈수록 RF B1 필드 균질성에 얼마나 영향을 주는지에 대하여 분석하였다. 대상 및 방법 : Lowpass, highpass, hybrid birdcage RF 코일들에 대해 각각 FDTD (Finite Difference Time Domain) 모의실험으로 RF B1 자속밀도 분포를 비교하였다. 모의 실험결과 RF Bl 필드가 가장 높은 조건인 highpass birdcage RF코일을 선택하여 RF코일 endring 근처에 endcap 쉴드를 적용함으로써 RF B1 균질성에 얼마나 영향이 있는 지 조사하였다. 결과 : FDTD모의실험결과 highpass birdcage RF코일은 코일 내부에서 RF B1 필드가 lowpass나 hybrid 형태의 birdcage RF 코일들 보다 우수하나 코일 중앙부에서 endring 영역까지의 균질성은 떨어졌다. 그러나 highpass birdcage RF 코일에 endcap 쉴드를 적용하면 hybrid birdcage RF 코일의 RF B1 필드와 비슷한 수준이면서 sagittal 방향의 전체적인 RF B1 균질성은 우수하였다. 결론 : 본 논문에서 제안한 방법은 임상에서 MRI자장의 세기가 커질수록 RF코일 내부의 RF B1 균질성이 현저히 떨어지는 문제점이 있는데 이를 개선하는데 적용 할 수 있다고 사료된다.

  • PDF