• Title/Summary/Keyword: cements

Search Result 570, Processing Time 0.026 seconds

Estimation of Bituminous Concrete Property Based on Molecular Size Distribution of Asphalt Cement (아스팔트 시멘트의 분자립도 분포특성에 따른 아스팔트의 성질분석)

  • 김광우;연규석
    • Magazine of the Korea Concrete Institute
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 1991
  • Moleclar size distribution of three AC-20 asphalt cements were observed using high pressure - gel permeation chromatograph (HP-GPC). Bituminous concrete specimens were made using the asphalt cements and one aggre¬gate in laboratory to measure mechanical properties, tensile strength CIS) and resilient modulusCM,J. in dry and wet conditons. Results of mechanical property tests and profile of molecular size distribution of asphalt cements were analyzed to evaluate the relatonship of mechanical property with chromatogram. Regression analy¬sis showed a strong correlation between a mechanical property and sliced percent areas of chromatogram. Mathematical prediction models were developed based on the regression analysis. It was shown that characteris¬tics of asphalt cement chromatogram could be successfully used for estimation of selected mechanical property of asphalt concrete .

Effects of compatibility between PNS Superplasticzer and soluble alkali of cements on performances of concrete (PNS계 고성능 감수제와 시멘트 수용성 알칼리양과의 상용성이 콘크리트 물성에 미치는 영향)

  • Ahn, Tae-ho;Park, Junhui;Sho, Kwangho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.4
    • /
    • pp.173-177
    • /
    • 2017
  • A polynaphthalenesulfonate (PNS) superplasticizer and its relation to the fluidity of cement paste (w/c = 0.35) has been investigated for three cements at a given dosage of PNS superplasticizer. Chemical properties of three cements were characterized with a XRD, XRF. The additive effects of $Na_2SO_4$ on the fresh concrete with w/c = 0.33 were also estimated by the measurement of compressive strength, slump, air content. The experimental results exhibited that the addition of sodium sulfate 2.6 % to the cement A and C improves slump loss. In case of cement E, the addition of sodium sulfate 1.3 % was effective.

The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer (X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석)

  • Jung, Ji Eun;Jang, Yu Rim;Kim, Ki-Wook;Heo, Sangcheol;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

Magnesium potassium phosphate cements to immobilize radioactive concrete wastes generated by decommissioning of nuclear power plants

  • Pyo, Jae-Young;Um, Wooyong;Heo, Jong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2261-2267
    • /
    • 2021
  • This paper evaluates the efficacy of magnesium potassium phosphate cements (MKPCs) as waste forms for the solidification of radioactive concrete powder wastes produced by the decommissioning of nuclear power plants. MKPC specimens that contained up to 50 wt% of simulated concrete powder wastes (SCPWs) were evaluated. We measured the porosity and compressive strength of the MKPC specimens, observing them using scanning electron microscopy and X-ray diffraction. The addition of SCPWs reduced the porosity and increased the compressive strength of the MKPC specimens. Struvite-K crystals were well-synthesized, and no additional crystal phase was formed. After thermal cycling and after immersion, MKPC specimens with 50 wt% SCPWs satisfied the waste-acceptance criteria (WAC) for compressive strength. Semi-dynamic leaching tests were performed using the ANS 16.1 method; the leachability indices of Cs, Co, and Sr were 11.45, 17.63, and 15.66, respectively, which also satisfy the WAC. Thus, MKPCs can provide stable matrices to immobilize radioactive concrete wastes generated by the decommissioning of nuclear power plants.

Effects of calcium silicate cements on neuronal conductivity

  • Derya Deniz-Sungur;Mehmet Ali Onur;Esin Akbay;Gamze Tan;Fugen Dagli-Comert;Taner Cem Sayin
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.18.1-18.9
    • /
    • 2022
  • Objectives: This study evaluated alterations in neuronal conductivity related to calcium silicate cements (CSCs) by investigating compound action potentials (cAPs) in rat sciatic nerves. Materials and Methods: Sciatic nerves were placed in a Tyrode bath and cAPs were recorded before, during, and after the application of test materials for 60-minute control, application, and recovery measurements, respectively. Freshly prepared ProRoot MTA, MTA Angelus, Biodentine, Endosequence RRM-Putty, BioAggregate, and RetroMTA were directly applied onto the nerves. Biopac LabPro version 3.7 was used to record and analyze cAPs. The data were statistically analyzed. Results: None of the CSCs totally blocked cAPs. RetroMTA, Biodentine, and MTA Angelus caused no significant alteration in cAPs (p > 0.05). Significantly lower cAPs were observed in recovery measurements for BioAggregate than in the control condition (p < 0.05). ProRoot MTA significantly but transiently reduced cAPs in the application period compared to the control period (p < 0.05). Endosequence RRM-Putty significantly reduced cAPs. Conclusions: Various CSCs may alter cAPs to some extent, but none of the CSCs irreversibly blocked them. The usage of fast-setting CSCs during apexification or regeneration of immature teeth seems safer than slow-setting CSCs due to their more favorable neuronal effects.

Bone Cements in TTCP, DCPA, β-TCP and PHA System (TTCP-DCPA-β-TCP-PHA계 골 시멘트)

  • ;;;Rainer Telle
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.57-67
    • /
    • 2002
  • The effect of $\beta$-TCP and PHA as additives on initial setting time, compressive strength and surface micro-structure after in vitro test of bone cement in TTCP and DCPA system was investigated. The median particle sizes of TTCP, $\beta$-TCP, DCPA and PHA for bone cement were about 3, 5, 0.9 and 4${\mu}{\textrm}{m}$, respectively. Initial setting time and compressive strength of bone cement with various composition was measured by Vicat test and Universal Testing Machine, and surface morphology and crystalline phases of bone cements were observed and analyzed by SEM and x-ray diffractometer. Initial setting time was not affected by composition but by powder/liquid ratio, and cement with PHA required double amount of solution for paste as much as one without PHA, especially. It was thought that $\beta$-TCP and PHA in bone cements was not related to setting reaction. Thus, the addition of $\beta$-TCP and PHA in bone cements decreased compressive strength and inhabited HAP from being produced on surface in vitro test. In conclusion, it was not expected that $\beta$-TCP and PHA in TTCP-DCPD bone cements enhanced the strength and bioacitivity.

In vitro cytotoxicity of four kinds orthodontic band cements (수종 치과 교정용 밴드 시멘트의 세포독성에 관한 실험적 연구)

  • Lee, Won-Chul;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.351-362
    • /
    • 2004
  • Orthodontic band cements are widely used in the fields of orthodontics, but they are commonly known as cytotoxic material. Within an oral cavity several ions and components are released from orthodontic band cements, thus causing inflammation or injury to the Periodontal tissue. Therefore, it is very important to estimate the biocompatibility of orthodontic band cements. The purpose of this study was to assess the cytotoxic effect of orthodontic band cements to HGF cells. A zinc phosphate cement, a glass ionomer, a resin modified glass ionomer, and compomer were used to evaluate three cytotoxicity assays: cell proliferation assay, MTT assay, and agar ovelay assay The results were as follows: 1. In the cell proliferation assay, Gl>ZPC, RMGI, RMGI24, GI24>compomer24, ZPC24, compomer>metal ring lined up in order of cytotoxicity 2. In the MTT assay, GI>ZPC, RMGI>GI24>ZPC24, compomer, metal ring, RMGI24, compomer24 lined up in order of cytotoxicity. 3. In the agar overlay test, GI>GI24, ZPC, ZPC24, RMGI>RMGI24, compomer, compomer24, metal ring lined up in order of cytotoxicity.

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF

THE EFFECT OF ACID ETCHING ON GLASS IONOMER CEMENT SURFACES (Glass ionomer cement 표면의 산부식 효과에 관한 연구)

  • Han, Seung-Weon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.1-26
    • /
    • 1993
  • The purpose of this study was to investigate the effect of acid etching on the surface appearance and fracture toughness of five glass ionomer cements. Five kinds of commercially available glass ionomer cements including chemical curing filling type, chemical curing lining type, chemical curing metal reinforced type, light curing tilling type and light curing lining type were used for this study. The specimens for SEM study were fabricated by treating each glass ionomer cement with either visible light curing or self curing after being inserted into a rubber mold (diameter 4mm, depth 1mm). Some of the specimens were etched with 37% phosphoric acid for 0, 15, 30, 60, go seconds, at 5 minutes, 1 hour and 1 day after mixing of powder and liquid. Unetched ones comprised the control group and the others were the experimental groups. The surface texture was examined by using scanning electron microscope at 20 kV. (S-2300, Hitachi Co., Japan). The specimens for fracture toughness were fabricated by curing of each glass ionomer cement previously inserted into a metal mold for the single edge notch specimen according to the ASTME399. They were subjected to a three-point bend test after etching for 0, 30, 60, and 90 seconds at 5 minutes-, 1 hour-and 1 day-lapse after the fabrication of the specimens. The plane strain fracture toughness ($K_{IC}$) was determined by three-point bend test which was conducted with cross-head speed of 0.5 mm/min using Instron universal testing machine (Model No. 1122) following seven days storage of the etched specimens under $37^{\circ}C$, 100% humidity condition. Following conclusions were drawn. 1. In unetched control group, crack was present, but the surface was generally smooth. 2. Deterioration of the surface appearance such as serious dissolving of gel matrix and loss of glass particles occured as the etching time was increased beyond 15 s following Immediate etching of chemical curing type of glass ionomer cements. 3. Etching after 1 h, and 1 d reduced surface damage, 15 s, and 30s etch gave rough surface appearance without loss of glass particle of chemical curing type of glass ionomer cements. 4. Light curing type glass ionomer cement was etched by acid, but there was no difference in surface appearances according to various waiting periods. 5. It was found that the value of plane stram fracture toughness of glass ionomer cements was highest in the light curing filling type as $1.79\;MNm^{-1.5}$ followed by the light curing lining type, chemical curing metal reinforced type, chemical curing filling type and chemical curing lining type. 6. The value of plane stram fracture toughness of the chemical curing lining type glass ionomer cement etched after 5 minutes was lower than those of the cement etched after 1 hour or day or unetched (P < 0.05). 7. Light curing glass ionomer cement showed Irregular fractured surface and chemical curing cement showed smooth fractured surface.

  • PDF

PHYSICAL PROPERTIES OF DIFFERENT SELF-ADHESIVE RESIN CEMENTS AND THEIR SHEAR BOND STRENGTH ON LITHIUM DISILICATE CERAMIC AND DENTIN (수종의 자가 접착 레진 시멘트의 물성 및 lithium disilicate ceramic과 상아질에 대한 전단결합강도 비교)

  • Shin, Hye-Jin;Song, Chang-Kyu;Partk, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.184-191
    • /
    • 2009
  • The purpose of this study was to evaluate the physical properties of different self-adhesive resin cements and their shear bond strength on dentin and lithium disilicate ceramic and compare these result with that of conventional resin cement. For this study, four self-adhesive resin cements (Rely-X Unicem, Embrace Wetbond, Mexcem, BisCem), one conventional resin cement (Rely-X ARC) and one restorative resin composite (Z-350) were used. In order to evaluate the physical properties, compressive strength, diametral tensile strength and flexural strength were measured. To evaluate the shear bond strength on dentin, each cement was adhered to buccal dentinal surface of extracted human lower molars. Dentin bonding agent was applied after acid etching for groups of Rely-X ARC and Z-350. In order to evaluate the shear bond strength on ceramic, lithium disilicate glass ceramic (IPS Empress 2) disks were prepared. Only Rely-X ARC and Z-350 groups were pretreated with hydrofluoric acid and silane. And then each resin cement was adhered to ceramic surface in 2 mm diameter. Physical properties and shear bond strengths were measured using a universal testing machine. Results were as follows 1. BisCem showed the lowest compressive strength, diametral tensile strength and flexural strength. (P<0.05) 2. Self-adhesive resin cements showed significantly lower shear bond strength on the dentin and lithium disilicate ceramic than Rely-X ARC and Z-350 (P<0.05) In conclusion, self-adhesive resin cements represent the lower physical properties and shear bond strength than a conventional resin cement.