• Title/Summary/Keyword: cleaning methods

Search Result 485, Processing Time 0.03 seconds

Dyeing Properties of Acetate/Functional Polyester Composite Yarn in Different Yarn Twisting Processes (연사방법에 따른 아세테이트/기능성 폴리에스터 복합사의 염색성에 관한 연구)

  • Kim, So-Jin;Jeon, Dong-Won;Park, Young-Hwan
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.2 s.150
    • /
    • pp.255-265
    • /
    • 2006
  • The purpose of this study was to examine the dyeing properties of four kinds of composite yams that were twisted in different processes. The composite yarns consist of acetate and functional polyester in ratio of 70 : 30. The composite yams were dyed at 100$^{circ}C$ and 125$^{circ}C$ using three types of dyes, disperse dyes for acetate fiber, PET fiber and PET-acetate blended fiber, in the three primary colors. The exhaustion($\%$) and K/S value were observed for each case. Also the effects of four different twisting processes to dyeing properties and physical properties were examined. Regardless of twisting methods, the composite yarns that were dyed at 125$^{circ}C$ had higher exhaustion($\%$) than those were dyed at 100$^{circ}C$ with all three types of dyes; However, tendency of the K/S value after reduction cleaning process was measured at 100$^{circ}C$ and the value measured 125$^{circ}C$ had a great difference with disperse dyes for acetate and dyes for PET. The difference of the K/S values of composite yarns, when dyed at 100$^{circ}C$ and 125$^{circ}C$ with disperse dyes for PET-acetate blended fiber, was almost negligible. According to twisting methods K/S values were in the following order: AP1 > AP3 > AP4> AP2. This means that AP1, treated at 220$^{circ}C$, had the highest K/S value and K/S value becomes higher as the yam is higher twisted and becomes lower as lower twisted. On the other hand, the dry shrinkage and wet shrinkage showed low shrinkage rate when the twist was high and steam setting temperature was high.

Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement (직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구)

  • Yeo, Jin-Hee;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

Dyeing Properties and Storage Stability of Leaf Powder Prepared from Dyer's Knotweed(II) - by Hot Air and Room Temperature Drying Methods - (생쪽잎분말의 염색성 및 저장성(II) - 열풍 및 상온건조방법 -)

  • Shin, Youn-Sook;Son, Kyung-Hee;Yoo, Dong-II
    • Textile Coloration and Finishing
    • /
    • v.21 no.4
    • /
    • pp.23-32
    • /
    • 2009
  • The objective of this study is to investigate the efficacy of leaf powder colorants as substitutes for traditional indigo dyeing. Leaf powder colorants were prepared by hot air($50^{\circ}C$) and room temperanrre($25^{\circ}C$) drying methods from fresh leaves. The presence of indigo in the leaf powder colorants was confirmed by UV/Visible absorption spectra. All the powder colorants showed broad absorption at 602 nm as same as synthetic indigo. Dyeing was done by reduction method with sodium hydrosulfite and sodium hydroxide. Leaf powder colorants produced blue color on silk fabrics, showing similar color to the one dyed traditionally with fresh juice extract. The powder colorants prepared at room temperature drying were more stable for long term storage than that prepared by hot air drying. Thus, the powder colorants prepared by room temperature drying was reduced and dyed in one-step process without sodium hydroxide in the dyebath for further investigate dyeing properties. K/S value of the fabric dyed without sodium hydroxide was much higher than one dyed with sodium hydroxide. Regardless of the addition of sodium hydroxide, rubbing fastness was fairly good showing above 4 rating. Fastness to dry cleaning and light of the fabrics dyed without sodium hydroxide were mote higher than that dyed in alkaline condition.

A Study on Care Labels for Wearing and Handling Behaviors of Jeans

  • Uh, Mi-Kyung;Park, Myung-Ja
    • The International Journal of Costume Culture
    • /
    • v.9 no.2
    • /
    • pp.133-148
    • /
    • 2006
  • This research endeavors to provide correct handling methods of jeans through a study on care labels for wearing and handling behaviors of female university students in their twenties. The conclusion of the research is as follows: The study indicates that coeds own more than seven jeans and wear them three or four times a week on the average. The research showed that washing jeans once weekly is the highest. It showed that the jeans are mainly laundered with water and also with water and dry cleaning together. The students responded that they dry cleaned the pants several times and then water wash them after buying the pants in order to prevent change in colors and shapes of the pants. Content of labels should be improved because most female students indicated the importance of the care labels. The reliability and understanding of the labels were surveyed to be lacking. The survey indicated that the percentage of checking the sizes was the highest when the students bought the jeans. Furthermore, the label "handle with care" turned out to be examined more frequently than the indication, "textile materials breakdown" when they took care of the clothes including laundering or ironing. Moreover, the students experienced extensive color change after water washing and other accidents when taking care of their clothes. Their attitudes were surveyed to be very passive on handling the problems after washing or handling jeans. Therefore, the study concluded that the labeling methods should be improved especially in regard to the validity verification of the label contents and also the manufacturers should make concerted efforts to improve and enhance the consumer's rights and interests for effectiveness and accuracy of the descriptive labels.

  • PDF

The SPM Study on the Change of Titanium Surface Roughness following Airpowder Abrasive and Application Time of Citric Acid (공기-분말 연마와 구연산의 적용시간에 따른 임프란트 표면 거칠기의 변화에 관한 주사탐침현미경적 연구)

  • Park, Min-Seo;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.4
    • /
    • pp.821-836
    • /
    • 2000
  • The Peri-implantitis causes inflammation of periodontal tissue and bone loss. It contaminates surface of implants. Therefore, guided bone regeneration has been used for the treatment of this disease. For the reosseointegration of the exposed surface, various mechanical and chemical methods have been used for cleaning and detoxication of implant surface. Among these methods, air-powder abrasive and oversaturated citrate are known to be most effective. However, these treatments may deform implant surface. In this research, changes of surface roughness they were examined. 10 experimental machined titanium cylinder models were fabricated to be used for control groups. Each of them was air powder abraded for 1 minute and they were named group 1. And then, group 1 were burnished with cotton pellets soaked with citrate for 30 seconds(Group 2), 1 minute(Group 3), 3 minutes(Group 4), and 5 minutes(Group 5) burnishing were applied for grouping respectively. Each group were examined with SPM, and their surface roughness were measured and analyzed. 1. Surface roughness of titanium decreased when it was air-powder abraded for 1 minute. It was statistically significant. 2. When Air-powder abraded titanium were treated with citrate for 3 minutes, Their surface roughness was the lowest. Titanium treated for 1 minute was the second lowest and 30 seconds was the third and titanium burnished for 5 minutes was the highest. 3. Surface roughness of titanium which was treated with citrate was decreased till 3 minutes, which was statistically significant. There was no statistical significance from 30 seconds to 1 minute and from 1 minute to 3 minutes, and there was statistical significance from 30 seconds to 3 minutes. 4. Oxide layer was formed when titanium is exposed to air, and it was removed when air-powder abraded. It was made when treated with citrate. It is thought that citrate treatment is necessary after the air-powder abrasion, and 1 minute is clinically and qualitatively adequate for burnishing time of citrate.

  • PDF

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

Smear layer removal by passive ultrasonic irrigation and 2 new mechanical methods for activation of the chelating solution

  • Ricardo Machado ;Isadora da Silva;Daniel Comparin;Bianca Araujo Marques de Mattos ;Luiz Romulo Alberton ;Ulisses Xavier da Silva Neto
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.11.1-11.11
    • /
    • 2021
  • Objectives: The aim of this study was to compare smear layer removal by conventional application (CA), passive ultrasonic irrigation (PUI), EasyClean (EC), and XP-Endo Finisher (XPF), using 17% ethylenediaminetetraacetic acid (EDTA) after chemomechanical preparation, as evaluated with scanning electron microscopy (SEM). Materials and Methods: Forty-five single-rooted human mandibular premolars were selected for this study. After chemomechanical preparation, the teeth were randomly divided into 5 groups according to the protocol for smear layer removal, as follows: G1 (control): CA of distilled water; G2 (CA): CA of 17% EDTA; G3 (PUI): 17% EDTA activated by PUI; G4 (EC): 17% EDTA activated by EC; and G5 (XPF): 17% EDTA activated by XPF. SEM images (×1,000) were obtained from each root third and scored by 3 examiners. Data were evaluated using the Kruskal-Wallis and Dunn tests (p < 0.05). Results: In the apical third, there were no statistically significant differences among the groups (p > 0.05). In the cervical and middle thirds, the experimental groups performed better than the control group (p < 0.05); however, G2 presented better results than G3, G4, and G5 (p < 0.05), which showed no differences among one another (p > 0.05). Conclusions: No irrigation method was able to completely remove the smear layer, especially in the apical third. Using CA for the chelating solution performed better than any form of activation.

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

The Effects of Professional Tooth Cleaning and Plaque Control Instruction on Reduction of Peri-implantitis (전문가치면세정술과 세균막관리교육의 임플란트 주위염 감소 효과)

  • Park, Kyung-Hwa;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.163-170
    • /
    • 2012
  • The purpose of this study was determine the effects of professional tooth cleaning and plaque control instruction(PT & PCI) on reduction of peri-implantitis. A total 80 implant patients were investigated using O'Leary plague index(PI), L${\ddot{o}}$e & Silness gingival index(GI), implant bone loss(BL). While the PT & PCI was conducted by using 'Watanabe method' after scaling for the experimental group, the engine polishing and a plaque control instruction was operated by rolling method after scaling for the control group. The collected data were analyzed with t-test, ANOVA, paired t-test and stepwise multiple regression. PI and GI of the experimental group significantly decreased than the control group(p<0.05). BL, also tended to decreased in the experimental group than the control group(p=0.155). Multiple regression analysis, the factors that was highly correlated with PT & PCI on the PI and GI. According to the implant characteristics, implant location and duration were closely related to PI(p<0.05). Therefore, the PT & PCI is one of the effective methods to reduce the failure caused by the peri-implantitis. Based on this conclusion, that it would be meaningful if the proposed PT & PCI is applied to the oral health management programs of the implant patients.