• Title/Summary/Keyword: chemical communication

Search Result 514, Processing Time 0.028 seconds

Analysis of Characteristic of Graphene Thin Film Transistor and Properties of Graphene using Copper Substrate (구리기판을 이용한 그래핀 박막 특성 및 그래핀을 이용한 트랜지스터의 특성 분석)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2127-2132
    • /
    • 2013
  • Graphene thin film was prepared on the copper foils by chemical deposition, and the characteristic of graphene depending on $H_2$ and CH4 gas flow rates was analyzed by the Raman spectra. The graphene formation was improved with increment of methan gas flow rates. The increment of hydrogen gas flow rate made high intensity of D($1350cm^{-1}$) and G($1580cm^{-1}$). The peak of D($1350cm^{-1}$) is related with the defects, and the 2D($2700cm^{-1}$) increased depending on the increment of amount of methan gas flow rate. The rate of G/2D indicates the quality of garphene to like a monolayer, and the small value of G/2D means better grapheme. The G/2D of graphene after annealed at $200^{\circ}C$ was 0.55 and improved the characteristic of graphene than the deposited-grapnene. Thin film transistor with graphene as an active channel was p-type semiconductor.

Effects of Orally-Administered Bifidobacterium animalis subsp. lactis Strain BB12 on Dextran Sodium Sulfate-Induced Colitis in Mice

  • Chae, Jung Min;Heo, Wan;Cho, Hyung Taek;Lee, Dong Hun;Kim, Jun Ho;Rhee, Min Suk;Park, Tae-Sik;Kim, Yong Ki;Lee, Jin Hyup;Kim, Young Jun
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.11
    • /
    • pp.1800-1805
    • /
    • 2018
  • Inflammatory bowel disease, including Crohn's disease and ulcerative colitis (UC), is a chronically relapsing inflammatory disorder of the gastrointestinal tract. Intestinal epithelial cells (IECs) constitute barrier surfaces and play a critical role in maintaining gut health. Dysregulated immune responses and destruction of IECs disrupt intestinal balance. Dextran sodium sulfate (DSS) is the most widely used chemical for inducing colitis in animals, and its treatment induces colonic inflammation, acute diarrhea, and shortening of the intestine, with clinical and histological similarity to human UC. Current treatments for this inflammatory disorder have poor tolerability and insufficient therapeutic efficacy, and thus, alternative therapeutic approaches are required. Recently, dietary supplements with probiotics have emerged as promising interventions by alleviating disturbances in the indigenous microflora in UC. Thus, we hypothesized that the probiotic Bifidobacterium animalis subsp. lactis strain BB12 could protect against the development of colitis in a DSS-induced mouse model of UC. In the present study, oral administration of BB12 markedly ameliorated DSS-induced colitis, accompanied by reduced tumor necrosis factor-${\alpha}$-mediated IEC apoptosis. These findings indicate that the probiotic strain BB12 can alleviate DSS-induced colitis and suggest a novel mechanism of communication between probiotic microorganisms and intestinal epithelia, which increases intestinal cell survival by modulating pro-apoptotic cytokine expression.

A SCADA Testbed Implementation Architecture for Security Assessment (SCADA 시스템의 보안성 평가를 위한 테스트베드 구성)

  • Lee, Jong-Joo;Kim, Seog-Joo;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.50-56
    • /
    • 2010
  • Supervisory Control and Data Acquisition Systems (SCADAs) is real-time monitor and control systems. SCADA systems are used to monitor or control chemical and transportation processes, in municipal water supply systems, electric power generation, transmission and distribution, gas and oil pipelines, and other distributed processes. SCADA refers to a large-scale distributed system. The supervisory control system is placed on top of a real time control system to control external processes. Emerging security technologies and security devices are decreasing the vulnerability of the power system against cyber threats. Dealing with these threats and analyzing vulnerabilities is an important task for equipment such as RTU, IED and FEP. To reduce such risks, we develop such a SCADA testbed. This paper presents the development of a testbed designed to assess the vulnerabilities SCADA networks(including serial communication).

Development of Real time distributed Object Remote Monitroing system (실시간 분산객체 원격 모니터링 시스템의 개발)

  • Moon, Myung-Ho;Koo, Kyung-Wan
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • As information communication technology developed we could monitor temperature, weather, indoor and outdoor status which we need to monitor using various sensors. Even further we could monitor our body such as Sa02 and serologic chemical tests easily at home or office. It is possible though interlocking the house medical instrument with the wireless public data network. Data from sensors can be transmitted to the distant control room and will be essentially applied through wireless public data network. In this study we measured various sensor data for the telemetry in one system. The sensing items are mainly focused on the static and dynamic behaviors of the bridge, building, instruments. The study suggests the transmit system model utilized by the wireless public data network. The suggestion in the study of telemetry system provides movement and preservation. And it will exam various condition in distance or at home.

  • PDF

Pattern of Pharmacist Consultation among the Health Counseling Services via Internet Portal Sites: A Pilot Study (국내 포털사이트에서의 지식검색서비스를 이용한 약사와의 상담 패턴에 대한 시험적 연구)

  • Kim, Heejin;Park, Jun Ha;Ji, Eunhee
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.4
    • /
    • pp.324-329
    • /
    • 2016
  • Background: With the development of information and communication technology, there is a growing number of people looking for health information on the internet. This pilot study was performed to analyze the pattern of pharmacist consultation on the internet portal site. Methods: Questions and answers posted on the portal site "Naver Jisik-iN" from March 1st to 31th in 2016 were collected. Medications asked were categorized into prescription drugs, nonprescription drugs, sanitary aids, emergency drugs, functional health foods, and others. Medications were subcategorized into 14 according to the anatomical therapeutic chemical classification system. Questions were divided into 10 categories based on Hepler's drug-related problems. Results: Of the 955 cases, females accounted for 59.5% and inquirers from 11 to 40 years old, 89.4%. The number of prescription drugs, nonprescription drugs, sanitary aids, emergency drugs, functional health foods, and others were 428 (44.8%), 328 (34.3%), 31 (3.3%), 2 (0.2%), 122 (12.8%), and 44 (4.6%), respectively. Questions for drugs acting on alimentary tract and metabolism took up 27.4% followed by those on nervous system, 13.6% and anti-infectives for systemic use, 12.2%. Pharmacist consultation regarding drug information, drug interaction, and adverse reaction occupied 47.9%, 15.2%, and 12.3%, respectively. Conclusion: Health counseling through online is predicted to increase steadily, so pharmacists should broaden their boundaries beyond off-line pharmacies to meet social needs.

Study on Lowering of the Polarization in SiOC Thin FIlms by Post Annealing (SiOC 박막에서 열처리에 의한 분극의 감쇄현상에 관한 연구)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1747-1752
    • /
    • 2012
  • The SiOC film of carbon centered system was prepared using bistrimethylsilylmethane (BTMSM) and oxygen mixed precursor by the chemical vapor deposition. The dielectric constant is measured by MIS(metal/insulator/Si) structure, but it could decrease the reliability because the uniformity is not assured. To research the dielectric constant of SiOC film, the range of low polarization was researched in SiOC film using the optical analysis and hardness, and then calculated the dielectric constant of SiOC film with amorphous structure of high degree. After annealing, the dielectric constant of SiOC film was decreased owing to the lowering of polarization, and FTIR spectra of the main bond was shifted to higher wave number. The main bond of 950~1200 cm-1 was composed of the Si-C and Si-O bonds. The intensity increases in Si-O bond infers the bonding strength became stronger than that of deposited film. Annealed SiOC film showed 2.06 in dielectric constant.

Predictive Control for Mobile Robots Using Genetic Algorithms (유전알고리즘을 이용한 이동로봇의 예측제어)

  • Son, Hyun-sik;Park, Jin-hyun;Choi, Young-kiu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.4
    • /
    • pp.698-707
    • /
    • 2017
  • This paper deals with predictive control methods of mobile robots for reference trajectory tracking control. Predictive control methods using predictive model are known as effective schemes that minimize the future errors between the reference trajectories and system states; however, the amount of real-time computation for the predictive control are huge so that their applications were limited to slow dynamic systems such as chemical processing plants. Lately with high computing power due to advanced computer technologies, the predictive control methods have been applied to fast systems such as mobile robots. These predictive controllers have some control parameters related to control performance. But these parameters have not been optimized. In this paper we employed the genetic algorithm to optimize the control parameters of the predictive controller for mobile robots. The improved performances of the proposed control method are demonstrated by the computer simulation studies.

A Study on the Hermetic Method for Packaging of Implantable Medical Device (생체 이식형 의료기기의 패키징을 위한 완전 밀폐 방법에 관한 연구)

  • Park, Jae-Soon;Kim, Sung-Il;Kim, Eung-Bo;Kang, Young-Hwan;Cho, Sung-Hwan;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.407-412
    • /
    • 2017
  • This paper introduces a biocompatible packaging system for implantable medical device having a hermetic sealing, such that a perfect physical and chemical isolation between electronic medical system and human body (including tissue, body fluids, etc.) is obtained. The hermetic packaging includes an electronic MEMS pressure sensor, power charging system, and bluetooth communication system to wirelessly measure variation of capacitance. The packaging was acquired by Quartz direct bonding and $CO_2$ laser welding, with a size of width $ 6cm{\times}length\;10cm{\times}lheight\;3cm$. Hermetic sealing of the packaged system was tested by changing the pressure in a hermetic chamber using a precision pressure controller, from atmospheric to 900 mmHg. We found that the packaged system retained the same count or capacitance values with sensor 1 - 25,500, sensor 2 - 26,000, and sensor 3 - 20,800, at atmospheric as well as 900 mmHg pressure for 5 hours. This result shows that the packaging method has perfect hermetic sealing in any environment of the human body pressure.

System Development and Management for Underachieved Students (자존감 향상 프로그램 개발 및 운영사례)

  • Kim, Young-Jun;Kim, Hee-Kyo;Oh, Kyeong-seok
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.183-190
    • /
    • 2018
  • With decreasing the number of high school graduates, it is vital for each college to maintain its enrollment number as well as to preserve its dropout rate in a lower level. It is true that all universities and colleges have experienced inevitable dropouts that were in fact more serious in 2 to 3-year colleges. There have been prior studies to examine what factors affected to students' dropout in various ways. However, no specific programs were employed to mitigate the rates of dropout. In this study, new encouraging program is introduced for the students who were not ready to study and isolated from classroom. The result showed that the program led to the GPA enhancement in larger number of participants. Nevertheless, the sustainablity of the program would be unclear unless it combines with other existing programs.

Development of Real time Air Quality Prediction System

  • Oh, Jai-Ho;Kim, Tae-Kook;Park, Hung-Mok;Kim, Young-Tae
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.73-78
    • /
    • 2003
  • In this research, we implement Realtime Air Diffusion Prediction System which is a parallel Fortran model running on distributed-memory parallel computers. The system is designed for air diffusion simulations with four-dimensional data assimilation. For regional air quality forecasting a series of dynamic downscaling technique is adopted using the NCAR/Penn. State MM5 model which is an atmospheric model. The realtime initial data have been provided daily from the KMA (Korean Meteorological Administration) global spectral model output. It takes huge resources of computation to get 24 hour air quality forecast with this four step dynamic downscaling (27km, 9km, 3km, and lkm). Parallel implementation of the realtime system is imperative to achieve increased throughput since the realtime system have to be performed which correct timing behavior and the sequential code requires a large amount of CPU time for typical simulations. The parallel system uses MPI (Message Passing Interface), a standard library to support high-level routines for message passing. We validate the parallel model by comparing it with the sequential model. For realtime running, we implement a cluster computer which is a distributed-memory parallel computer that links high-performance PCs with high-speed interconnection networks. We use 32 2-CPU nodes and a Myrinet network for the cluster. Since cluster computers more cost effective than conventional distributed parallel computers, we can build a dedicated realtime computer. The system also includes web based Gill (Graphic User Interface) for convenient system management and performance monitoring so that end-users can restart the system easily when the system faults. Performance of the parallel model is analyzed by comparing its execution time with the sequential model, and by calculating communication overhead and load imbalance, which are common problems in parallel processing. Performance analysis is carried out on our cluster which has 32 2-CPU nodes.

  • PDF