• 제목/요약/키워드: cleaning apparatus

검색결과 22건 처리시간 0.034초

자탈형 콤바인의 선별모델 (Cleaning Model of Head-feeding Combine)

  • 김상헌;강화석;제임스 엠 그레고리
    • Journal of Biosystems Engineering
    • /
    • 제19권1호
    • /
    • pp.22-32
    • /
    • 1994
  • The combine harvester is considered as an important but complicated and costly machine. The appropriate size of combine has to be developed to use efficiently in Korea. But the combine is such a complicated machine that a complete design model to develop a new type is impossible without understanding the relationship between each factor. The combine capacity is generally limited by the cleaning shoe performance. So a design model for a cleaning shoe has to be developed first for the complete combine design. The objective of this research was to develop a cleaning model of head-feeding combine to predict grain separation from chaff and broken straw on a sieve. A developed physically based model can explain the situation which can happen during separation process. A test apparatus based on the field going machine was developed. The test materials were paddy rice and barley. The data obtained were analyzed by the hand and the video camera. The developed model was verified as an adequate model through the test with $R^2$ of 0.934 and 0.837. The model can be used to evaluate design and operation alternatives of combine and also applied to the automatic control of separation unit of combine with a loss monitering sensors.

  • PDF

디젤 자동차용 매연저감장치(DPF)의 클리닝 성능 고도화에 관한 연구 (Study on the high efficiency cleaning performance of the diesel vehicle DPF)

  • 김형준;정재우;강정호;이진우;박정수
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.163-170
    • /
    • 2016
  • 디젤 자동차의 배기가스 규제는 매년 지속적으로 강화되고 있다. 최근 HC, CO, NOx, PM에 대한 배기 규제는 매우 엄격한 기준을 적용하고 있다. 향후에는, 입자상 물질의 수량규제로 더욱 강화될 것으로 예상되고 있다. 이에 따라, 현재 대부분의 디젤 차량은 PM 저감을 위해 배기후처리징치(DPF)를 적용해 왔다. 엔진의 주행거리가 증가함에 따라, 엔진 배기가스에 포함된 재와 soot이 DPF내부에 축적된다. 축적된 재와 soot은 DPF 손상이나 엔진 성능 악화의 원인이 된다. 그러므로 효율적인 DPF의 클리닝은 엔진관리 측면에서 매우 중요한 부분이다. 만약 엔진이 주기적 클리닝을 통해 관리가 잘 된다면 엔진의 출력과 연비를 개선하고, 유지관리 비용을 절감할 수 있다. 따라서, 본 연구에서는 DPF 내부에 누적된 재와 soot을 효과적으로 클리닝 할 수 있는 고효율 DPF 클리닝 방법 및 장치의 개발을 수행하였고, 그 결과를 제시하였다.

Improving the Precision of Specifications by Evaluating the Influence of Test Parameters on Tribological Results - A Synthesis from a Series of International - Round Robin Tests -

  • Woydt Mathias;Weber Hartwig
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.164-180
    • /
    • 2003
  • A series of cooperative interlaboratory tests (round robins) was conducted in 1997, 1998, 1999, 2000, 2001, 2002 and 2003 by the DIN 51834 Working Group on Tribological Tests in Translatory Oscillation Apparatus. The statistical analysis of these test results shows the influence of cleaning solvent, machine model and evaluation criteria on the tribological properties of the lubricants tested. Coefficients of friction and wear results are ranked according to the effects of ten different cleaning solvents, where isopropanol gave the lowest values and isoparaffin solvents the highest. The effect of machine model on coefficients of friction varied from about $0.2\%\;to\;0.9\%$ of the mean. Wear results were not affected. The tests also showed that the seizure criteria and methods of measuring wear required for in the test procedure do not provide a suitable measure of the tribological properties of some lubricants. The precision was Improved by introducing a grease apply caliper as well as an increased stroke to 1,5 mm and running-in. The temperature does not affect the precision of the oil test procedure.

  • PDF

다공질정압공기 Bearing을 이용한 고정도 회전 Table의 성능 (The Performance of High-Precision Rotary Table Using Externally Pressurized Porous Gas Bearing)

  • 한응교;김기중
    • 한국정밀공학회지
    • /
    • 제1권2호
    • /
    • pp.47-57
    • /
    • 1984
  • The porous matterials are used both to control the flow of the compressed gas and to serve as the bearing surface. This porous design offers several advantages over the conventional externally pressurized gas bearings. It can simplify the construction, lower the gas consumption, and make the cleaning of the gas supply less critical. Test apparatus was cinstructed to experi- mentally investigate maximum load capacity of thrust bearing was measured 200 Kg (15Kg/$\mu$m), and radial bearing was 36 Kg/$\mu$m. And a rotation accuracy of face waving was 0.0127$\mu$m, and center waving was measured 0.5 $\mu$m. Finally, the use of this method of design and manufacturing will contribute to many practical application in the field required for precision and high stability.

  • PDF

석영 유리의 파괴 거동에 관한 연구(II) (A Study on the Fracture Behavior of Quartz Glass(II))

  • 최성대;정선환;권현규;정영관;홍영배
    • 한국산업융합학회 논문집
    • /
    • 제10권4호
    • /
    • pp.213-219
    • /
    • 2007
  • Glass-to-metal contact should be prevented in the design of any structural glass component. Because glass is extremely brittle and will fracture readily if even a small point load is applied. If the assembly includes a glass component supported by metallic structure, designers should provide a pliable interface of some kind between the two parts. But there happens high demand of glass-to metal contact in semiconductor industries due to adoption of dry cleaning process as one of the good solution to reduce running cost - carry out equipments cleaning with high corrosive and etching gas such as CF4 with keeping process temperature as the same as high service temperature. Therefore the quartz glass have to be received compression by direct contact with metal as the form of weight itself and vacuum pressure and fatigue by vibrations caused by process during the process. In this paper investigation will be carried out on fracture behavior of quartz glass contacted with metal directly under local load and fatigue given by process vibration with apparatus which can give $lox{\backslash}cal$ load and vibration through PZT ceramics to give guideline to prevent unintended fracture of quartz glass.

  • PDF

기류방출형 연X선 조사에 의한 정전기 제거 장치에 관한 연구 (A Study on the Removal of Electrostatic using Transmitted Ions Generated Soft X-ray with Compressed Air)

  • 귄승열;이동훈;최재욱;서민석
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.27-31
    • /
    • 2010
  • It is a well known fact that the LCD and Semiconductor Devices are a central part of IT industry which is important in the present and the future. But the biggest problem of Semiconductor and LCD manufacturing is maintaining a cleaning room environment. For this reason, the soft X-ray type Ionizer was used as the electrostatic reducer device, which protects damage of the product against electrostatic discharge in the manufacturing process. Therefore it is a essential important factor during Semiconductor and LCD production process. But the soft X-ray has a intrinsic problem with harmful to human being in case of soft X-ray exposure. That's reason we have the research to solve above problem and made an apparatus that it was covered with shielding structure to protect X-ray radiation to outside. And besides, it has a possibility to eliminate the charged electrostatic in the narrow space through the slot for Ion emissions with dual soft X-ray sources on the both side. It is also not make the particles from itself when it has been operated.

습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성 (SOx and NOx removal performance by a wet-pulse discharge complex system)

  • 박현진;이환영;박문례;노학재;유정구;한방우;홍기정
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.

Work Conditions and Practices in Norwegian Fire Departments From 1950 Until Today: A Survey on Factors Potentially Influencing Carcinogen Exposure

  • Jakobsen, Jarle;Babigumira, Ronnie;Danielsen, Marie;Grimsrud, Tom K.;Olsen, Raymond;Rosting, Cecilie;Veierod, Marit B.;Kjaerheim, Kristina
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.509-516
    • /
    • 2020
  • Background: Meta-analyses have shown firefighters to be at an increased risk of several cancer types. Occupational carcinogen exposure may explain these increased risks. This study aims to describe Norwegian fire departments' work conditions from 1950 until today, focusing on factors relevant for potential occupational carcinogen exposure. Methods: With the help of a reference group, we developed a questionnaire on topics related to occupational exposure to carcinogens for the period 1950-2018. Selected Norwegian fire departments provided department-specific responses. Results: Sixteen departments, providing fire services for 48% of the Norwegian population as of 2019 and mainly consisting of professional firefighters, responded to our questionnaire. The introduction of synthetic firefighting foams, more regular live fire training, the introduction of chemical diving, and a higher number of diesel-driven fire service vehicles were identified as changes thought to increase exposure to occupational carcinogens. Changes thought to decrease exposure included the switch from negative to positive pressure self-contained breathing apparatuses, the use of self-contained breathing apparatuses during all phases of firefighting, the use of ventilating fans during firefighting, increased attention to flammable materials used during live fire training, increased attention to handling and cleaning of turnout gear and other equipment, and installment of exhaust removal systems in apparatus bays. Conclusion: Norwegian fire departments' work conditions have seen several changes since 1950, and this could influence firefighters' occupational carcinogen exposure. A peak of carcinogen exposure may have occurred in the 1970s and 1980s before recent changes have reduced exposure.

초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(II) : 막의 재질, 용질과 복합초음파의 효과 분석 (Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(II) : Analysis of Membrane Materials, Solutes and Multi-ultrasonic Effect)

  • 김석완;임재림;이준걸
    • 대한환경공학회지
    • /
    • 제28권2호
    • /
    • pp.207-215
    • /
    • 2006
  • 본 연구에서는 화학적 1차 처리 침출수(시료 I)와 생물학적 처리 침출수(시료 II)를 대상으로 한 막 분리 공정에서 막의 막힘현상을 개선하기 위한 기술로서 초음파 조사방법을 도입하여 그에 대한 영향을 평가하였다. 초음파의 투과속도 개선효과에 관한 실험은 주기적으로 초음파를 조사할 수 있는 초음파막 분리장치를 제작하여 막의 재질(PS과 PVDF)과 막의 종류(MF와 UF), 초음파의 단일주파수(40 kHz와 120 kHz), 초음파의 세기(200 W와 400 W)에 따라 실시하였으며. 아울러 40 kHz와 120 kHz를 동시에 사용하는 복합초음파 조사 실험을 실시하였다. 주기적인 초음파 조사에 관한 시나리오 실험을 통해 UF막과 MF막을 비교한 결과 MF계열의 막에서 더 높은 투과속도의 개선효과를 나타냈으며, 두 가지 PS와 PVDF재질로 만들어진 MF막의 경우 PVDF재질의 MF막이 더 높은 개선효과를 지속적으로 나타내었다. 또한 용액(폐수)의 특성에 따라 초음파 조사에 의한 투과속도의 개선효과가 다르게 나타났으며, 두 가지 초음파주파수(40 kHz과 120 kHz)를 동시에 활용한 복합초음파를 주기적으로 조사한 경우에 투과속도의 상승률은 세정효과가 큰 낮은 주파수(40 kHz)의 단일초음파를 이용하는 경우보다 작았으나, 재막힘 현상은 복합초음파를 사용하는 경우가 더 크게 억제되어 막의 투과속도 개선효과가 지속적으로 유지되었다.

임상에서의 현미경: 작동, 유지보수 및 레이저 안전 (Clinical Microscopy: Performance, Maintenance and Laser Safety)

  • 이태복
    • 대한임상검사과학회지
    • /
    • 제51권2호
    • /
    • pp.125-133
    • /
    • 2019
  • 임상병리 검사분야에 있어서 환자로부터 유래된 조직이나 세포의 형태학적 변화, 세포 생리, 세포 내 분자의 추적 및 신호전달 체계 등의 임상검사 및 관련 연구를 위한 빼놓을 수 없는 주요한 진단과 연구장비로서 현미경이 가지는 의미는 크다고 할 수 있다. 현미경에 대한 포괄적인 지식과 이해를 바탕으로 현미경의 올바른 사용, 관리와 유지보수는 신뢰도 높은 이미지 획득과 그에 따른 정확한 데이터 분석을 통한 질병의 진단을 위해서 반드시 요구되는 부분이라고 할 수 있다. 광학현미경의 표준 운영 절차(standard operating procedure, SOP)는 현미경의 작동 절차와 함께 검사실 규모에 따른 현장 사용자의 체계적인 현미경 장해 해결 방안과 기계적 원리에 대한 핵심 정보가 함께 수록되어야 한다. 현미경 유지관리 업무에는 대물, 접안렌즈와 현미경 내부 광학필터의 청소, 광원의 교체와 교정, XY재물대 유지보수, 공초점 레이저 주사 현미경(confocal laser scanning microscope)에서의 점확산함수(point spread function, PSF) 측정, 형광현미경에서의 검사 품질관리(quality control, QC)와 체계적인 현미경 장해 해결방안 등이 포함되어야 한다. 본 종설에서는 국제적 기준에 따른 레이저의 위험도에 따라 일부 현미경에 장착된 레이저 광원에 대한 안전지침과 보호장구에 대한 내용을 함께 소개하였다. 현미경을 통해 획득된 이미지는 촬영된 시점의 검체에 대한 모든 정보를 제공한다고 할 수 있으며, 적절한 유지보수 프로그램과 그에 따라 적합하게 관리된 현미경만이 이미지 데이터를 통한 정보의 획득, 올바른 해석과 정확한 진단에 반드시 필요한 선제 조건들이라고 하겠다.