• Title/Summary/Keyword: coaxial cable sensor

Search Result 18, Processing Time 0.035 seconds

Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band (마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구)

  • Yang, Seung-Hwan;Kim, Dong-Seok;Kim, Ki-Bok;Kim, Jong-Heon;Kang, Jin-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • In this paper, a non-contact microwave technique was presented to detect the surface crack of the metals. An open-ended coaxial cable line was used as a sensor at 11 GHz, and the reflection coefficients were measured by scanning along the metal surface including artificial surface cracks. A parameter, the K value which was defined as the difference between maximum and minimum reflection coefficients, was measured and used to estimate the crack depth. A linear relationship between the K value and crack depth was found. This study showed that non-contact detection of the surface cracks of metals is possible using the open-ended coaxial line sensor at X-band.

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

Design of Wired and Wireless linkage Hybrid Sensor Network Model over CATV network (CATV망을 이용한 유무선 연동의 하이브리드 센서 네트워크 모델 설계)

  • Lee, Kyung-Sook;Kim, Hyun-Deok
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.67-73
    • /
    • 2012
  • In this paper, in order to overcome the disadvantage of wireless-based sensor network, a hybrid sensor network using wired and wireless linkage is proposed. Proposed a wired and wireless linkage hybrid sensor network can compensate the defect of poor transmission at the indoor wireless environment, and can be free from interference between a wireless LAN and Bluetooth of the same frequency bandwidth due to an attribute of low-loss transmission at the CATV network. Also, proposed a wired and wireless linkage hybrid sensor network make use of CATV network which is well-built infrastructure, is more efficient to design network, assure a stability and high reliability of the sensor network as providing a stability for an inaccuracy and a predictable transmission link for the existing wireless network.

Wireless links for global positioning system receivers

  • Casciati, Fabio;Wu, Lijun
    • Smart Structures and Systems
    • /
    • v.10 no.1
    • /
    • pp.1-14
    • /
    • 2012
  • Given an object, its positioning in the space is a main concern in structural monitoring and a required feedback in structural health monitoring, structural control and robotics. In addition, to make the sensor unit wireless is a crucial issue for advanced applications. This paper deals with the exploitation of wireless transmission technology to long-term monitoring GPS (Global Positioning System) receivers - like the Leica GMX 902 and the Leica GRX 1200-pro. These GPS receivers consist of five parts: antenna, receiver, user client computer, interface and power supply. The antenna is mounted on the object to be monitored and is connected with the receiver by a coaxial-cable through which the radio frequency signals are transmitted. The receiver unit acquires, tracks and demodulates the satellite signals and provides, through an interface which in this paper is made wireless, the resulting GPS raw data to the user client computer for being further processed by a suitable positioning algorithm. The power supply reaches the computer by a wired link, while the other modules rely on batteries re-charged by power harvesting devices. Two wireless transmission systems, the 24XStream and the CC1110, are applied to replace the cable transmission between the receiver and the user client computer which up to now was the only market offer. To verify the performance and the reliability of this wireless transmission system, some experiments are conducted. The results show a successful cable replacement.

Development of Automatic Shutdown and Recovery Device for Standby Power using Doppler Sensor (도플러 센서를 적용한 대기전력 자동 차단복구 장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.243-249
    • /
    • 2019
  • In this paper, we have developed a device to reduce the standby power consumption that is unnecessarily consumed in unused electrical appliances. The Doppler sensor is used to automatically power off and power off the outlet depending on whether or not a person is present near the outlet. The Doppler sensor uses a coaxial cable trap to design a transmitting antenna and emits a 10 GHz band RF signal and receives a reflected wave signal whose wavelength is reflected from the target object to the receiver to detect an object and recognize human approach. It automatically cuts off and restores standby power to prevent unnecessary power consumption, saving energy and developing a standby power automatic shutdown and recovery device that can prevent the risk of large fires caused by leakage current.

Distributions of the Magnetic Flux Density Near Down-Conductors Due to Various Impulse Currents (임펄스전류에 의한 인하도선 주위에서 자속밀도의 분포)

  • 이복희;장근철;이수봉;강성만;이승칠
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2004
  • This paper deals with the behaviors of magnetic flux density near down-conductors by lightning currents. The background on the principle of magnetic flux density measurements using the RL self-integrating magnetic field sensor was described. The magnetic flux density measuring device consisting of RL self-integrating magnetic field sensor and differential amplifier was designed and fabricated. The frequency bandwidth of the magnetic flux density measuring system ranges from 200 Hz to 300 KHz and the response sensitivity was 0.126 $\mu$T/㎷ The distributions of the magnetic flux density near down-conductors due to impulse currents with various rise times were analyzed as a parameter of the bonding conditions and materials of conductor and wiring conduits. The magnetic flux density due to impulse currents was inversely proportional to the distance between the down-conductor and measuring point. The amplitude of the magnetic flux density for PVC Pipe with down-conductor was 72 $\mu$T/㎷ at the distance of 1m and was higher than for steel conduits and coaxial cable. Finally the magnetic flux density is increased with increasing the di/dt it and oscillation frequency of lightning currents in this experimental ranges.

UHF-Sensor with coaxial cable balun for Diagnosis of Insulator (GIS 부분방전 측정용 동축형 밸런 부착 다이폴 UHF 내장형 센서)

  • Park, Eun-Jung;Cho, Jun-Ho;Kim, Kyung-Bong;Kim, Ki-Chai;Kim, Jung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1457-1458
    • /
    • 2007
  • 본 논문은 전기에너지의 안정적인 공급을 위한 가스절연개폐장치(Gas Insulated Switchgear; GIS)의 안정성과 신뢰성을 확립하기 위해 GIS 내부 결함에 의한 사고의 발생을 미리 진단하는 절연진단용 UHF 대역($0.5\;{\sim}\;1.5$ GHz) 동축형 밸런 부착 안테나를 제안하였다. 동축형 밸런이 부착된 안테나를 GIS에 장착하였을 때 반사계수의 주파수특성을 실험치와 비교 검토하였다.

  • PDF

GPR using optical electric field sensor (광전계 센서(optical electric field sensor)를 이용한 GPR)

  • Cho Seong-Jun;Tanaka Ryohey;Sato Motoyuki;Kim Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.215-220
    • /
    • 2005
  • In order to apply to land mine detection effectively, GPR using an optical electric field sensor as a receiver has been developed. The optical electric field sensor is very small and uses optical fiber instead of metallic coaxial cable. With the combination of these advantages and the bistatic radar system, it can be possible for an operator to measure quite flexible and safely. The sensor has been tested in stepped frequency radar system with frequency which consists of a vector network analyzer, a fixed double ridged horn antenna as transmitter. For considering effectiveness in real field, we applied impulse radar system, which consist of a digital oscilloscope and a impulse generator to produce the impulse. Detection of a PMN2 mine model was carried out by the impulse radar system at a sand pit. The PMN2 were detected clearly with sufficiently high resolution, the target contrast was almost the same while the scanning time decreased down to 1/100.

  • PDF