• Title/Summary/Keyword: centralized control

Search Result 390, Processing Time 0.025 seconds

Evaluation of Power Flow Control Strategy and DC-link Voltage Regulation for DC Microgrid

  • Nguyen, Thanh Van;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.416-417
    • /
    • 2019
  • In this paper, an effective power flow control strategy (PFCS) based on the centralized control approach and a DC-link (DCV) restoration algorithm for DC microgrid (DCMG) are presented. By investigating the statuses of system power units, eleven operating modes are given to ensure the system power balance under various conditions. To avoid the system power imbalance caused by the delay of grid fault detection, a reliable DCV restoration algorithm is proposed. In the proposed scheme, when an abnormal variation of the DCV is detected, the battery instantly starts a local emergency control mode to restore the DCV to the nominal value regardless of the control mode from the central controller. The simulations and experiments are carried out to prove the effectiveness of the PFCS and the proposed DCV restoration algorithm.

  • PDF

Low-Voltage-Stress AC-Linked Charge Equalizing System for Series-Connected VRLA Battery Strings

  • Karnjanapiboon, Charnyut;Jirasereeamornkul, Kamon;Monyakul, Veerapol
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.186-196
    • /
    • 2013
  • This paper presents a low voltage-stress AC-linked charge equalizing system for balancing the energy in a serially connected, valve-regulated lead acid battery string using a modular converter that consists of multiple transformers coupled together. Each converter was coupled through an AC-linked bus to increase the overall energy transfer efficiency of the system and to eliminate the problem of the unbalanced charging of batteries. Previous solutions are based on centralized and modularized topologies. A centralized topology requires a redesign of the hardware and related components. It also faces a high voltage stress when the number of batteries is expanded. Modularized solutions use low-voltage-stress, double-stage, DC-linked topologies which leads to poor energy transfer efficiency. The proposed solution uses a low-voltage stress, AC-linked, modularized topology that makes adding more batteries easier. It also has a better energy transfer efficiency. To ensure that the charge equalization system operates smoothly and safely charges batteries, a small intelligent microcontroller was used in the control section. The efficiency of this charge equalization system is 85%, which is 21% better than other low-voltage-stress DC-linked charging techniques. The validity of this approach was confirmed by experimental results.

An Efficient Network Management System using The Smart Router (스마트 라우터를 사용한 효율적인 네트워크 관리 시스템)

  • Park Moon-Hwa
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.253-260
    • /
    • 2005
  • Active networks not only allows the network nodes, switches or routers. to perform routing and forwarding but so allows their users inject customized programs into the nodes of the network or the packets. that may modify, store or redirect the user data flowing through the network. In this paper, we proposed a new network management system built using active network technology, that can solve problems inherent in most of existing legacy centralized network management systems. The main contribution is to present the Smart Router model that can reduce traffics due to managing networks by way of making control packets into simplified patterns. The disadvantages of the centralized network management are presented and the current solution for distributed network management are discussed. The performance improvements that our architecture offers are showed through a service example experiment.

  • PDF

Two-Tier Interference Elimination for Femtocells Based on Cognitive Radio Centralized Spectrum Management

  • Yi, Leng-Gan;Lu, Yi-Min
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.5
    • /
    • pp.1514-1531
    • /
    • 2014
  • Femtocell provides better coverage and higher spectrum efficiency in areas rarely covered by macrocells. However, serious two-tier interference emerging from randomly deploying femtocells may create dead zones where the service is unavailable for macro-users. In this paper, we present adopting cognitive radio spectrum overlay to avoid intra-tier interference and incorporating spectrum underlay and overlay to coordinate cross-tier interference. It is a novel centralized control strategy appropriate for both uplink and downlink transmission. We introduce the application of proper spectrum sharing strategy plus optimal power allocation to address the issue of OFDM-based femtocells interference-limited downlink transmission, along with, a low-complexity suboptimal solution proposed. Simulation results illustrate the proposed optimal scheme achieves the highest transmission rate on successfully avoiding two-tier interference, and outperforms the traditional spectrum underlay or spectrum overlay, via maximizing the opportunity to transmit. Moreover, the strength of our proposed schemes is further demonstrated by comparison with previous classic power allocation methods, in terms of transmission rate, computational complexity and signal peak-to-average power ratio.

Design and implementation of centralized collaborative works through the service node on the NISDN (서비스노드를 통한 협대역 ISDN에서의 중앙 집중형 공동작업 기능 설계 및 구현)

  • 이강필;황성호;김태규;조규섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.3
    • /
    • pp.643-651
    • /
    • 1996
  • In this paper, to provide the possibility of various multimedia services, especially the collaborative work using the centralized control feature of the Service Node, is studied. We focused on the telewriting as the upper layer application to confirm the basic functions of the collaborative work. For this, we implement and add telewriting collaborative work function to the Service Node emulator, and terminals operating in the Windows environment are also developed. Through the tests on the system, we verify the basic functions related to the collaborative work are performed adequately, and confirm the concept of Service Node can support various type of multimedia conference services.

  • PDF

Centralized Downlink Scheduling using Directional Antennas in IEEE 802.16 based Wireless Mesh Networks (IEEE 802.16 기반의 무선 메쉬 네트워크에서 지향성 안테나를 사용하는 중앙 집중형 하향링크 스케줄링)

  • Lee, Sang-Joon;Lee, Hyong-Woo;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.134-141
    • /
    • 2010
  • In this paper, we propose a scheduling algorithm to improve the performance of IEEE 802.16 based wireless mesh networks using directional antenna. The performance is presented in terms of throughput of system and delay between each node by varying number of users. The result show that proposed scheduling algorithm improving the performance by reducing the delay of mesh network system. Our work may be useful as a guideline to control the fairness between SSs for multi-hop systems such as multi-hop relay and mesh networks.

Toward manageable middleboxes in software-defined networking

  • Zadkhosh, Ehsan;Bahramgiri, Hossein;Sabaei, Masoud
    • ETRI Journal
    • /
    • v.42 no.2
    • /
    • pp.186-195
    • /
    • 2020
  • Software-defined networking (SDN) acts as a centralized management unit, especially in a network with devices that operate under the transport layer of the OSI model. However, when a network with layer 7 middleboxes (MBs) is considered, current SDNs exhibit limitations. As such, to achieve a real-centralized management unit, a new architecture is required that decouples the data and control planes of all network devices. In this report, we propose such a complementary architecture to the current SDN in which SDN-enabled MBs are included along with contemporary SDN-enabled switches. The management unit of this architecture improves network performance and reduces routing cost by considering the status of the MBs during flow forwarding. This unit consists of the following two parts: an SDN controller (SDNC) and a middlebox controller (MBC). The latter selects the best MBs for each flow and the former determines the best path according to its routing algorithm and provides information via the MBC. The results show that the proposed architecture improved performance because the utilization of all network devices including MBs is manageable.

Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building (외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF

Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building (초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

Decentralized Control of Building Structures Installed with Semi-active MR Damper (준능동 MR 댐퍼가 설치된 건축 구조물의 분산제어)

  • Youn, Kyung-Jo;Lee, Sang-Hyun;Min, Kyung-Won;Lee, Sung-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.127-132
    • /
    • 2007
  • In this paper, to overcome local damages of structures, an uncertainty of structural model, installing sensors of structures, and economics of building system, decentralized semi-active magnetorheological(MR) damper using the displacement or velocity transferred to the response of floor installed damper is proposed. Relative magnitude between the control force of dampers and the story shear force is difined as design variables and the performance indices response spectra analysis through nonlinear time history analysis excited by seismic loads is performed according to this design variables. And the performance of this decentralized MR damper is compared with previous centralized LQR control algorithm using 3-stories benchmark building structure excited by El Centro (1940, N.S) in order to evaluate the application of building structures.

  • PDF