• Title/Summary/Keyword: clamping

Search Result 739, Processing Time 0.027 seconds

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

A Study on The Change of Insert Clamping Force Influence According to the Surface Treatment of Armor Aluminum Alloy Plate (장갑판재의 표면처리에 따른 인서트 체결력 변화 연구)

  • Hwang, Bu Il;Yang, Sang Hun;Kim, Chi Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.787-791
    • /
    • 2015
  • In some cases which are unable to replace the inserts when the depot maintenance or performance improvement of armored vehicles are carried out could have a risk of declining clamping forces by re-processing chromate. The change in the clamping forces of inserts has been investigated by applying a chromate process to hold the insert on the aluminum plate of the armored vehicle in this paper. In order to identify the effect of types and surface treatment, the breaking strength has been measured by the equivalent test item to the actual conditions. These tests would contribute the establishment of the armored vehicle production process.

A Study on Cycle Time and Power Saving Effect of a Hydraulic Hybrid Injection Molding Machine using a Servo Motor (서보모터를 이용한 유압 하이브리드식 사출성형기의 공정시간 및 절전효과에 관한 연구)

  • Yun, Hongsik;Kim, Sungdong
    • Journal of Drive and Control
    • /
    • v.17 no.3
    • /
    • pp.15-25
    • /
    • 2020
  • The cycle time and power saving effect of a hydraulic hybrid injection molding machine using a servo motor are considered in this paper. In order to verify control characteristics, such as pressure and speed, experiments were performed with the hydraulic hybrid injection molding machine, clamping force of 110 ton. The power consumption and production cycle time of a conventional hydraulic injection molding machine were measured to compare its performances with the hydraulic hybrid injection molding machine. An injection molding machine with a clamping force of 1300 ton was used as the conventional machine, the hybrid machine was implemented by replacing its induction motors with servo motors. In the remodeled hybrid machine, experiments were performed to investigate how the displacement of the mold clamping pump affects the power consumption and production cycle time. The results showed that the production cycle time of the hybrid injection molding is similar to a conventional hydraulic injection molding machine but with a significant energy saving of about 40%.

Fabrication of Glass-Ceramic Coacted Electrostatic Chucks by Tape Casting (테이프캐스팅에 의한 결정화유리 도포형 정전척의 제조)

  • 방재철;이경호
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.05a
    • /
    • pp.169-172
    • /
    • 2002
  • This study demonstrated the feasibility of using tape-casting followed by sintering as a low-cost alternative for coating glass-ceramic or glass film on a metal substrate. The process has been successfully used to fabricate a glass-on-stainless steel and a glass-ceramic-on-molybdenum electrostatic chuck(ESC) with the insulating layer thickness about $150{\mu}{\textrm}{m}$. Electrical resistivity data of the coaling were obtained between room temperature and 55$0^{\circ}C$; although the resistivity values dropped rapidly with increasing temperature in both coatings, the glass-ceramic still retained a high value of $10^{10}$ ohm-cm at $500^{\circ}C$. Clamping pressure measurements were done using a mechanical apparatus equipped with a load-cell at temperatures up to $350^{\circ}C$ and applied voltages up to 600V; the clamping behavior of all ESCs generally followed the voltage-squared curve as predicted by theory. Based on these results, we believe that we have a viable technology for manufacturing ESCs for use in reactive-ion etch systems.

  • PDF

A Study on the Estimation of Separation Forces of a Power Steering Hose Assembly (동력조향장치 호스 조립품의 이탈력 추정에 관한 연구)

  • Kim Hyungje;Kim Byungtak;Yoon Moonchul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.190-196
    • /
    • 2005
  • The power steering hose assembly is usually manufactured through the swaging process, which is conducted to connect a hose with metal fittings. In this process the hose is inserted into metal components, the sleeve and the nipple, and compressed in the radial direction by the jaws to clamp the hose with metal components. In case that the clamping force is small, the oil in the hose can leak locally under the severe operating conditions. To confirm the clamping force requirements, the measurement of separation force in longitudinal direction of the hose is usually performed. In this study, the swaging process of a hose is simulated with the finite element method, to investigate the effect of friction coefficient on the separation fDrce. The results interpretations are ffcused on the inner rubber component, and also a formula is proposed to estimate the separation farces with respect to friction coefficients.

Optimization of feed system of base mold for washing machine using CAE (사출성형 CAE를 이용한 세탁기용 Base 성형용 금형의 유동 시스템 최적화)

  • Yoo, Min-ji;Kim, Kyung-A;Han, Seong-Ryeol
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • The position of the gate is one of the important factors for optimal injection molding. This is because inappropriate gate positions cannot fill the cavity uniformly, which can lead to defects such as contraction. In this study, CAE was performed on hot runner injection molding of the washing machine base and plasticity was compared by changing gate position from existing gate position. A total of two alternatives have been applied to compare the plasticity of the washing machine base according to its optimal gate position. The gate position of the improved molds and the gate position of the current mold is analyzed by injection molding analysis. The results of the fill time, the pressure at V/P switchover, clamping force, and deflection were compared. In washing machine base injection molding, the deflection was reduced by about 3.76% in the improved mold 2. In improved mold 1, the fill time during injection molding was reduced by 3.32% to enable uniform charging, and the clamping force was reduced by 31.24%. We have confirmed that the position of the gate can change the charging pressure and the clamping force and affect the quality and cost savings of the molded product.

PNA-Mediated PCR Clamping for the Detection of EGFR Mutations in Non-Small Cell Lung Cancer (비소세포폐암에서 PNA-Mediated PCR Clamping을 이용한 EGFR 돌연변이 분석법)

  • Lee, Kye-Young;Kim, Hee-Joung;Kim, Sun-Jong;Yoo, Gwang-Ha;Kim, Won-Dong;Oh, Seo-Young;Kim, Wan-Seop
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.4
    • /
    • pp.271-278
    • /
    • 2010
  • Background: Recent studies have demonstrated that the epidermal growth factor receptor (EGFR) genotype is the most important predictive marker to EGFR-tyrosine kinase inhibitors (TKIs) and first-line gefitinib treatment will be approved in the near future for use in non-small cell lung cancer (NSCLC) patients with the EGFR mutation. Direct sequencing is known to be the standard for detecting EGFR mutations; however, it has limited sensitivity. Peptide nucleic acids (PNA)-mediated PCR clamping method is a newly introduced method for analyzing EGFR mutations with increased sensitivity and stability. Methods: A total of 71 NSCLC patients were analyzed for EGFR mutations using the PNA-mediated PCR clamping technique. Sixty-nine patients were analyzed for clinicopathologic correlation with EGFR genotype; 2 patients with indeterminate results were excluded. In order to determine EGFR-TKI drug response, 57 patients (42 gefitinib, 15 erlotinib) were included in the analysis. Results: The EGFR mutation rate was 47.8%. Being female, a non-smoker, and having adenocarcinoma were favorable clinicopathologic factors, as expected. However, more than a few smokers (33.3%), male (28.1%), and patients with non-adenocarcinoma (28.6%) had the EGFR mutation. Having a combination of favorable clinicopathologic factors did not increase the EGFR mutation rate significantly. Drug response to EGFR-TKIs showed significant differences depending on the EGFR genotype; ORR was 14.3% for wild type vs 69.0% for mutant type; DCR is 28.6% for wild type vs 96.6% for mutant type. The median EGFR-TKI treatment duration is 7.6 months for mutant type group and 1.4 months for wild type group. Conclusion: EGFR genotype determined using the PNA-mediated PCR clamping method is significantly correlated with the clinical EGFR-TKI responses and PNA-mediated PCR.

A Brake Pad Wear Compensation Method and Performance Evaluation for ElectroMechanical Brake (전기기계식 제동장치의 제동패드 마모보상방법 및 성능평가)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Park, Choon-Soo;Kim, Seog-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.581-588
    • /
    • 2020
  • This study examined a brake pad wear compensation method for an Electro-Mechanical Brake (EMB) using the braking test device. A three-phase Interior Permanent Magnet Synchronous Motor (IPMSM) was applied to drive the actuator of an EMB. Current control, speed control, and position control were used to control the clamping force of the EMB. The wear compensation method was performed using a software algorithm that updates the motor model equation by comparing the motor output torque current with a reference current. In addition, a simple first-order motor model equation was applied to estimate the output clamping force. The operation time to the maximum clamping force increased within 0.1 seconds compared to the brake pad in its initial condition. The experiment verified that the reference operating time was within 0.5 seconds, and the maximum value of the clamping force was satisfied under the wear condition. The wear compensation method based on the software algorithm in this paper can be performed in the pre-departure test of rolling stock.

Effective Biomarkers for Miniature Pig in Acute Kidney Injury Using Renal Ischemia-Reperfusion Model (미니돼지의 신허혈-재관류에 의한 급성신손상 모델에서의 유용한 바이오마커)

  • Kim, Se-Eun;Shim, Kyung-Mi;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.372-376
    • /
    • 2012
  • Acute kidney injury (AKI) is a serious problem associated with high morbidity and mortality. Ischemia-reperfusion is an important cause of acute kidney injury. This study was performed to ascertain clinically useful biomarkers for the diagnosis of AKI. In three miniature pigs, AKI were induced by 60 minutes of bilateral renal ischemia by the clamping renal artery. Blood and urine samples were collected from the pigs prior to clamping (baseline) and 0, 1, 3 and 5 days post-clamping. Serum blood urea nitrogen (BUN), creatinine, sodium and uric acid were measured in serum and urine samples. Fractional excretion of sodium ($FE_{Na}$) and fractional excretion of uric acid ($FE_{UA}$) were calculated. Also, interleukin (IL)-6, IL-18, liver type fatty acid binding protein (L-FABP) and glutathione-S-transferase (GST) were detected by Western immunoblotting. Serum BUN and creatinine levels were increased significantly at day 1 post-clamping in all three miniature pigs. However, $FE_{Na}$ and $FE_{UA}$ showed marked individual differences. Western immunoblotting revealed significantly increased levels of IL-6, IL-18, L-FABP and GST in post-ischemic urine, compared to pre-clamping. While more research concerning the variance of $FE_{Na}$ and $FE_{UA}$ is needed, serum BUN, creatinine, IL-6, IL-18, L-FABP and GST may be sensitive urine biomarkers for diagnosis of AKI together with other biomarkers in the porcine ischemia-reperfusion model.

Study of pH and Gas Analysis of Umbilical Arterial Blood and Apgar Score as Indicators of Newborn Health (신생아 건강지표로서 제대동맥혈의 pH와 Gas Analysis 및 Apgar Score에 관한 연구)

  • Cho, Dae-Hyun;Lee, Mi-Na;Koh, Min-Whan;Lee, Tae-Hyung;Lee, Sung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.98-106
    • /
    • 1991
  • Apgar score is most widely used evaluating indicator of newborn health, but it is very Subjective. Umbilical cord blood gas analysis is more objective and effective than Apgar score in evaluation of newborn status. Cord blood gas was changed slightly by processing of time after fetal birth. This study was undertaken to observe objectiveness and effectiveness of umbilical arterial blood gas analysis and effects of time interval of cord clamping to newborn health with 122 pregnant women and their babies. We observed following results : 1. There were poor correlation between Apgar score and umbilical cord arterial blood analysis in evaluating of newborn health (P>0.05). 2. There was no clinical significance of Apgar score or umbilical arterial blood gas analysis as single indicator in evaluating of newborn health (P>0.05). 3. Gas analysis and pH of umbilical arterial blood was more helpful in evaluating of newborn health than Apgasr score. 4. There were no significant effects of time interval of umbilical cord clamping to newborn health. 5. If there were no indications of early umbilical cord clamping, cord blood sampling at immediately after birth without cord clamping was more effective to evaluate newborn status.

  • PDF