• Title/Summary/Keyword: co-cure

Search Result 154, Processing Time 0.027 seconds

Mixed-Mode Fatigue Characteristics of Composite/Metal Interfaces (복합재료/금속 계면의 혼합모드 피로 특성)

  • Baek, Sang-Ho;Kim, Won-Seock;Jang, Chang-Jae;Lee, Jung-Ju
    • Composites Research
    • /
    • v.23 no.4
    • /
    • pp.21-27
    • /
    • 2010
  • In most engineering structures, fracture often takes place due to fatigue. Therefore, many studies about the effect of the various mode-mixities on fatigue characteristics have been performed. However, most of the former studies only address metal/metal interfaces or delamination of composite. In this study, the fatigue characteristics of composite/metal interfaces are investigated. The fatigue tests were performed using single leg bending(SLB)specimens that comprise composite and steel bonded to each other using co-cure bonding method. This paper focuses on fatigue characteristics depending on different mode ratios$(G_{II}/G_T$. The overall results obtained in this study show that the crack propagation rate increases with the mode II loading component.

A Study on the Strength and Failure Mode of Co-cured Composite Joints (동시경화법으로 제조된 복합재료 조인트의 강도 및 파괴모드 연구)

  • Choi, Jin-Ho;Lee, Dae-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.385-392
    • /
    • 1997
  • The joint design and manufacture of the composite structure have become an important research area because the structural efficiency of the composite structure is often determined by its joint not by its basic structure. The co-cured joint is an efficient joint technique because both curing and jointing for composite structures are achieved simultaneously. In this paper, the torque capacities of the co-cured tubular lap joint with and without knurling of the pyamid type were experimentally measure. From the experimental resuts, it was found that the excess resin played a role as an adhesive in the co-cured tubular lap joint whose steel adherends were not knurled. Also, it was found that the torque capacity of the co-cured joint was increased as the knurling size of the pyramid type on the surface of the steel adherend was increased.

The optimization of new alignment films in the TNLC for low image-sticking

  • Lee, Jong-Hyun;Yi, Jun-Sin;Jung, Hwan-Kyung;Lee, Seung-Guk;Nam, Hyo-Hak;Nam, Yoon-Joung;Choi, Sung-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.513-516
    • /
    • 2007
  • We introduce a new copolymer alignment film made by bridge-building structure. It is a better film to decrease the image-sticking level in LCD displays. It is noted that the image-sticking was decreased by preventing ion mixing between inter-layers through high hardness. We have investigated the electrical characteristics such as pretilt angle, Residual DC, VHR by changing cure temperature and process delay time conditions of the new alignment film. In this paper, we have investigated the solution for the deep-rooted image defect and incidentally got a contrast ratio improvement by high anchoring force and hardness elevation through the new copolymer alignment film.

  • PDF

The Changes of Vulcanization and Physico-Mechanical Properties of NR/BR Blend with the Content of Sulfur and Accelerator (황 및 가황 촉진제의 함량에 따른 NR/BR 블렌드의 가황과 물리적·기계적 특성의 변화)

  • Kim, Wan-Young;Lee, Dai-Soo;Kim, Youn-Sop;Kim, Hyung-Soon;Nah, Chang-Woon
    • Applied Chemistry for Engineering
    • /
    • v.2 no.4
    • /
    • pp.356-362
    • /
    • 1991
  • The physico-mechanical properties of NR/BR blend were measured, and the results were interpreted in terms of the crosslink density with cure system. The cure rate, maximum torque and crosslink density increase with the content and ratio of curative for cure system. Hardness, 300 % tensile modulus, rebound and wear resistance increase with crosslink density of the vulcanizate but heat build-up and tan $\delta$ at $60^{\circ}C$ decrease. It is expected that semi-EV(efficient vulcanization) cure system is appropriate for application in tire tread of truck/bus in which load bearing property is impotant.

  • PDF

The Effect of Mass Transfer on the Cure Properties of the Urea Resin Moulding Compounds Under the Drying Process (건조 공정 중 요소 수지 성형재료의 경화 특성에 대한 물질전달 효과)

  • Kim, Sang Yeul;Choi, Il Gon;Kim, Byoung Chul
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.681-686
    • /
    • 2002
  • In the industrial field, the theory of drying process is different from the practical application, and it is effective to reduce energy by recirculation of the heat of exhausting gas. But the study of this field may not be performed still. The cure properties of the urea resin moulding compounds was investigated according to drying temperature, drying time, recycle rate of exhausting gas and moulding temperature in the process of drying and moulding. We obtained the following results; water content of material decreases with increasing drying time and drying temperature, and the rate of drying also decreases with increasing recycle rate of exhausting gas. Specially, The cure fluidity of the urea resin moulding compounds decreases, with increasing drying temperature, recycle rate of exhausting gas and moulding temperature. And the correlation equations on water content and cure fluidity of the urea resin moulding material were obtained through a regression analysis of experimental data.

INFLUENCES OF CAMPHOROQUINONE ON THE PROPERTIES OF COMPOSITES (Camphoroquinone이 복합레진의 특성에 미치는 영향)

  • 탁흥수;박상진
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The purpose of this study was to examine the influences of camphoroquinone on the properties of five experimental composites. The contents of camphoroquinone were varied as 0.2%, 0.3%, 0.4%, 0.5%, and 0.6%, with silanized filler 75% and tertiary amine 0.2%. Five kinds of experimental composites were prepared, and diametral tensile strength, shear bond strength, depth of cure and yellowish discoloration were tested as a measurement. Specimen numbers of 10 were applied to all test items and experimental groups. Specimens for testing the diametral tensile strengths with internal diameter of 6mm in diameter and 3mm in height were filled with 5 experimental composites which were crushed with 1mm/min cross-head speed on Instron universal testing machine (Model No. 4467). Shear bond strength was measured on specimens attached to bovine teeth enamel etched with 37% phosphoric acid. Depth of cure was measured by the measurement of height of specimens which were removed the un-polymerized portion with acetone. Yellowness measurements were made by chromometer(Minolta Co. Japan) using L$^*$a$^*$b$^*$ values. ANOVA and Multiple range tests were used analyzed data with confidence level at 95%. The mean value of the shear bond strengths ranged from 31.03MPa to 39.49MPa. Following results were obtained ; 1. Diametral tensile strength was highest in experimental group 3, then was not affected by the contents of camphoroquinone ($r^2$=0.0422). 2. Composite resins containing 0.4% camphoroquinone showed the highest shear bond strength, but there was no statistical significance (p=0.3718). 3. Camphoroquinone reduces the depth of cure in the composite resins (p=0.0004, $r^2$=0.9483). 4. Camphoroquinone made the composites yellowish ($r^2$=0.9815). These results mean that increased content of camphoroquinone reduces the depth of cure, and that camphoroquinone make composites yellowish.

  • PDF

Anti-obesity Effects of Misaengtang in Rats Fed on a High-Fat Diet or Normal Diet (고지방 식이와 일반사료를 섭취한 랫드에서 미생탕의 항비만 효과)

  • Ryu, Jae-Myun;Lee, Tae-Hee;Seo, Im-Kwon;Lee, Seung-Ho;Chang, Young-Hun;Kim, Yun-Bae;Hwang, Seock-Yeon
    • Toxicological Research
    • /
    • v.22 no.4
    • /
    • pp.339-348
    • /
    • 2006
  • Misaengtang (MST), a formula of Korean herbal medicines, has been used as a weight-controlling recipe. We have investigated two experiment of body weight regulation by MST In rats. i) The anti-obesity effect of MTS on a high fat diet-induced obesity, male Sprague-Dawley rats were fed with a high-fat diet containing 30% in the absence or presence of MST (0.3, 1 or 3%) or a reference orlistat (0.05%) for 6 weeks. ii) weight-decrease effect of MST on normal diet, same animal were fed with a normal diet in the absence or presence of MST (3%) for 6 weeks. And the body weights, daily feed and water consumptions, organ weights, fat weights serum biochemistry were measured. In both experiments, MST and orlistat did not affect the body weight gain. But orlistat significantly increased the feed and water consumptions, leading to low-feed efficiency, and orlistat markedly reduced abdominal, paratesticular and perirenal fat weights, although increased the kidney weights. In MST, low dose (0.3%) of MST decreased the perirenal fat and increased the kidney weights in rats fed HFD, and MST 3% decreased the abdominal fat weights in rats fed normal diet. In addition, Orlistat caused changes in parameters of hepatotoxicity (AST and glucose), nephrotoxicity (BUN and B/C ratio) and lipid metabolism (HDL and triglycerides). In comparison, MST decreased AST, ALP and ALT, the hepatotoxicity markers, and somewhat improved the hepatic fatty degeneration. Taken together, it is suggested that MST does not exert anti-obesity activity as well as remarkably direct effects, but MST may be potentially benefit for dietary cure and exercise-cure of obesity.

Curing Kinetics of the No-Flow Underfill Encapsulant

  • Jung, Hye-Wook;Han, Sang-Gyun;Kim, Min-Young;Kim, Won-Ho
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.134-137
    • /
    • 2001
  • The cure kinetics of a cycloalipatic epoxy / anhydride / Co(II) system for a no-flow underfill encapsulant, has been studied by using a differential scanning calorimetry(DSC) under isothermal and dynamic conditions over the temperature range of $160^{\circ}C ~220^{\circ}C$. The kinetic analysis was carried out by fitting dynamic/isothermal heating experimental data to the kinetic expressions to determine the reaction parameters, such as order of reaction and reaction constants. Diffusion-controlled reaction has been observed as the cure conversion increases and successfully analyzed by incorporating the diffusion control term into the rate equation. The prediction of reaction rates by the model equation corresponded well to experimental data at all temperature.

  • PDF

Cure Characteristics, Mechanical Properties and Abrasion Resistance of Silica Filled Natural Rubber Vulcanizate

  • Lee, Hae Gil;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.50 no.3
    • /
    • pp.159-166
    • /
    • 2015
  • Silica which is used for reinforcing filler in tire industry is widely known as eco-friendly material exerting $CO_2$ reduction effect through decrease of rolling resistance and improvement of wet grip. Generally silica is classified as a highly polar filler because it contains a large number of silanol (Si-OH) group on its surface. And also silica gives a lower reinforcing effect than carbon black due to its poorer rubber-filler interaction. Therefore silica is treated with silane coupling agent or activator, then following the conventional rubber blend method, vulcanized sheets were prepared using a hot press, and cure characteristics, mechanical properties and abrasion resistance of the test specimens were investigated. It was found that with an increase in the silane coupling agent content the tensile strength, 300% modulus and abrasion resistance increased while Mooney viscosity decreased and crosslink density slightly increased with an increase of activator.

Analysis of IR lens mounting with elastomer (밀봉재를 이용한 적외선 렌즈 마운팅 분석)

  • 김연수;김현숙;최세철;김창우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.460-462
    • /
    • 2001
  • We have analyzed the characteristics of IR lens mounting with elastomer and applied the results to the mounting of a silicon lens with diameter 117 mm which is the objective of a thermal imaging system. The elastomer, the 577 primerless silicone adhesive (Dow Corning Co.) which is heat cure type, and the mount material, A16061 are used for our analysis. Theoretical analysis gives the result that the space between lens and mount is required to be more than 250 ${\mu}{\textrm}{m}$ under the operational temperature conditions of -40~+6$0^{\circ}C$.

  • PDF