• Title/Summary/Keyword: cleaning-in-place

Search Result 64, Processing Time 0.028 seconds

중요민속자료 제112호 장흥임씨 수의류의 보존처리

  • An, Hui-Gyun;Han, Seong-Hui;Jeong, Hui-Jin;Kim, Gi-Seop
    • 보존과학연구
    • /
    • s.6
    • /
    • pp.96-110
    • /
    • 1985
  • This report is briefly thied to introduce the kinds of clothes for the body of deceased and special features of remains in the era of the middle of Yidynasty found in Changheung IM's tomb, and some remarks related to the conservation treatment for shrouds as well. The contents of this report are summed up as follows:1. Included with the clothes of dead body of IM's clan were 2 pcs. Of woman's jacket, 2 pcs. of underpants, 1pcs. of single layered overcoat twithout cotton, 1pcs.of women's overcoat with a single layered thin cotton inside, women's socks, cushoned mattress, straw shoes and other hemp fabrics etc. By the observation of these remains, it is considered that they dressed the deceased with new cloth taken from the unsuals not prepared specially and stored beforehand for such as occasion as does it nowadays.2. As to the conservation treatment, the materials were comparatively good and so they employed general tank washing method with special neutrality liquid soap(made by Lab, of Household Products, Pacific R & D Center) for cleaning imbrued matrials on the clothes. After cleaning and drying naturally at a shade place, remains put into apaulowania tree box were fumigated by mixed gas (M. B. + E. O.) for prevention of damages from fungi and insects.3. Desirable environment control for scientific conservation of such kinds of cellulose textiles is to be illuminated at below 50Lux, temperature 16-18℃, relative humidity 45-60%($\pm$4%) and removed the dust. For the prevention of the damaging fungi and insects, it is desirable to fumigate by mixed gas (M.B.+E.O.) once a year.

  • PDF

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

A Study of Housing Environment Problems through the Daily newspapers ( II ) -Centering around a excretion and fixing process of lavatory- (일간지를 통해 본 주거환경문제의 연구 ( II ) - 분뇨에서 변소의 정착과정을 중심으로 -)

  • 신경주
    • Journal of the Korean housing association
    • /
    • v.3 no.2
    • /
    • pp.89-99
    • /
    • 1992
  • We discussed the change of housing environmental problems from the early 1900s to the present in Study(I). This study(II) which secendly research of study(I) analyzed the fixing precess of a lavatory centering around a excretion which was a serious housing environmental problem in 1920 to 1940. The documentary research method was used for this study. Articles of content analysis(N=185) were published in 1920 to 1990 which were The Deng-A daily news article about a excretion and a lavatory. The main content of this study was examined the change, such as the number of whole article, the column number of article by time series. and the content of article by subject. 1. The number of whole article by time series was collected mainly in1920s-1930s. In 1940s-1960s, one-two column of article was appeared generally and three-four, five column of article was appeared in 1970-1980. 2. Contents of article was divided into two classes, excretion and lavatory. Contents of excretion was 1) a use of fertilizer 2) the method of transportation 3) a cost of gathering 4) a place of disposal 5) the problem of cleaning. Contents of lavatory was 1) a public lavatory 2) a flush toilet 3) a sanitary conditions 3. 1) A use of fertilizer was concentrated in 1920s-1930s, and problems of it was solved more or less by change of management method. Transportation of excretion developed such as \ulcornerGue\ulcorner->a coach of tank style->underground transportation->a dung car of absorption style. Disposal place of excretion was a cause of dissatisfaction in 1920s and it is serious problem Today. A duty of excretion gathering was transfered to a private worker in 1978. The accunulation problem of excretion was continued until 1940s-1950s. The management law of waste matters was proclaimed in 1986. 2) A public lavatory was planned in 1924 for the first time, and it is insufficient in these days, A settlement of public lavatory in building which has upward of 20pyung became obligation in 1973. The problem of water contamination which by poor septic tank was happened in 1970s-1980s.

  • PDF

A Follow up Study on the Mercury Concentration in Air and in Urine of Workers after Implementing Controls of Work Environment in Mercury Vapor Exposed Industry (모 수은폭로 사업장의 작업환경개선에 의한 근로자의 요중 수은 및 공기중 수은 농도의 추적조사 연구)

  • Bang, Shin Ho;Kim, Kwang Jong;Park, Jong Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.198-207
    • /
    • 1994
  • In order to evaluate the effectiveness of environmental intervention of work place, metal mercury concentration in air and in urine of the total 43 workers for 3years from December 1991 to October 1993 in a fluorescent lamp manufacturing industry exposed to mercury, was measured before and after implementation of controls such as establishing exhaust ventilation at the department of exhaustion, coating the floor of work place with epostane, cleaning of the floor, improved housekeeping, and etc. The results were as follows. 1. Before the intervention(December 1991) 39.0% exceeded metal mercury Threshold Limit Value(TLV, $0.05mg/m^3$). After the intervention(October 1993) 10.0% exceeded TLV and geometric mean of mercury in air was $0.1mg/m^3$, and showed effectiveness rate of intervention to be 74.4% 2. After the intervention, geometric means of mercury concentrations in air were 0.013, $0.019mg/m^3$ and showed effectiveness rate of intervention to be 76.6%, 65.5% in A factory(right tube lamp)and at exhaustion department, respectively, A follow up survey fround statistically significant reductions in mercury concetration in air three years later. 3. Mercury concentration in urine of 11 workers(29.7%) exceeded warning level of $100{\mu}l/l$ before the intervention. After the intervention, of 3workers(8.8%) exceeded warning level and geometric mean of mercury concentration($26.5{\mu}l/l$) in urine was 2.4 times than that of before the intervention. Geometric means of mercury concentrations in urine of workers at exhaustion department, at sealing and aging department were 44.0, $77.7{\mu}l/l$, respectively and they decreased 2.3, 3.2 times than that of before the intervention.

  • PDF

A Study on Etching of $UO_2$, Co, and Mo Surface with R.F. Plasma Using $CF_4\;and\;O_2$

  • Kim Yong-Soo;Seo Yong-Dae
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.507-514
    • /
    • 2003
  • Recently dry decontamination/surface-cleaning technology using plasma etching has been focused in the nuclear industry. In this study, the applicability of this new dry processing technique are experimentally investigated by examining the etching reaction of $UO_2$, Co, and Mo in r.f. plasma with the etchant gas of $CF_4/O_2$ mixture. $UO_2$ is chosen as a representing material for uranium and TRU (TRans-Uranic) compounds while metallic Co and Mo are selected because they are the principal contaminants in the used metallic nuclear components such as valves and pipes made of stainless steel or inconel. Results show that in all cases maximum etching rate is achieved when the mole fraction of $UO_2\;in\;CF_4/O_2$ mixture gas is $20\%$, regardless of temperature and r.f. power. In case of $UO_2$, the highest etching reaction rate is greater than 1000 monolayers/min. at $370^{\circ}C$ under 150 W r.f. power which is equivalent to $0.4{\mu}m/min$. As for Co, etching reaction begins to take place significantly when the temperature exceeds $350^{\circ}C$. Maximum etching rate achieved at $380^{\circ}C\;is\;0.06{\mu}m/min$. Mo etching reaction takes place vigorously even at relatively low temperature and the reaction rate increases drastically with increasing temperature. Highest etching rate at $380^{\circ}C\;is\;1.9{\mu}m/min$. According to OES (Optical Emission Spectroscopy) and AES (Auger Electron Spectroscopy) analysis, primary reaction seems to be a fluorination reaction, but carbonyl compound formation reaction may assist the dominant reaction, especially in case of Co and Mo. Through this basic study, the feasibility and the applicability of plasma decontamination technique are demonstrated.

Empirical Modeling of Fouling Rate of Milk Pasteurization Process : A case study

  • Budiati, Titik;Wahyono, Nanang Dwi;Hefni, Muh.
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Fouling in heat exchanger becomes a major problem of dairy industry and it increases the production cost. These are lost productivity, additional energy, additional equipment, chemical, manpower, and environmental impact. Fouling also introduces the risk of food safety due to the improper heating temperature which allow the survival of pathogenic bacteria in milk, introducing biofilm formation of pathogenic bacteria in equipments and spreading the pathogenic bacteria to milk. The aim of this study is to determine the fouling rate during pasteurization process in heat exchanger of pasteurized milk produced by Village Cooperative Society (KUD) "X" in Malang, East Java Indonesia by using empirical modeling. The fouling rate is found as $0.3945^{\circ}C/h$ with the heating process time ranged from 0 to 2 hours and temperature difference (hot water inlet temperature and milk outlet temperature) ranged from 0.654 to $1.636^{\circ}C$. The fouling rate depends on type and characteristics of heat exchangers, time and temperature of process, milk type, age of milk, seasonal variations, the presence of microorganism and more. This results will be used to plan Cleaning In Place (CIP) and to design the control system of pasteurization process in order to maintain the milk outlet temperature as standard of pasteurization.

Analysis on Residents Consciousness about Management of the Exterior Space in Apt. Complex (대단위 아파트 단지의 조경공간 관리에 대한 주민의식 분석 - 대구시 지산지구 아파트단지를 대상으로 -)

  • Lee, Kee Cheol;Lee, Hyun Taek;Kim, Dong Pil;Lee, Jeong
    • Current Research on Agriculture and Life Sciences
    • /
    • v.12
    • /
    • pp.35-49
    • /
    • 1994
  • The Purpose of this study was to establish the belter residential environment in Apt. complex. In this study, the management consciousness of exterior space and the degree of satisfaction were investigated and analyzed on the GI-SAN Apt. complex in Taegu city. The data were obtained through the questionnaire survey about the exterior space of Apt. complex and analyzed by the SPSS/PC. The results of this analysis are as follow; The result of the image analysis were the cleanness factor and the arrangement factor, which have great influenced in residents image of exterior space. The dissatisfaction source of the management conditions were owing to the lake of management techniques and the discord of residents. The subject of management in the residents consciousness was the management office. In additionally, the management form by the residents were highly showed the cleaning and weeding. The main issues of their dissatisfaction about the exterior space was the lake of size, quantity of plants and rest space. The place of the most demand on management was investigated the children playground which was regarded to be the most damaged.

  • PDF

A Study on the Bacterial Contamination and Antimicrobial Resistance in Expressed Human Milk (수집모유의 미생물오염과 항균제 내성에 관한 연구)

  • Hwang, Kyeong-Mi;Kang, Young-Sil
    • Journal of Korean Biological Nursing Science
    • /
    • v.10 no.2
    • /
    • pp.131-140
    • /
    • 2008
  • Purpose: This study is about safety of the expressed human milk by investigating its bacterial contamination and antibiotic resistance of the microbes in the expressed milk. Methods: The data are collected from the 156 mothers and their newborn infants in NICU of U University Hospital from January 2004 to September 2005. Results: 1) The expressed human milk was contaminated by Staphylococcus epidermidis for 66.7%, Two mixed bacterial strain for 11.5%, Acinetobacter species for 8.0%, Klebsiella species for 4.6%, Staphylococcus aureus for 4.6%. 2) The microbes in the human milk had high resistance to the Antimicrobial agents: 77.5% for Penicillin-G, 66.6% for Oxacillin, and 63.7% for Cephalothin. 3) The distribution of microbes showed a significant depending on the place of the milk expression (p=.020). In particular, mixed bacterial strain was found more in the milks expressed at home than the milk expressed at the hospital. Conclusion: This study shows the importance of systematic education of feeding process in expressed milk: poor management of a breast pump, inadequate hand washing and imperfect breast cleaning explain the reasons of contamination 156 cases.

  • PDF

Rainwater for Water Scarcity Management: An Experience of Woldia University (Ethiopia)

  • ANDAVAR, Venkatesh;ALI, Bayad Jamal;ALI, Sazan Ahmed
    • Asian Journal of Business Environment
    • /
    • v.10 no.4
    • /
    • pp.29-34
    • /
    • 2020
  • Purpose: Town of Woldia, a semi-arid region in the Northern Wollo region of Ethiopia, faces water supply shortage in general, though the town possesses a running stream of clean water throughout the year. This study is aimed at analyzing the possibility of using rainwater for water scarcity and non-potable water needs of the Woldia University. A careful study and analysis have been made to assess the feasibility of using rainwater in place of the tap water supply. Research design and methodology: This study was done inside the main campus of Woldia University located in Woldia town. The runoff water from the roof of buildings was studied, by the time of rainfall in the town. Also, the budget needed for implementing a rainwater harvesting system was calculated. Results: The findings of the study clearly indicates that the requirements of the water to use for flushing, cleaning, and washing toilets in the administrative buildings and classrooms can be satisfied by using rainwater as an alternative to tap water. Conclusion: Based on the results the study finds it is benefitable for the Woldia University to install the rainwater harvesting system at the earliest to solve the water problems prevailing in the current situation.

Change in Reflection Performance of Highway Lanes Through Lane Washing and Sweeping (차선세척과 청소를 통한 고속도로 차선의 반사성능 변화)

  • Lee, Seong-Sik;Oh, Heung-Un
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.117-126
    • /
    • 2018
  • PURPOSES : The purpose of this paper is to analyze the change in lane reflection performance through lane washing and sweeping on highway lanes. METHODS : This paper compared and analyzed the changes in lane reflection performance before and after lane washing and sweeping. The research method was as follows. First, we selected four research sites on the Gyeong-bu Highway. Second, the parameters affecting lane reflection performance are classified into luminance, brightness, and number of glass beads. Third, the change in reflection performance was measured after washing /sweeping at the same place after studying 60m of the unwashed/unswept area. Fourth, the measurement results were compared and analyzed before and after lane washing/sweeping. RESULTS : The results of this study are as follows. First, lane washing improved the luminance and brightness by 4.2~21.4% and 1.4~5.1%, respectively, and reduced the number of glass beads per wash by 0.2~1.2%. Second, lane sweeping improved the luminance and brightness by 2.3~8.5% and 0.8~2.3%, respectively, and reduced the number of glass beads per sweep by 0.8~4.9%. CONCLUSIONS : By comparing the results of lane washing and sweeping, it was found that compared to lane sweeping, lane washing improved the luminance and fewer glass beads were dropped.