Browse > Article
http://dx.doi.org/10.4313/JKEM.2017.30.7.407

A Study on the Hermetic Method for Packaging of Implantable Medical Device  

Park, Jae-Soon (Department of Electronics and Control Engineering, Hanbat National University)
Kim, Sung-Il (Department of Electronics and Control Engineering, Hanbat National University)
Kim, Eung-Bo (Department of Electronics and Control Engineering, Hanbat National University)
Kang, Young-Hwan (Department of Electronics and Control Engineering, Hanbat National University)
Cho, Sung-Hwan (Department of Electronics and Control Engineering, Hanbat National University)
Joung, Yeun-Ho (Department of Electronics and Control Engineering, Hanbat National University)
Publication Information
Journal of the Korean Institute of Electrical and Electronic Material Engineers / v.30, no.7, 2017 , pp. 407-412 More about this Journal
Abstract
This paper introduces a biocompatible packaging system for implantable medical device having a hermetic sealing, such that a perfect physical and chemical isolation between electronic medical system and human body (including tissue, body fluids, etc.) is obtained. The hermetic packaging includes an electronic MEMS pressure sensor, power charging system, and bluetooth communication system to wirelessly measure variation of capacitance. The packaging was acquired by Quartz direct bonding and $CO_2$ laser welding, with a size of width $ 6cm{\times}length\;10cm{\times}lheight\;3cm$. Hermetic sealing of the packaged system was tested by changing the pressure in a hermetic chamber using a precision pressure controller, from atmospheric to 900 mmHg. We found that the packaged system retained the same count or capacitance values with sensor 1 - 25,500, sensor 2 - 26,000, and sensor 3 - 20,800, at atmospheric as well as 900 mmHg pressure for 5 hours. This result shows that the packaging method has perfect hermetic sealing in any environment of the human body pressure.
Keywords
Hermetic packaging; Pressure sensor; MEMS; Quartz; Wireless;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 S. I. Kim, Ph. D. Development of Implantable Pressure Sensor Using MEMS Process and Quartz Wafer Direct Bonding, p. 2-5, Hanbat National University, Daejeon (2015).
2 M. A. Fonseca, Polymer/Ceramic Wireless MEMS Pressure Sensors for Harsh Environment, p. 6-12, Georgia Institute of Technology, Atlanta (2007).
3 Siemens, MSDS (ProC global), http://175.126.111.63:8080/msds/hemostasis/ProC_Global.pdf (2009).
4 J. T. Kim, S. I. Kim, and Y. H. Joung, J. Korean Inst. Electr. Electron. Mater. Eng., 26, 669 (2013). [DOI: http://dx.doi.org/10.4313/JKEM.2013.26.9.669]   DOI
5 S. J. Myung, T. H. Lee, K. C. Huh, S. C. Choi, and C. I. Sohn, Korean J. Gastroenterol., 55, 316 (2010). [DOI: https://doi.org/10.4166/kjg.2010.55.5.316]   DOI