• Title/Summary/Keyword: chemical facility

Search Result 384, Processing Time 0.037 seconds

A Study on the new MBT management system with variations of MSW's seasonal emission characteristics (생활폐기물의 계절별 성상변화에 따른 MBT 시스템 관리에 관한 연구)

  • Min, Byong-Hoon;Chung, Chan-Kyo;Kim, Jong-Moon;Min, Dul-le;Lim, Seung-Bin;Lee, Chae-Young;Kim, Hyung-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.4
    • /
    • pp.54-63
    • /
    • 2010
  • When MBT(Mechanical Biological Treatment) facility is designed, the management system adequate for domestic circumstance in Korea has been insufficient and power plant's load on seasonal variation has not been resolved yet. Thus, this study introduced MBT facility and MSW(Municipal Solid Waste)'s seasonal emission characteristics were investigated in order to establish new MBT management system. and additional thermal buffer-materials's calorific values were also considered to reduce the power plant's load. The results showed that the screening efficiency of MBT facility and the physical characteristics of each waste can be identified, and the calorific value by seasonal variation for MBT facility can be kept constant all the year round by using an additional thermal buffer-materials.

Impermeable Standards for the Concrete Bottom of Dikes for Crude Oil Storage Tanks (원유저장탱크 방류벽의 콘크리트 바닥재 불침투성 세부기준 연구)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.54-60
    • /
    • 2016
  • The bottom of dikes must be kept impermeable to control hazardous chemicals spilled from storage tanks. Currently, insufficient related chemical control laws lead to a possibility to spread through the bottom. Generally, due to the high cost of installation and periodical maintenance, many businesses prefer to install the bottom with general concrete. But, since the impermeability of concrete is dependent on the kind of materials and chemical reaction, all concrete cannot be considered as impermeable material. Thus, it is necessary to make the installation standards of the dike bottom clear in order to avoid the argument over the impermeability and prevent the chemical accident. This study has suggested the standards of impermeable concrete by conducting 7-day exposure test to crude oil with the pilot dikes. The results have showed that the standards have the better impermeable performance compared with the germany standard, which have been penetrated at the maximum penetration depth of 1.9 cm. This study is expected to contribute to both the risk reduction of penetrating into the bottom and the cost reduction of spending to make the bottom of dikes impermeable.

Analysis on the Risk of the Impermeable Concrete Bottom of Dikes for Nitric Acid Storage Tanks (질산 저장탱크 방류벽의 불침투성 콘크리트 바닥에 대한 위험성 평가)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.53-59
    • /
    • 2016
  • Considering the chemical reaction between concrete which is the raw material of the dike bottoms and hazardous chemicals, some chemicals can have negative effects on the impermeability of concrete dike bottoms. The impermeable standards for the concrete bottom of dikes have been made in the recent study, but the previous study was based on the exposure test to crude oil which is not corrosive and not related to the chemical reaction. It can be concluded that the test of crude oil can't represent all kinds of hazardous chemicals, especially highly corrosive chemicals. Meanwhile, this study has conducted the exposure test to nitric acid that is strongly corrosive and very hazardous. The results have showed that nitric acid has been penetrated at the maximum penetration depth of 2.9 cm for 7 days and the impermeable standards are better than the germany standard. Through this study with severe chemical, the scientific basis on the installation standards of all dike bottoms which are generally used in the industry has been obtained.

A Study on the Development of Self-Checklists for Small and Medium-Sized Chemical Industries (중소규모 화학업종을 위한 자율점검표 개발 연구)

  • Woo Sub Shim;Kyeong-Seok Oh
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.757-763
    • /
    • 2023
  • Major industrial accidents in which workers die due to fires or explosions while working at chemical substance handling workplaces continue to occur. Among the major industrial accidents that occurred between 2005 and 2021, the accident status by work situation and equipment was analyzed. Through analysis, it was confirmed that storage, reaction, and piping facilities were the main causes of the accident, and a self-checklist for each facility was developed. Verification was conducted through the supply and use groups to evaluate the suitability of the use, duties, and items of the self-checklist. The user group showed higher satisfaction than the supplier group for all three suitability of use, job, and item. In particular, since the inspection items of the self-checklist were organized around the cause of the accident derived through the analysis of actual accident cases, the satisfaction level was high in all groups. It is expected that the self-checklist developed through this study will be useful not only for large companies but also for small and medium-sized chemical industries that lack professional manpower.

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.

Low and Intermediate Level Radioactive Waste Certification Program Plan (중.저준위 방사성폐기물 인증 프로그램 계획)

  • Ahn Sum-Jin;Kim Tae-Kook;Lee Young-Hee;Kang Ill-Sik;Shon Jong-Sik;Hong Kwon-Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.187-195
    • /
    • 2006
  • The regulation for the low and intermediate level radioactive waste to be transferred to the disposal facility, recently revised, require that radioactive waste generators should set up waste certification program to verify the radioactive waste conform to the waste acceptance criteria(WAC) before disposal. The radioactive waste disposal facility, scheduled to be constructed in Korea, will institute WAC for the wastes to be transferred to the facility. This WAC is expected to compose of the requirements for the radiological characterization, physical and chemical characterization, physical/chemical restriction, prohibited item, packaging, identification, labeling, and documentation. For the compliance with this regulation, The radioactive waste generators should verify that the waste meet WAC through performance of the waste certification program and are responsible for handing in all the certification documents to the disposal facility. This waste certification program plan was set up as a preliminary program for the certification of radioactive waste generated in Korea Atomic Energy Research Institute (KAERI) and should be further revised until preparation of WAC by disposal agent.

  • PDF

Assessment of Water and Pollutant Mass Balance by Soil Amendment on Infiltration Trench (침투도랑 토양치환의 물순환 및 비점오염물질저감 효과 평가)

  • Jeon, Minsu;Choi, Hyeseon;Kang, Heeman;Kim, Lee-hyung
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.145-152
    • /
    • 2020
  • Highways are characterized by high non-point pollutant emissions due to high traffic volumes and sections that cause abrupt change in driving speed (i.e. rest stations, ticketing office, etc.). Most highways in Korea were constructed with layers that do not allow adequate infiltration. Moreover, non-point pollution reduction facilities were not commonly installed on domestic highways. This study was conducted to evaluate a facility treating highway runoff and develop a cost-effective design for infiltration facilities by using soil amendment techniques. Performing soil amendment increased the hydraulic retention time (HRT) and infiltration rate in the facility by approximately 30% and 20%, respectively. The facility's efficiency of removing non-point pollutants (Total Suspend Soiled (TSS), Chemical Oxygen Demand(COD), Biological Oxygen Demand(BOD), Total Nitrogen (TN) and Total Phosphorus, (TP) were also increased by 20%. Performing soil amendment on areas with low permeability can increase the infiltration rates by improving the storage volume capacity, HRT, and infiltration area. The application of infiltration facilities on areas with low permeability should comply with the guidelines presented in the Ministry of Environment's Standards for installation of non-point pollution reduction facilities. However, soil amendment may be necessary if the soil infiltration rate is less than 13 mm/hr.

Soil Dehydrogenase Activity and Microbial Biomass C in Croplands of JeJu Province (제주지역 농경지 이용유형별 토양 탈수소효소활성과 미생물체량)

  • Joa, Jae-Ho;Moon, Kyung-Hwan;Choi, Kyung-San;Kim, Seong-Cheol;Koh, Sang-Wook
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.2
    • /
    • pp.122-128
    • /
    • 2013
  • This study was carried out to evaluate the soil dehydrogenase activity and microbial biomass C with soil type and land use in cropland of JeJu region. Soil chemical properties, dehydrogenase activity, and microbial biomass C were analyzed after sampling from upland (50 sites), orchard (50 sites), paddy (30 sites), horticultural facility (30 sites) in March. Average pH values was at 6.3 in upland soil, however soil chemical properties showed a large spatial variations in both orchard and horticultural facility soil. The Zn and Cu contents increased by the continuous application of pig manure compost in some citrus orchard soil. Soil dehydrogenase activity and microbial biomass C were higher in non-volcanic ash than in volcanic ash soil regardless of land use type. Soil dehydrogenase activity was two to four times higher in upland than in the others. It was at 38.7 ug TPF $24^{h-1}g^{-1}$ in non-volcanic ash of upland soil. Microbial biomass C content was very high in horticultural facility soil and it showed at 216.8 $mg\;kg^{-1}$ in non-volcanic ash. Soil dehydrogenase activity showed a positive correlation with organic matter ($r^2$=0.59), Zn ($r^2$=0.65), and Cu ($r^2$=0.66) in non-volcanic ash horticultural facility soil. There was a negative correlation ($r^2$=0.57) between soil organic matter and dehydrogenase activity in volcanic ash upland soil.

Development on AR-Based Operator Training Simulator(OTS) for Chemical Process Capable of Multi-Collaboration (다중협업이 가능한 AR 기반 화학공정 운전원 교육 시뮬레이터(OTS-Simulator) 개발)

  • Lee, Jun-Seo;Ma, Byung-Chol;An, Su-Bin
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.1
    • /
    • pp.22-30
    • /
    • 2022
  • In order to prevent chemical accidents caused by human error, a chemical accident prevention and response training program using advanced technology was developed. After designing a virtual process based on the previously built pilot plant, chemical accident response contents were developed. A part of the pilot facility was remodeled for content realization and a remote control function was given. In addition, a DCS program that can control facilities in a virtual environment was developed, and chemical process operator training (OTS) that can finally respond to virtual chemical accidents was developed in conjunction with AR. Through this, trainees can build driving skills by directly operating the device, and by responding to virtual chemical accidents, they can develop emergency response capabilities. If the next-generation OTS like this study is widely distributed in the chemical industry, it is expected to greatly contribute to the prevention of chemical accidents caused by human error.

Advanced Treatment of Liquid Fertilizer from Livestock Night Soil Treatment Facility by Membrane Separation Processes (분리막 공정을 이용한 축산분뇨 처리장 액비의 고도처리)

  • Kim, Joo-Hye;Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.142-150
    • /
    • 2014
  • This paper is to develop the process suitable for the advanced treatment of liquid fertilizer from the livestock night soil treatment facility (biogas plant). Nanofiltration (NF) and reverse osmosis (RO) process was used, respectively, for the advanced treatment of liquid fertilizer. And membrane bioreactor (MBR) with and without biomedia were tested, respectively, for the pretreatment. It was found that almost T-N of the liquid fertilizer was composed of ammoniacal nitrogen. Transmembrane pressure of MBR with biomedia increased slowly during the operation time, while that of MBR without biomedia increased rapidly at the initial time. But there was no difference observed in the removal efficiencies of COD, T-N, and T-P irrespective of the dosage of biomedia. When the liquid fertilizer was pretreated by MBR with biomedia, the removal efficiencies of COD, T-N, and T-P were 99.8, 86.5%, and 99.8% by NF, and 99.9, 86.8%, and 99.8% by RO, respectively. Compared with the effluent quality standards of the livestock night soil treatment facility, the water quality treated by MBR and NF/RO process met the standard for COD and T-P, but exceeded the permitted standard for T-N. In order to meet the effluent quality standard for T-N, it is necessary to change the MBR operation cycle or to add the secondary treatment by NF/RO.