DOI QR코드

DOI QR Code

Cleansing effect of the alkaline ionized water on microorganisms of the denture surface

알칼리 이온수의 의치 미생물에 대한 세정효과에 관한 연구

  • Kim, Young-Mi (Department of Oral Health, Graduate School of Public Health and Social Welfare) ;
  • Choi, Yu-Sung (Department of Prosthodontics & Institute of Dental Science, School of Dentistry, Dankook University) ;
  • Cho, In-Ho (Department of Prosthodontics & Institute of Dental Science, School of Dentistry, Dankook University)
  • 김영미 (단국대학교 보건복지대학원 구강보건학과) ;
  • 최유성 (단국대학교 치과대학 치과보철학교실 및 치의학 연구소) ;
  • 조인호 (단국대학교 치과대학 치과보철학교실 및 치의학 연구소)
  • Received : 2011.02.19
  • Accepted : 2011.03.21
  • Published : 2011.04.29

Abstract

Purpose: The purpose of this study was to evaluate the cleansing effect of recently developed alkaline ionized water, e-WASH, on microorganisms of the denture surface. Materials and methods: Removable partial and complete dentures were randomly assigned to the experimental group of 41 dentures, and the control group of 26. The denture was immersed in the e-WASH solution (experimental group), or tap water (control group) for 5 minutes. The plaque was collected from the denture surface before and after immersion, and smeared on the slide glass. Amount and motility of microorganisms were compared according to the morphology and strain of microorganisms, using the phase contrast microscope. Statistical analysis was accomplished with paired t-test and independent t-test at 95% confidence level (P<.05). Results: 1. The amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were decreased after denture cleansing with the alkaline ionized water, e-WASH (P<.05). But in the control group, only the amount of cocci showed a significant difference (P<.05), but no difference from the others. There were no differences in other analysis. 2. In the experimental group, the amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were smaller and more inactive compared to the control group (P<.05). Conclusion: These results indicated that the alkaline ionized water, e-WASH could effectively reduce the amount and motility of the experimented microorganisms on the denture surface, and that e-WASH could be recommended as an effective denture cleanser.

연구 목적: 본 연구는 최근 개발된 알칼리 이온수 e-WASH의 의치에 부착된 미생물 의치세정 효과에 대해 위상차현미경을 이용한 미생물 관찰법을 통하여 알아보고자 하였다. 연구 재료 및 방법: 실험군 41개, 대조군 26개의 의치를 무작위로 선정하여 실험군에서는 알칼리 이온수e-WASH로, 대조군에서는 수돗물에 5분간 침지 전, 후 의치 내면의 치면세균막을 채취하였다. 위상차현미경으로 구강미생물의 형태적, 종류별 양과 운동성에 대하여 세정 전, 후별 구강미생물의 상태를 관찰하였다. 결과: 1. 알칼리 이온수 e-WASH로 의치를 세정한 실험군에서는 세정 전보다 세정 후 구균의 양, 간균의 양, 간균의 운동성, 실사균의 양, 실사균의 운동성, 콤마/나선균의 양, 콤마/나선균의 운동성 등 모든 조사항목에서 감소하였다 (P<.05). 한편 대조군에서는 구균의 양은 감소하였으나 (P<.05), 다른 조사항목에서는 모두 세정 전, 후 간에 차이가 없었다. 2. 알칼리 이온수e-WASH로 의치를 세정한 실험군에서는 구균의 양, 간균의 양, 간균의 운동성, 실사균의 양, 실사균의 운동성, 콤마/나선균의 양, 콤마/나선균의 운동성 등 모든 조사항목에서 수돗물로 의치를 세정한 대조군보다 각 구강미생물의 양과 운동성이 적게 나타났다 (P<.05). 결론: 위의 결과를 통해 알칼리 이온수 e-WASH가 의치표면의 각종 미생물의 양과 운동성을 효과적으로 감소시키므로 의치세정제로 추천된다.

Keywords

References

  1. Budtz-Jorgensen E, Bertram U. Denture stomatitis. I. The etiology in relation to trauma and infection. Acta Odontol Scand 1970;28:71-92. https://doi.org/10.3109/00016357009033133
  2. Budtz-Jorgensen E, Bertram U. Denture stomatitis. II. The effect of antifungal and prosthetic treatment. Acta Odontol Scand 1970;28:283-304. https://doi.org/10.3109/00016357009032036
  3. Nikawa H, Hamada T, Yamashiro H, Kumagai H. A review of in vitro and in vivo methods to evaluate the efficacy of denture cleansers. Int J Prosthodont 1999;12:153-9.
  4. Polyzois GL. Denture cleansing habits. A survey. Aust Dent J 1983;28:171-3. https://doi.org/10.1111/j.1834-7819.1983.tb05275.x
  5. Kim MJ, Shin SW, Lee JY. In vitro study on the adherence and penetration of candida albicans into denture soft lining materials. J Korean Acad Prosthodont 2006;44:466-76.
  6. Dills SS, Olshan AM, Goldner S, Brogdon C. Comparison of the antimicrobial capability of an abrasive paste and chemical-soak denture cleaners. J Prosthet Dent 1988;60:467-70. https://doi.org/10.1016/0022-3913(88)90250-8
  7. Budtz-Jorgensen E, Kelstrup J. Enzymes as denture cleansers. Scand J Dent Res 1977;85:209-15.
  8. Ryoo KK, Kang BD, Sumita O. Electrolyzed water as an alternative for environmentally benign semiconductor cleaning. J Mater Res 2002;17:1293-304.
  9. Chang YS, Jung MA, Shin SC. Evaluation of motility and distribution of oral micro-flora in Koreans using the phase contrast microscope. Int J Clin Prevent Dent 2008;4:28-39.
  10. Lee WH, Bok HJ, Kim HJ, Ahn SH. Correlation coefficient between the age and the amount/motile of the oral microorganisms examined by phase contrast microscope. Int J Clin Prev Dent 2009;5:7-13.
  11. Lee YJ. Oral microorganism in saliva according to ages, observed through phase contrast microscope. Int J Clin Prev Dent 2009;5:23-30.
  12. Ku HM, Lee JH, Woo SH, Cho JW. Amounts of gingival crevicular fluid according to age and the relations with oral micro-organism. Int J Clin Prev Dent 2009;5:93-101.
  13. Makila E, Hopsu-Havu VK. Mycotic growth and soft denture lining materials. Acta Odontol Scand 1977;35:197-205. https://doi.org/10.3109/00016357709004655
  14. Gusberti FA, Gada TG, Lang NP, Geering AH. Cultivable microflora of plaque from full denture bases and adjacent palatal mucosa. J Biol Buccale 1985;13:227-36.
  15. Paranhos HF, Silva-Lovato CH, de Souza RF, Cruz PC, de Freitas-Pontes KM, Watanabe E, Ito IY. Effect of three methods for cleaning dentures on biofilms formed in vitro on acrylic resin. J Prosthodont 2009;18:427-31. https://doi.org/10.1111/j.1532-849X.2009.00450.x
  16. de Freitas Fernandes FS, Pereira-Cenci T, da Silva WJ, Filho AP, Straioto FG, Del Bel Cury AA. Efficacy of denture cleansers on Candida spp. Biofilm formed on polyamide and polymethyl methacrylate resins. J Prosthet Dent 2011;105:51-8. https://doi.org/10.1016/S0022-3913(10)60192-8
  17. Glass RT, Bullard JW, Conrad RS, Blewett EL. Evaluation of the sanitization effectiveness of a denture-cleaning product on dentures contaminated with known microbial flora. An in vitro study. Quintessence Int 2004;35:194-9.
  18. Chun SS, Chung CH, Lee ZH. Determination of antifungal ability of denture cleansing agents to Candida albicans. J Korean Acad Prosthodont 1993;31:28-38.
  19. Davenport JC, Wilson HJ, Spence D. The compatibility of soft lining materials and denture cleansers. Br Dent J 1986;161:13-7. https://doi.org/10.1038/sj.bdj.4805880
  20. Harrison A, Basker RM, Smith IS. The compatibility of temporary soft materials with immersion denture cleansers. Int J Prosthodont 1989;2:254-8.
  21. Kim KS, Jeong HY, Kim YL, Cho HW. The effect of denture cleansers on the bond strength and the surface hardness of reline resin to denture base resin. J Korean Acad Prosthodont 2003;41:493-502.
  22. Jang BS, Kim CW, Kim YS. The effect of denture cleansers on soft lining materials. J Korean Acad Prosthodont 1993;31:219-35.
  23. Budtz-Jorgensen E. Materials and methods for cleaning dentures. J Prosthet Dent 1979;42:619-23. https://doi.org/10.1016/0022-3913(79)90190-2
  24. Klinger SM, Lord JL. Effect of common agents on intermediary temporary soft reline materials. J Prosthet Dent 1973;30:749-55. https://doi.org/10.1016/0022-3913(73)90226-6
  25. Abadias M, Usall J, Oliveira M, Alegre I, Vinas I. Efficacy of neutral electrolyzed water (NEW) for reducing microbial contamination on minimally-processed vegetables. Int J Food Microbiol 2008;123:151-8. https://doi.org/10.1016/j.ijfoodmicro.2007.12.008
  26. Sharma RR, Demirci A. Treatment of Escherichia coli O157:H7 inoculated alfalfa seeds and sprouts with electrolyzed oxidizing water. Int J Food Microbiol 2003;86:231-7. https://doi.org/10.1016/S0168-1605(02)00549-4
  27. Kim JJ, Lee MY. Bactericidal effects of anodic electrolyzed water on the selected gram-negative and gram-positive bacteria. J Environment Sci 2007;16:1295-300.
  28. Jeong JW, Kim JH, Kim BS, Jeong SW. Characteristics of electrolyzed water manufactured from various electrolytic diaphragm and electrolyte. Korean J Food Preserv 2003;10:99-105.
  29. Kwon NH, Kim SH, Kim JY, Lim JY, Kim JM, Jung WK, Park GT, Bae WK, Noh KM, Choi JW, Park YH. Antimicrobial activity of GC-100X against major food-borne pathogens and detaching effects of it against Escherichia coli O157:H7 on the surface of tomatoes. J Food Hyg Safety Abstracts 2002:160-1.
  30. Park HL, Kim YK, Ryoo KK, Lee YB, Lee JK, Lee MY. Studies on the antibacterial effects of electrolyzed reduced water. J Korean Acad Industrial Soc 2005;6:215-21.
  31. Jin YG, Kim TW, Ding T, Oh DH. Effect of electrolyzed water and citric acid on quality enhancement and microbial inhibition in head lettuce. Korean J Food Sci Technol 2009;41:578-86.
  32. Ryoo KK, Lee YB, Lee JK, Lee MY. Permeability and dissolvability of cathodic electrolyzed water for electrophoretic gel and green tea components. J Korean Acad Indus Soc 2005;6:87-93.

Cited by

  1. Antifungal effects of hydrogen water on the growth of Candida albicans vol.43, pp.4, 2011, https://doi.org/10.11149/jkaoh.2019.43.4.173