• Title/Summary/Keyword: class factor

Search Result 1,245, Processing Time 0.027 seconds

A study on the Physiological Character of living Space in Traditional Koaean House - Focsed on the rural house in Chonbuk province - (전통주거(傳統住居) 공간의 생리적(生理的) 특성(特性)에 관한 연구 - 전북지방 농촌주택(農村住宅)을 중심으로 -)

  • Kim, Yong-Jip
    • Journal of architectural history
    • /
    • v.8 no.2 s.19
    • /
    • pp.59-72
    • /
    • 1999
  • The purpose of this study is to find the spatial factors, strucure of living and activity in traditional Korean house through the Phiysiological view, Spatial factors of the house are concerned to the interior environment and sanitary condition, The elements of respiratory, nerve, temperature sence. vision, hearing, smelling have good condition and touch, pressure sence, pain, metabolism are poor in the house, Ventilation, Lighting, pleasant condition of interior environment are concerned to the elements that mentioned above and have most important meaning in the relation rate of space as 1st factor. And 2nd factor is for metabolism, housework and rest, 3rd factor ie for temperature sence, privacy and reproduction. The relation rate of factors concering interior environment are high in the upper class house. Anbang has important meaning in the relation of living structure and relation sequence of space is anbang, Konnonbang, kitchen, toilet, water place, auxiliary buildings. The relation rate of activity is high in interior space in winter and exterior space in summer.

  • PDF

An Analysis of the Body Measurement for Children′s Clothing Design (아동복 설계를 위한 신체계측분석 연구)

  • 윤정혜;조윤주;박정순
    • The Research Journal of the Costume Culture
    • /
    • v.3 no.2
    • /
    • pp.293-306
    • /
    • 1995
  • The purpose of this study is to analysis children's measurement and to provide the fundamental information for he clothing design which can reflect the characteristic of their bodies. An anthropometric database used for this study was the 1992 national anthropomatric survey of Koreans. The results obtained are as follows; (1) Children showed the significant difference of their growth in accordance with the increase of their ages. There were also the difference between body and girls. Height, length of items grew most promthy. For example; boys from 10 to 11 and girls from 10 to 11 again their height mostly. (2) In character of body proportion, significant difference were found in accordance with their ages and sex. However, in the items of height, length noticeable changes of proportion could not be found because there were hardly any actual difference of size means while girth items appeared differently. (3) There were significant factors from the result of factor analysis of body dimension. The fist factor ; grith, depth, breath. The second factor ; height, length. (4) We can class three groups with the results of cluster analysis of body dimension.

  • PDF

Development of Classification Model Using Neural Network (신경회로망을 이용한 분류모형 개발)

  • Park, Kwang-Bak;Park, Young-Man;Hwang, Seung-Gook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.5
    • /
    • pp.638-641
    • /
    • 2008
  • In this paper, a model to classify the method using the fuzzy TAM with preprocessing of data was developed. The preprocessing method can be divide the problem using the characteristics in the case of category type factor. In case of continuous type factor, if there was exist factor's range which is not overlapping by class, the data belong to the range was fixed and eliminated in classification. After these preprocessing of data, classified operation of Fuzzy TAM is performed.

Effects of transforming growth factor .betha.1 and interleukin-2 on IgA isotype switching at the clonal level

  • Kim, Pyeung-Hyeun
    • The Microorganisms and Industry
    • /
    • v.16 no.3
    • /
    • pp.2-5
    • /
    • 1990
  • IgA is the predominant immunoglobulin isotype in mucosal secretions(1). It has been reported that a population of Peyer's patch T cells can selectively induce IgM bearing B cells to switch to surface IgA bearing B cells(2,3). Further, IL-4, IL-5, and IL-6 alone and in combination, can significantly influence murine IgA B cell differentiation in vitro(4-7). However, it remains an open question which cytokines have a major role in class switching to the IgA isotype. Recently, it has been reported that transforming growth factor .betha.1(TGF .betha.1) alone, or in combination with IL-2 increases IgA secretion by LPS-activated surface IgA negative (sIgA$\^$-/) murine spleen B cells while concurrently downregulating IgM and IgG secretion by such cells(8-11). In the present study, limiting dilution analysis was used to demonstrate, at the clonal level, that TGF .betha.1 has siginificant activity as an IgA isotype switch factor.

  • PDF

A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System (분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰)

  • Kim, Jae-Eon;Jo, Seong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.

  • PDF

A study on development of 30GW class high power glass laser system (30GW급 대출력 글라스레이저의 개발연구)

  • 강형부
    • 전기의세계
    • /
    • v.31 no.5
    • /
    • pp.383-390
    • /
    • 1982
  • The high power glass laser system was designed and constracted which consisted of a TEM$\_$00/ mode Q-switching oscillator, a pulse shaping, system, two-stage pre-amplifiers, five-stage main amplifiers, a Faraday rotator, and a uni-guide slit. The laser output of 3OGW with the pulsewidth of 2 nsec was obtained by performing the amplifiing experiment in this system. When the laser light with the pulsewidth of 10 nsec was amplified, the large factor of amplification was obtained in the beginning of pulse, but the factor of amplification decreased gradually in the later part of pulse. Therefore, the laser light which has short pulsewidth of-2nsec must be amplified in order to obtain the larger factor of amplification. When the laser beam from the high power glass laser system was irradiated to plasma, the reflected laser light from plasma which occured inevitably could be attenuated to the order of 10$\^$-4/ by using the Faraday rotator and the uni-guide slit.

  • PDF

Comparison between Expected and Actual Capacity Factors of a Wind Farm (풍력발전단지의 예측이용율과 실제이용율 비교분석에 관한 연구)

  • Koh, Byung-Euk;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2011
  • This study shows the comparison between expected and actual capacity factors of a wind farm through wind resource analyzation. The expected capacity factor comes from an 'automatic weather system' run by the Korean national weather service and a 'meteorological mast' run by a project owner. Based on this comparison and analysis, the importance of meteorological mast micro-siting and selection of wind turbine class and type, will be studied along with presenting important implications for wind farm expansion and development.

  • PDF

A Study of AC-DC PWM Full-Bridge Integrated Converter Topologies

  • Gerry, Moschopoulos;Praveen Jain
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.107-116
    • /
    • 2001
  • Two AC-DC PWM full-bridge converters that can input current to improve input power factor while performing dc-dc conversion are investigated in this paper. Both converters are simple in that they are similar to the standard PWM full-bridge converter with a diode rectifier/LC low-pass filter input, and both can operate with a simple method of PWM control. In the paper, the operation of the converters is explained and their steady-state characteristics are discussed. The feasibility of the converters and their ability to meet EN61000-3-2 Class D Standards for electrical equipment are shown with results obtained from experimental prototypes. The performance of both converters in terms of dc bus voltage level, input power factor and efficiency is compared and discussed.

  • PDF

NMR Study of Consensus DNA-binding Site for Arabidopsis thaliana Class I Transcription Factor AtTCP1

  • Choi, Yong-Geun;Kim, Hee-Eun;Lee, Joon-Hwa
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.2
    • /
    • pp.76-80
    • /
    • 2013
  • The TCP domain is a DNA-binding domain present in plant transcription factors and has a similar structural feature to the bHTH motif of eukaryotic transcription factors. The imino proton exchange study has been performed for the DNA duplex containing the consensus DNA-binding site for the AtTCP11 transcription factor. The first two base pairs in the consensus 5'-GTGGG-3' sequence are relatively very unstable but lead to greater stabilization of the neighboring two G C base pairs. These unique dynamic features of the five base pairs in the consensus DNA sequence might play crucial roles in the effective DNA binding of the AtTCP11 protein.

Study on the Power Factor Correction Circuit Applying Multiple Coupling Inductor with Expandable Integrated Magnetic Structure (확장형 자기 구조의 다중 결합 인덕터를 적용한 역률개선회로에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • In this paper, a multiple coupling inductor with expandable-integrated magnetic structure was proposed to enable miniaturization of external switched mode power supply (SMPS) for a large display. Inductance formula of the proposed inductor structure was derived through magnetic circuit analysis for a simple inductance designing process. The proposed inductor was applied into a 1kW class interleaved bridgeless power factor correction circuit which requires four inductors, and experimental steady state result of the circuit was compared. According to the experimental result, it was found that the proposed multiple coupling inductor shows the electrical characteristics that can replace the conventional separated inductors and is suitable for miniaturization of the SMPS since the circuit configuration is possible with one shared inductor.