DOI QR코드

DOI QR Code

Wireless links for global positioning system receivers

  • Casciati, Fabio (Department of Structural Mechanics, University of Pavia) ;
  • Wu, Lijun (Department of Structural Mechanics, University of Pavia)
  • Received : 2011.12.15
  • Accepted : 2012.05.22
  • Published : 2012.07.25

Abstract

Given an object, its positioning in the space is a main concern in structural monitoring and a required feedback in structural health monitoring, structural control and robotics. In addition, to make the sensor unit wireless is a crucial issue for advanced applications. This paper deals with the exploitation of wireless transmission technology to long-term monitoring GPS (Global Positioning System) receivers - like the Leica GMX 902 and the Leica GRX 1200-pro. These GPS receivers consist of five parts: antenna, receiver, user client computer, interface and power supply. The antenna is mounted on the object to be monitored and is connected with the receiver by a coaxial-cable through which the radio frequency signals are transmitted. The receiver unit acquires, tracks and demodulates the satellite signals and provides, through an interface which in this paper is made wireless, the resulting GPS raw data to the user client computer for being further processed by a suitable positioning algorithm. The power supply reaches the computer by a wired link, while the other modules rely on batteries re-charged by power harvesting devices. Two wireless transmission systems, the 24XStream and the CC1110, are applied to replace the cable transmission between the receiver and the user client computer which up to now was the only market offer. To verify the performance and the reliability of this wireless transmission system, some experiments are conducted. The results show a successful cable replacement.

Keywords

References

  1. Casciati, F. and Rossi, R. (2007), "A power harvester for wireless sensing applications", Struct. Health Monit., 14(4), 649-659. https://doi.org/10.1002/stc.179
  2. Casciati, F. and Fuggini, C. (2009), "Engineering vibration monitoring by GPS: long duration records", Earthq. Eng. Eng. Vib., 8(3), 459-467. https://doi.org/10.1007/s11803-009-9058-8
  3. Casciati, F. and Fuggini, C. (2011), "Monitoring a steel building using GPS sensors", Smart Struct. Syst., 7(5), 349-364. https://doi.org/10.12989/sss.2011.7.5.349
  4. Casciati, F. and Wu, L.J. (2011), "The wireless issue in positioning systems", Proceedings of the Eurodyn, Louvain, Belgium.
  5. Casciati, S. Faravelli, L. and Chen, Z.C. (2009), "Design of a multi-channel real-time wireless connection system for analog cable replacement application", Proceedings of the 7th IWSHM, Stanford, CA USA, Sept. 9-11.
  6. Digi International (2008), "X-CTU configuration & test utility software.pdf", ftp://ftp1.digi.com/support/documentation/ 90001003_a.pdf.
  7. Lanza di Scalea, F., Piervincenzo, R., Stefano, C., Ivan, B. and Mahmood, F. (2006), "Laser/air-coupled hybrid non-contact system for defect detection in rail tracks: status of FRA prototype development at UC san diego", J. Transport. Res. B., 1943, 57-64. https://doi.org/10.3141/1943-08
  8. Leica Geosystems AG (2007), "Leica GMX902 GG streamlined GNSS monitoring for critical structures", http:// www.leica-geosystems.com/en/Downloads-Downloads-Search_74590.htm?q=gmx+902.
  9. Leica Geosystems AG (2008), "Leica GPS1200+ user manual, http://www.surveyequipment.com/PDFs/GPS1200_User_en.pdf.
  10. Leica Geosystems AG (2010), "Leica SpiderQC Brochure", http://www.leica geosystems.com/en/downloadsdownloads search_74590.htm?search=true&product=GNSS%20QC%20Software.
  11. Lynch, J.P. and Loh, K. (2006), "A summary review of wireless sensors and sensor networks for structural health monitoring", Shock Vib., 38(2), 91-128. https://doi.org/10.1177/0583102406061499
  12. Kijewski-Correa, T., Kareem, A. and Kochly, M. (2006), "Experimental verification and full-scale deployment of global positioning systems to monitor the dynamic response of tall buildings", J. Struct. Eng.- ASCE, 132(8), 1242-1253. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:8(1242)
  13. MaxStream, Inc. (2006), "XStream OEM RF Module - Product Manual v5.x00, http://ftp1.digi.com/support/ documentation/roductmanual_xstream_oem_rfmodule_v5.x00.pdf.
  14. Spencer Jr., B.F. and Yun, C.B. (2010), Wireless sensor advances and applications for civil infrastructure monitoring, NSEL Report No. 024, University of Illinois at Urbana-Champaign.
  15. Texas Instruments (2007), "CC1110fx.pdf", http://www.alldatasheet.com.

Cited by

  1. Synergy of monitoring and security vol.17, pp.5, 2016, https://doi.org/10.12989/sss.2016.17.5.743
  2. Energy efficiency strategy for a general real-time wireless sensor platform vol.14, pp.4, 2014, https://doi.org/10.12989/sss.2014.14.4.617
  3. Dynamic testing of a laboratory model via vision-based sensing vol.60, 2014, https://doi.org/10.1016/j.engstruct.2013.12.002
  4. Local positioning systems versus structural monitoring: a review vol.21, pp.9, 2014, https://doi.org/10.1002/stc.1643
  5. Collecting data from a sensor network in a single-board computer vol.628, 2015, https://doi.org/10.1088/1742-6596/628/1/012113
  6. Vision-Based Sensing in Dynamic Tests vol.569-570, pp.1662-9795, 2013, https://doi.org/10.4028/www.scientific.net/KEM.569-570.767
  7. Sensor placement on Canton Tower for health monitoring using asynchronous-climb monkey algorithm vol.21, pp.12, 2012, https://doi.org/10.1088/0964-1726/21/12/125023