• 제목/요약/키워드: center diaphragm method

검색결과 31건 처리시간 0.023초

보상용 브릿지를 이용한 압저항형 압력센서의 온도보상 방법 (Temperature compensation method of piezoresistive pressure sensor using compensating bridge)

  • 손원소;이재곤;최시영
    • 전자공학회논문지D
    • /
    • 제35D권5호
    • /
    • pp.63-68
    • /
    • 1998
  • The absolute pressure sensor using SDB wafer has been fabricated. the structure of the sensor consists of two wheatstone bridges and a diaphragm. One of the two wheatstone bridges is located on the edge of diaphragm, and the other is located on the center of diaphragm. The diaphragm cavity is sealted in vacuum (~10$^{5}$ Torr) to reduce the effect of temperature due to the vapor in the cavity on the sensitivity of pressure sensor. This is the minor method of temperature compensation method. In this experiment the main compensation method is to use the difference of the two bridge offset voltages. The drift of offset voltage with temperature is reduced by using this method so that temperature charcteristics is improved. In this method the temperature effect in the range of 22~100.deg. C was compensated over 80%.

  • PDF

Radiologic assessment of the optimal point for tube thoracostomy using the sternum as a landmark: a computed tomography-based analysis

  • Jaeik Jang;Jae-Hyug Woo;Mina Lee;Woo Sung Choi;Yong Su Lim;Jin Seong Cho;Jae Ho Jang;Jea Yeon Choi;Sung Youl Hyun
    • Journal of Trauma and Injury
    • /
    • 제37권1호
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose: This study aimed at developing a novel tube thoracostomy technique using the sternum, a fixed anatomical structure, as an indicator to reduce the possibility of incorrect chest tube positioning and complications in patients with chest trauma. Methods: This retrospective study analyzed the data of 184 patients with chest trauma who were aged ≥18 years, visited a single regional trauma center in Korea between April and June 2022, and underwent chest computed tomography (CT) with their arms down. The conventional gold standard, 5th intercostal space (ICS) method, was compared to the lower 1/2, 1/3, and 1/4 of the sternum method by analyzing CT images. Results: When virtual tube thoracostomy routes were drawn at the mid-axillary line at the 5th ICS level, 150 patients (81.5%) on the right side and 179 patients (97.3%) on the left did not pass the diaphragm. However, at the lower 1/2 of the sternum level, 171 patients (92.9%, P<0.001) on the right and 182 patients (98.9%, P= 0.250) on the left did not pass the diaphragm. At the 5th ICS level, 129 patients (70.1%) on the right and 156 patients (84.8%) on the left were located in the safety zone and did not pass the diaphragm. Alternatively, at the lower 1/2, 1/3, and 1/4 of the sternum level, 139 (75.5%, P=0.185), 49 (26.6%, P<0.001), and 10 (5.4%, P<0.001), respectively, on the right, and 146 (79.3%, P=0.041), 69 (37.5%, P<0.001), and 16 (8.7%, P<0.001) on the left were located in the safety zone and did not pass the diaphragm. Compared to the conventional 5th ICS method, the sternum 1/2 method had a safety zone prediction sensitivity of 90.0% to 90.7%, and 97.3% to 100% sensitivity for not passing the diaphragm. Conclusions: Using the sternum length as a tube thoracostomy indicator might be feasible.

전단응력형 집적화 압력센서의 최적설계 (The study on optimum design for shear stress integrated pressure sensor)

  • 주리아;도태성;이종녕;서희돈
    • 전자공학회논문지T
    • /
    • 제35T권1호
    • /
    • pp.75-81
    • /
    • 1998
  • 본 논문은 장방형 다이아프램 형상과 단일형 피에조저항 전단응력 스트레인 게이지 와의 관계를 해석하여 최적의 전단응력 압력센서를 설계하기 위한 것이다. 다이아프램상의 전단응력을 시뮬레이션 하기 위하여 유한요소법 분석 프로그램 ANSYS 5.1를 사용하였다. 시뮬레이션 결과는 다이아프램 형상비가 3일때 스트레인 게이지의 위치는 중앙에서, 크기는 전체 장방형 다이아프램 크기의 8%를 점유할때 온도에 안정적이고, 최대 감도를 가진다는 것을 조사하였다.

  • PDF

초고압 압력센서용 다이어프램 설계 및 PZT 구동 변형시험기를 이용한 성능평가 (Design of Diaphragm for Ultra High Pressure Sensors and Its performance Evaluation Using a PZT Actuated Deformation Tester)

  • 윤대중;안중환
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.58-63
    • /
    • 2019
  • This research aims at designing a diaphragm made of SUS316L stainless steel for ultra high pressure sensors and evaluating its performance with a PZT driven deformation tester instead of high pressure chamber testing up to 100 MPa. Finite element method analysis indicates that the optimum thickness of a flat diaphragm is 1.5 mm not only to secure safety of sensors up to 100 MPa but also to enhance displacement measuring sensitivity. For this thickness, the maximum displacement at the center of the diaphragm is $5.3{\mu}m$. The PZT actuator must offer a force of 1,669 N to create a pressure of 100 MPa at the diaphragm surface in order to obtain a displacement of $5.3{\mu}m$. The performance evaluation by the PZT driven tester demonstrates nearly the same results as the same results as the sensors tested in the ultra high pressure chamber.

정적법을 이용한 중진공 국가표준기 개발 (Development of a national medium vacuum standard by static expansion method)

  • 홍승수;임인태;신용현;정광화
    • 한국진공학회지
    • /
    • 제14권2호
    • /
    • pp.59-68
    • /
    • 2005
  • 부피가 다른 세 개의 진공용기를 조합하여 정적법 (static expansion method)을 이용한 중진공영역의 국가표준기를 개발하였다. 이 장치를 이용하여 133pa 범위의 용량형 진공게이지 (capacitance diaphragm gauge)를 교정하여 국제표준화기구의 측정불확도 표현지침에 따라 분석하였다. 그 결과 표준압력 0.553Pa에서의 확장불확도 (expanded uncertainty)가 95% 신뢰수준 (confidence level), 포함인자 (coverage factor) k=2에서 $2.628\times10^{-3}Pa$로 우수한 성능을 보였다.

스피커 진동판의 음향특성 다분야통합최적설계 (Multidisciplinary Design Optimization for Acoustic Characteristics of a Speaker Diaphragm)

  • 김성국;이태희;이석순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.763-766
    • /
    • 2004
  • Recently, various acoustic artifacts that contains speaker have been produced such as cellular phone. Speaker consists of diaphragm generating sound and coil vibrating diaphragm. Generally, good speaker means that it has a wide frequency range, high output power rate to input power and flat sound pressure level in specified frequency range. Acoustic characteristic was estimated through the experiment and computer simulation, or sound power was controlled with acoustic sensitivity in a natural frequency range fer last decade. However, the flatness of sound pressure level has not been considered to enhance the sound quality of a speaker. Tn this study, a method for speaker design is proposed for a good acoustic characteristic, which is flatness of SPL(sound pressure level) and wideness between the first and second natural frequency. SYSNOISE is used fer acoustic analysis and ANSYS is used for harmonic response analysis and modal analysis. Optimization for acoustic characteristics of a speaker diaphragm is performed using ModelCenter. All analyses are done within a frequency domain. And we confirm that the experimental and computational simulations have similar trend.

  • PDF

초음파간섭 수은주압력계와 정적법 중진공 국가표준기 상호비교 (Inter-comparison between ultrasonic interferometer manometer and medium vacuum standards by static expansion method)

  • 홍승수;임인태;신용현;정광화
    • 한국진공학회지
    • /
    • 제14권3호
    • /
    • pp.103-109
    • /
    • 2005
  • 정적법을 이용하여 새로운 중진공 국가표준기를 개발하였다. 이 장치의 성능평가를 위해 측정범위가 각각 133pa과 1,333pa인 두 개의 용량혈 진공게이지를 전달표준기로 사용하여 초음파간섭 수은주압력계와 중진공 표준을 상호비교하였다. Error normalized (En) 값으로 분석한 결과 교정압력 $3pa\;\sim\;100pa$에서 두 표준기는 합성불확도 범위 내에서 잘 일치하고 있음을 알 수 있었다.

Improving cyclic behavior of multi-level pipe damper using infill or slit diaphragm inside inner pipe

  • Zahrai, Seyed Mehdi;Cheraghi, Abdullah
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.195-204
    • /
    • 2017
  • Analytical and experimental studies of the innovative pipe in pipe damper have been recently investigated by the authors. In this paper, by adding lead or zinc infill or slit diaphragm inside the inner pipe, it is tried to increase the equivalent viscous damping ratio improving the cyclic performance of the recently proposed multi-level control system. The damper consists of three main parts including the outer pipe, inner pipe and added complementary damping part. At first plastic deformations of the external pipe, then the internal pipe and particularly the added core and friction between them make the excellent multi-level damper act as an improved energy dissipation system. Several kinds of added lead or zinc infill and also different shapes of slit diaphragms are modeled inside the inner pipe and their effectiveness on hysteresis curves are investigated with nonlinear static analyses using finite element method by ABAQUS software. Results show that adding lead infill has no major effect on the damper stiffness while zinc infill and slit diaphragm increase damper stiffness sharply up to more than 10 times depending on the plate thickness and pipe diameter. Besides, metal infill increases the viscous damping ratio of dual damper ranging 6-9%. In addition, obtained hysteresis curves show that the multi-level control system as expected can reliably dissipate energy in different imposed energy levels.

깊은호흡 시 미주신경 전기자극이 호흡근 활성과 호흡능력에 미치는 효과(사례 연구) (Effect of Vagus Nerve Electrical Stimulation on Respiratory Muscle Activity and Lung Capacity during Deep Breathing (Case Study))

  • 문현주
    • 대한통합의학회지
    • /
    • 제7권2호
    • /
    • pp.181-187
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the activity of respiratory muscle and lung capacity during deep breathing with electrical stimulation of the vagus nerve. Methods: This study was conducted on 30 healthy adults in their 20s. Subjects were randomly performed to deep breathing or deep breathing with vagus nerve electrical stimulation. All subjects' diaphragm and internal oblique muscle activity were measured during deep breathing by electromyography, and lung capacity was measured by spirometry immediately after beep breathing. In the vagus nerve stimulation method, the surface electrode was cut into the left ear and then electrically stimulated using a needle electric stimulator. Results: The activity of diaphragm was significantly increased in deep breathing with vagus nerve electrical stimulation than in deep breathing. However, lung capacity did not show any significant difference according to the condition. Conclusion: Vagus nerve electrical stimulation could induce diaphragm activity more than deep breathing alone. Deep breathing with vagus nerve electrical stimulation may enhance the activity of the respiratory muscles and is expected to be an effective treatment for the elderly or COPD patients with poor breathing ability.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.