• 제목/요약/키워드: chloride content test

검색결과 166건 처리시간 0.012초

Corrosion of Steel in Blended Concretes Containing OPC, PFA, GGBS and SF

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn Chu
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.171-176
    • /
    • 2009
  • The chloride threshold level (CTL) in mixed concrete containing, ordinary Portland cement (OPC), pulverized fuel ash (PFA) ground granulated blast furnace slag (GGBS), and silica fume (SF) is important for study on corrosion of reinforced concrete structures. The CTL is defined as a critical content of chloride at the steel depth of the steel which causes the breakdown of the passive film. The criterion of the CTL represented by total chloride content has been used due to convenience and practicality. In order to demonstrate a relationship between the CTL by total chloride content and the CTL by free chloride content, corrosion test and chloride binding capacity test were carried out. In corrosion test, Mortar specimens were cast using OPC, PFA, GGBS and SF, chlorides were admixed ranging 0.0, 0.2, 0.4, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder. All specimens were cured 28 days, and then the corrosion rate was measured by the Tafel's extrapolation method. In chloride binding capacity, paste specimens were casting using OPC, PFA, GGBS and SF, chlorides were admixed ranging 0.1, 0.2, 0.3, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binders. At 28days, solution mixed with the powder of ground specimens was used to measure binding capacity. All specimens of both experiments were wrapped in polythene film to avoid leaching out of chloride and hydroxyl ions. As a result, the CTL by total chloride content ranged from 0.36-1.44% by weight of binders and the CTL by free chloride content ranged from 0.14-0.96%. Accordingly, the difference was ranging, from 0.22 to 0.48% by weight of binder. The order of difference for binder is OPC > 10% SF > 30% PFA > 60% GGBS.

염화칼슘이 함유된 제설제로 인한 콘크리트 바닥판 단부의 염해에 관한 사례 연구 (A Case Study on Chloride Corrosion for the End Zone of Concrete Deck Subjected to De-icing Salts Added Calcium Chloride)

  • 정지승;김보헌;김일순
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.87-93
    • /
    • 2014
  • In this study, the reinforced concrete rahmen bridge damaged by the chloride attack was investigated. According to the investigation, the degraded concretes on cantilever kerb and end part were intensively observed. Thus, the chloride content test and half-cell method were performed to evaluate the degraded parts. As a result, the contents of chloride on degraded parts were C and D grade. On the other hand, the half-cell potential values of rebar in degraded concrete were measured with the minor corrosion. This rebar corrosion is expected to progressing. Chloride content D grade is due to expansion pressure by corrosion of rebar and freeze-thaw by permeate water, could see progresses rapidly degradation. In order to prevent chloride attack to concrete deck caused by deicing salts, corresponding to the chloride critical concentration must maintain grade b or at least grade c. Chloride condition evaluation standard apply to evaluation of marine structure chloride attack with chloride attack by deicing salts.

An Experimental Study on the Properties of Concrete using High Volume of Coal Ash

  • Kim, Moo Han;Choi, Se Jin
    • Architectural research
    • /
    • 제4권1호
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, the coal-ash production has been increased by increase of consumption of electric power. So it is important to secure a reclaimed land from pollution and develop practical application of coal ash. This is an experimental study to compare and analyze the properties of concrete using high volume of coal ash (including fly ash and bottom ash) as a part of fine aggregate. For this purpose, the mix proportions of concrete according to replacement ratio of coal ash (10, 20, 35, 50%) were selected. And then air content, slump, setting time, bleeding content, chloride content, compressive strength and carbonation test were performed. According to test results, it was found that the bleeding content of concrete using the coal ash decreased according to increase of replacement ratio. And the chloride content of concrete using the bottom ash as a part of fine aggregate increased as the replacement ratio of bottom ash increased, but it is satisfied with the total chloride content of concrete recommended by KCI - $0.3kg/m^3$ below. Also, the compressive strength of concrete using the bottom ash was similar to that of plain concrete(BA 0) after 28days of curing and the carbonation depth of concrete increased as the replacement ratio increased. However, the carbonation depth of concrete using the fly ash decreased as the replacement ratio of fly ash increased.

현장 폭로실험에 의한 콘크리트 중 철근의 부식 임계 염화물량 평가 (Estimation of Critical Chloride Content for Corrosion of Reinforcing Steel in Concrete by Field Exposure Experiment)

  • 유경근;배수호;박재임;이광명;김지상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.585-588
    • /
    • 2008
  • 염해환경 하에 있는 철근 콘크리트 구조물의 내구수명을 평가하기 위해서는 콘크리트 중 철근의 부식 임계 염화물량, 콘크리트의 염소이온 확산계수 및 표면 염소이온량과 같은 재료의 정량적인 물성 파악이 필수적이고, 이들이 콘크리트의 내구수명 평가시 주요변수로 이용되고 있다. 그러나, 이들은 콘크리트 배합비, 시멘트 종류 및 환경 조건 등과 같은 여러 요인에 의해 영향을 받는 것으로 알려져 있다. 따라서, 본 연구에서는 콘크리트 중 철근의 부식 임계 염화물량을 보다 실제적으로 평가하기 위하여 물-시멘트비 31%, 42%, 50% 및 70%에 대해서 각주형 콘크리트를 제작한 다음, 이들에 대해서 동해안에 위치한 영덕에서 약 3년 동안 폭로 실험을 수행하였다. 실험이 진행되는 동안, 철근의 부식 개시 시기를 추정하기 위하여 시험체에 대해서 자연전위 측정에 의한 부식 모니터링을 수행하였고, 철근부식이 감지되었을 때 시험체를 파괴한 후 콘크리트 중 염화물량을 평가함으로써 보다 합리적이고 신뢰적인 임계 염화물량을 제시하였다. 결국, 콘크리트 중 철근의 부식 임계 염화물량은 W/C비에 의존하며, 콘크리트 피복두께와는 거의 무관한 것으로 나타났다.

  • PDF

PVA 섬유와 실리카흄 첨가가 알칼리 활성 슬래그의 염화물 침투 저항성에 미치는 영향 (Effect of PVA Fiber and Silica Fume Addition on Chloride Penetration Resistance of Alkali-Activated Slag)

  • 윤현노
    • 도시과학
    • /
    • 제12권2호
    • /
    • pp.13-18
    • /
    • 2023
  • This study investigates the effect of polyvinyl alcohol (PVA) fiber and silica fume addition on the chloride penetration resistance of alkali-activated slag. Silica fume was added to replace slag at the dosage of 0, 5, 10, and 20% by weight of the binder, while PVA fiber was added at the dosage of 0, 1, and 2% by volume of the mixture. Samples were synthesized via alkali activator with 1.0 of silicate modulus and cured at room temperature for 28 days. Compressive strength test, permeable voids volume test, water absorprtion test, and rapid chloride penetration test were conducted for measuring the charaterisitics of alkali-activaed slag. The results showed that increasing silica fume content up to 10% in alkali-activated slag improved compressive strength and chloride penetration resistance. Addition of PVA fibers up to 1% by volume enhanced strength and chloride penetration resistance, but exceeding this led to reduced strength and durability due to increased void formation in the matrix.

Corrosion Behavior of Cr-bearing Corrosion Resistant Rebar in Concrete with Chloride Ion Content

  • Tae, Sung Ho
    • Architectural research
    • /
    • 제7권1호
    • /
    • pp.49-54
    • /
    • 2005
  • Conventional studies have focused on the reduction in the water-cement ratio, the use of various admixtures, etc., to ensure the durability of reinforced concrete structures against such deterioration factors as carbonation and chloride attack. However, improvement in the concrete quality alone is not considered sufficient or realistic for meeting the recent demand for a service life of over 100 years. This study intends to improve the durability of reinforced concrete structures by improvement in the reinforcing steel, which has remained untouched due to cost problems, through subtle adjustment of the steel components to keep the cost low. As a fundamental study on the performance of Cr-bearing rebars in steel reinforced concrete structures exposed to corrosive environments, The test specimens were made by installing 8 types of rebars in concretes with a chloride ion content of 0.3, 0.6, 1.2, 2.4 and $24kg/m^3$. Corrosion accelerated curing were then conducted with them. The corrosion resistance of Cr-bearing rebars was examined by measuring crack widths, half-cell potential, corrosion area and weight loss after 155 cycles of corrosion-accelerating curing. The results of the study showed that the corrosion resistance increased as the Cr content increased regardless of the content of chloride ions, and that the Cr-bearing rebars with a Cr content of 5% and 9% showed high corrosion resistance in concretes with a chloride ion content of 1.2 and $2.4kg/m^3$, respectively.

Chloride penetration in anchorage concrete of suspension bridge during construction stage

  • Yang, In-Hwan;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Advances in concrete construction
    • /
    • 제10권1호
    • /
    • pp.13-20
    • /
    • 2020
  • Steel corrosion in embedded steel causes a significant durability problems and this usually propagates to structural degradation. Large-scaled concrete structures, PSC (Pre-stressed Concrete) or RC (Reinforced Concrete) structures, are usually constructed with mass concrete and require quite a long construction period. When they are located near to sea shore, chloride ion penetrates into concrete through direct or indirect exposure to marine environment, and this leads durability problems. Even if the structures are sheltered from chloride ingress outside after construction, the chloride contents which have been penetrated into concrete during the long construction period are differently evaluated from the initially mixed chloride content. In the study, chloride profiles in cores extracted from anchorage concrete block in two large-scaled suspension bridge (K and P structure) are evaluated considering the exposure periods and conditions. Total 21 cores in tendon room and chamber room were obtained, and the acid-soluble chlorides and compressive strength were evaluated for the structures containing construction period around 3 years. The test results like diffusion coefficient and surface chloride content from the construction joint and cracked area were also discussed with the considerations for maintenance.

비색판별법을 이용한 콘크리트의 표면염화물량 산정 및 매립철근의 건전도 평가 (Calculation of the Surface Chloride and Estimation for the Soundness of Embedded Rebar by Using Colorimetric Distinction Method)

  • 이문환;이진우
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.794-801
    • /
    • 2003
  • 건축물의 요구성능에 대한 관심이 점차 높아짐에 따라 건축물의 성능평가를 통하여 사용연한을 예측하고 건축물의 수명을 연장시키거나, 새롭게 재구성하려는 노력이 계속되고 있다. 그러나 아직 염화물에 의한 성능저하 평가에 있어 그 비용의 문제와 평가과정의 전문성 등의 많은 난점을 가지고 있다. 본 연구는 콘크리트 내부의 염화물침투 깊이를 측정하는 간이적 방법인 비색판별법을 이용하여 염화물에 의한 성능저하평가를 하고자 비색판별법의 적용가능성을 검토 후 변색위치의 침투염화물량을 정량분석하였다. 또한, 이를 이용하여 콘크리트 표면염화물량을 산정하고 철근위치 염화물량의 예측 및 한계염화물량에 도달시간 예측의 실용적 평가수단을 제시하였다. 염화물에 의한 철근콘크리트 구조물의 성능평가에 있어 간이평가 수단인 비색판별법의 활용에 따라 샘플수의 다량확보를 통한 신뢰수준의 향상을 이룰 수 있을 것으로 사료된다.

LIBS를 활용한 수용액과 모르타르 내 염화물량 분석 (Analysis of Chloride Content in Aqueous Solution and Mortar using Laser Induced Breakdown Spectroscopy)

  • 류화성;박원준
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.189-194
    • /
    • 2021
  • 본 연구에서는 Lab. 스케일 LIBS 장치를 제작하여 모르타르 내 염화물 분석에서의 LIBS 적용성과 재현성 검토를 수행하였다. 염화물 함량을 조절한 모르타르를 대상으로 기존의 분석방법(XRF, 전위차 적정법)과 LIBS 분석을 동시에 진행하였다. LIBS 분석 결과, 염소이온은 837.59nm 파장에서 검출되었고, 다양한 농도 구간에서의 정밀도를 향상시키기 위하여 전기장 강화를 통한 약 50배의 LIBS 신호증폭을 구현하였다. 수용액 기반의 재현성을 검증을 통하여 LIBS 신호 강도와 Cl농도 사이의 높은 상관관계를 확인할수 있었으며, 콘크리트 염해 내구성 진단에 LIBS적용 가능성을 확인하였다.

신경망 이론을 이용한 염소이온 겉보기 확산계수 추정 및 이를 이용한 염화물 해석 (Analysis Technique for Chloride Behavior Using Apparent Diffusion Coefficient of Chloride Ion from Neural Network Algorithm)

  • 이학수;권성준
    • 콘크리트학회논문집
    • /
    • 제24권4호
    • /
    • pp.481-490
    • /
    • 2012
  • 염화물 이온은 콘크리트 내부로 유입되어 철근부식을 야기하므로 염화물 침투 평가는 매우 중요하다. 전기영동실험을 통한 촉진확산계수가 현실적으로 많이 쓰이고 있지만, 이는 자유염화물 이온에 대한 전기장 내의 이온속도를 나타낼 뿐이므로 염화물량에 대한 명확한 해를 제공하지 못한다. 겉보기 확산계수는 단순한 Fick의 이론을 배경으로 엔지니어에게 전염화물의 확산을 명확하게 제공할 수가 있다. 이 연구는 인공신경망이론을 이용하여 최적의 확산계수를 도출하고 시간의존성 확산계수를 이용하여 염화물 침투를 평가할 수 있는 기법을 제시하는 것이다. 이를 위해 기존의 연구에서 30개의 배합 및 염소이온 겉보기 염화물 확산계수를 인용하였으며, 배합인자(물결합재비, 단위시멘트량, 슬래그, 플라이애쉬, 실리카퓸, 단위 잔골재 및 굵은 골재)를 뉴런으로 선택하여 확산계수에 대한 학습을 훈련하였다. 또한 시간의존성 확산계수를 고려하여 단순한 Fick 법칙으로 염화물 침투를 평가할 수 있는 기법을 제시하였다. 장기침지실험 및 실태조사 결과를 이용하여 제안된 기법의 결과와 비교를 수행하였으며, 그 적용성을 평가하였다. 이 기법은 다양한 배합 및 관련 확산계수의 입수 및 학습을 통하여 더욱 합리적인 기법으로 발전할 수 있다.