• Title/Summary/Keyword: cleansing water

Search Result 65, Processing Time 0.03 seconds

A SCANNING ELECTRON MICROSCOPIC STUDY OF THE EFFICACY OF ROOT CANAL IRRIGATION (근관세척(根管洗滌)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.147-153
    • /
    • 1982
  • The purpose of this study is to observe the effect of cleansing action of irrigation solutions which are 3% hydrogen peroxide, 5% sodium hypochlorite and 15% EDTA solution on the root canal wall. After the root canal wall is enlarged with K-file in distilled water, the canal wall which is irrigated with each irrigant for 2 minutes, is compared with the. control group without using any irrigants. Each sample is dehydrated, and coated with 200-250${\AA}$ of gold, and observations are made with the use of scanning electron microscope. The results are as follows: 1. The canal walls irrigated with 3% hydrogen peroxide, 5% sodium hypochlorite and 15% EDTA solution are cleaner than the walls without using irrigants. 2. There are no significant difference of cleansing effect among 3% hydrogen peroxide, 5% sodium hypochlorite and 15% EDTA. 3. After using 3% hydrogen peroxide and 5% sodium hypochlorite solution, large debris are removed on root canal walls, but micro debris remain on the canal walls. 4. The root canal walls irrigated with 15% EDTA solution are decalcifed slightly and show clean surfaces.

  • PDF

Influence of Forest Management on the Facility of Cleansing Water Quality in Abies holophylla and Pinus koraiensis Watershed(III) -With a Special Reference to pH and Electrical Conductivity of Rainfall, Throughfall and Stemflow- (전나무림(林), 잣나무림(林) 유역(流域)에서 산림(山林)의 수질정화기능(水質淨化機能)에 미치는 산림시업(山林施業) 영향(影響)(III) -임외우(林外雨), 수관통과우(樹冠通過雨), 수간류(樹幹流)의 pH와 전기전도도(電氣傳導度)를 중심(中心)으로-)

  • Jeong, Yongho;Park, Jae Hyeon;Youn, Ho Joong;Kim, Kyong Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.223-231
    • /
    • 2000
  • This study aims to clarify the effect of forest management practices(thinning and pruning) on water quality to get the fundamental information on the facility of cleansing water quality after forest operation. Rainfall, throughfall and stemflow were sampled at the study sites which consist of Abies holophylla and Pinus koraiensis in Kwangnung Experimental Forest for 6 months from May 4, to November 1, 1999. Average tree height in the management sites increased by 0.5m more than that in the non-management sites in Abies holophylla and Pinus koraiensis, respectively. Increment of average D.B.H. at the management sites grew 3.5cm and 2.6cm more in Abies holophylla and Pinus koraiensis compared with that at non-management sites. Average pH of the total amount for the event in throughfall and stemflow was higher than that of throughfall and stemflow of the beginning of the event at the management and non-management sites. Average electrical conductivity of throughfall and stemflow at the beginning of the event was higher than that of the total amount for the event at management and non-management sites. Water qualities of throughfall and stemflow were buffered more by the management practice in both. The forest management may affect purification of water quality of throughfall and stemflow in Abies holophylla and Pinus koraiensis.

  • PDF

Data Cleansing Algorithm for reducing Outlier (데이터 오·결측 저감 정제 알고리즘)

  • Lee, Jongwon;Kim, Hosung;Hwang, Chulhyun;Kang, Inshik;Jung, Hoekyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.342-344
    • /
    • 2018
  • This paper shows the possibility to substitute statistical methods such as mean imputation, correlation coefficient analysis, graph correlation analysis for the proposed algorithm, and replace statistician for processing various abnormal data measured in the water treatment process with it. In addition, this study aims to model a data-filtering system based on a recent fractile pattern and a deep learning-based LSTM algorithm in order to improve the reliability and validation of the algorithm, using the open-sourced libraries such as KERAS, THEANO, TENSORFLOW, etc.

  • PDF

Cleansing effect of the alkaline ionized water on microorganisms of the denture surface (알칼리 이온수의 의치 미생물에 대한 세정효과에 관한 연구)

  • Kim, Young-Mi;Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.138-144
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the cleansing effect of recently developed alkaline ionized water, e-WASH, on microorganisms of the denture surface. Materials and methods: Removable partial and complete dentures were randomly assigned to the experimental group of 41 dentures, and the control group of 26. The denture was immersed in the e-WASH solution (experimental group), or tap water (control group) for 5 minutes. The plaque was collected from the denture surface before and after immersion, and smeared on the slide glass. Amount and motility of microorganisms were compared according to the morphology and strain of microorganisms, using the phase contrast microscope. Statistical analysis was accomplished with paired t-test and independent t-test at 95% confidence level (P<.05). Results: 1. The amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were decreased after denture cleansing with the alkaline ionized water, e-WASH (P<.05). But in the control group, only the amount of cocci showed a significant difference (P<.05), but no difference from the others. There were no differences in other analysis. 2. In the experimental group, the amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were smaller and more inactive compared to the control group (P<.05). Conclusion: These results indicated that the alkaline ionized water, e-WASH could effectively reduce the amount and motility of the experimented microorganisms on the denture surface, and that e-WASH could be recommended as an effective denture cleanser.

Development of Transparent Cleansing Water with Salicylic Acid and Capryloyl Salicylic Acid (살리실릭애씨드 및 카프릴로일살리실릭애씨드가 적용된 투명 클렌징 워터의 개발)

  • Yeo, Hye Lim;Park, Injeong;Jung, So Young;Lee, So Min;Kim, Hyung mook;Lee, Mi-Gi;Kwak, Byeong-Mun;Bin, Bum-Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.2
    • /
    • pp.87-95
    • /
    • 2022
  • This study is about the development of transparent cleansing water with one of the beta-hydroxy acids (BHA), salicylic acid, and capryloyl salicylic acid, which is one of the lipo-hydroxy acids (LHA). Transparent appearance was stabilized by increasing the solubility of lipophilic salicylic acid and capryloyl salicylic acid in water using ethanol, polyol, and sodium hydroxide, and supplementing suspension and deposition using a double micelle structure of two types of PEG surfactants. Cleansing water applied with this technology was developed, and makeup removing ability and skin texture improvement ability were confirmed using an optical camera and an image analyzer. This solubilization technology is proposed as a new approach of LHA, which has been difficult to apply due to its low solubility in water, and is expected to help in the development of new chemical peeling products.

Water Scrubbing of Carbon Dioxide for Improving Calorific Values of Biogass (수세정에 의한 바이오가스 중 이산화탄소의 제거 효율)

  • Shim, Jae-Hoon;Hong, Seong-Gu;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.598-603
    • /
    • 2005
  • Biogas produced from anaerobic digestion processes has about 60% of methane and about 40% of carbon dioxide. Raw biogas can be used in internal combustion engines either spark ignition or diesel engines. Since the gas has relatively low calorific values, engine power also is lower than rated power values. Modified engines or biogas-specific engines have been utilized in order to increase efficiency. Another option is gas cleansing for increasing its calorific values. A couple of European countries adopted this approach in using biogas for one of transportation fuels, such as $CO_2$ scrubbing with water or special solutions. This study reports the results of water scrubbing for reducing $CO_2$ concentration. In 2.5m-high PVC pipe accepting water, $CO_2$ reduction rates were investigated. When flow rate of $CO_2$ and air mixture was about 5 LPM, $CO_2$ concentration was decreased up to 70%. Higher calorific biogas through water scrubbing is expected to be applied to various commercial engines without costly modification.

  • PDF

Prediction of lightweight concrete strength by categorized regression, MLR and ANN

  • Tavakkol, S.;Alapour, F.;Kazemian, A.;Hasaninejad, A.;Ghanbari, A.;Ramezanianpour, A.A.
    • Computers and Concrete
    • /
    • v.12 no.2
    • /
    • pp.151-167
    • /
    • 2013
  • Prediction of concrete properties is an important issue for structural engineers and different methods are developed for this purpose. Most of these methods are based on experimental data and use measured data for parameter estimation. Three typical methods of output estimation are Categorized Linear Regression (CLR), Multiple Linear Regression (MLR) and Artificial Neural Networks (ANN). In this paper a statistical cleansing method based on CLR is introduced. Afterwards, MLR and ANN approaches are also employed to predict the compressive strength of structural lightweight aggregate concrete. The valid input domain is briefly discussed. Finally the results of three prediction methods are compared to determine the most efficient method. The results indicate that despite higher accuracy of ANN, there are some limitations for the method. These limitations include high sensitivity of method to its valid input domain and selection criteria for determining the most efficient network.

회전형 세정수 제어시스템의 성능향상에 관한 연구

  • 윤소남;안병규;류재섭;우민호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.97-97
    • /
    • 2004
  • 본 연구에서 대상으로 하는 회전형 세정수 제어시스템은 비데용으로 사용되는 것으로, 크게 스테핑 모터부와 스테핑 모터에 의해서 구동되는 회전형 셀렉터부로 나눌 수 있으며, 셀렉터부는 비데, 일반세정, 국부세정, 건조의 4가지의 기능을 수행하는 구조로 되어있다. Fig. 1에 보이는 구조에서 상부셀렉터(upper selector)는 하부셀렉터(base selector)와 내부 자석사이에 위치해 있으며, 스테핑 모터의 초기 설정된 입력펄수 수에 비례하여 회전운동을 하고 해당 분사지점에 위치하게 된다.(중략)

  • PDF

Effect of Untreated Water Flow Rate at Certain Temperature on the Discharge of Treated Water

  • Ullah, Muhammad Arshad;Aslam, Muhammad;Babar, Raheel
    • The Korean Journal of Food & Health Convergence
    • /
    • v.5 no.6
    • /
    • pp.5-9
    • /
    • 2019
  • Desalination requires large energy. This experiment deals to desalinate brackish water through solar panels. The discharge from desalination plants is almost entirely water, and .01 percent is salt. Desalination is a process that extracts minerals from saline water. Solar-powered desalination technologies can be used to treat non-traditional water sources to increase water supplies in rural, arid areas. Water scarceness is a rising dilemma for large regions of the world. Access to safe, fresh and pure clean drinking water is one of the most important and prime troubles in different parts of the world. Among many of water cleansing technologies solar desalination/distillation/purification is one of the most sustainable and striking method engaged to congregate the supply of clean and pure drinkable water in remote areas at a very sound cost. Six types of dripper having discharge 3 - 8 lh-1 were installed one by one and measured discharge and volume of clean water indicated that at 6 lh-1 untreated water discharge have maximum evaporation and volume of clean water was 19.2 lh-1 at same temperature and radiations. Now strategy was developed that when increased the temperature the intake discharge of untreated water must be increased and salt drained water two times more than treated water.

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.