• 제목/요약/키워드: cell control

검색결과 10,015건 처리시간 0.044초

PV-SPE 시스템을 위한 새로운 MPPT 제어의 운전특성 분석에 관한 연구 (Analysis on Operational Characteristics of PV-SPE System by a Novel MPPT Control)

  • 최종호;이동한;김종현;김재호;박민원;유인근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.121-124
    • /
    • 2006
  • In the newly developed control method, the current flowing into SPE cell is the only one considerable factor. So, the structure of control circuit becomes simple and the manufacturing cost of the control device decreases. In conventional power comparison MPPT control method however, a voltage and current coming out from PV cell should be feedbacked to chase maximum power point at every moment. Then, the structure of control circuit becomes so complex and the risk of control failure is much higher than the novel MPPT control method. Therefore, PV generation system by a novel MPPT control method is especially operated much more safely in case of a huge system, because the voltage coming out from PV-cell is not needed to be feedbacked. In this paper, the PV-SPR system was actually manufactured based on the simulation model of PSCAD/EMTDC program and the results tested were shown. Authors are sure that it is the most useful method to maximize power from PV to SPE with only a feedback of SPE input current.

  • PDF

퍼지 제어를 이용한 수소 상용차 전력 분배 시뮬레이션 (Commercial Hydrogen Vehicle Power Distribution Simulation Using Fuzzy Control)

  • 한재수;한재수;우종빈;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제34권4호
    • /
    • pp.369-380
    • /
    • 2023
  • There is no clear standard for estimating the power distribution of fuel cells and batteries to meet the required power in hydrogen electric vehicles. In this study, a hydrogen electric vehicle simulation model equipped with a vehicle electric component model including a fuel cell system was built, and a power distribution strategy between fuel cells and batteries was established. The power distribution model was operated through two control strategies using step control and fuzzy control, and each control strategy was evaluated through data derived from the simulation. As a result of evaluation through the behavior data of state of charge, fuel cell current and balance of plant, fuzzy control was evaluated as a proper strategy in terms of control stability and durability.

Clinical Study on Mannan Peptide Combined with TP Regimen in Treating Patients with Non-small Cell Lung Cancer

  • Yan, Huai-An;Shen, Kang;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권8호
    • /
    • pp.4801-4804
    • /
    • 2013
  • Purpose: To investigate short-term response rate, quality of life and toxicities of mannan peptide combined with TP regimen in treating patients with non-small cell lung cancer (NSCLC). Patients and Methods: Forty one patients with NSCLC were divided into an experimental group treated with TP regimen combined with mannan peptide (21 patients) and a control group treated with TP alone (20 patients). Results: Response rates were 61.9% (13/21) for the experimental and 60% (12/20) for the control group (p>0.05). Regarding toxicity, white blood cell decreased more frequently in the control group (65%, 13/20) than in the experimental group (33.3%, 7/21) (p<0.05); nausea and vomiting also occurred more frequently in the control group (55%, 11/20 vs 23.8%, 5/21) (p<0.05). In terms of quality of life, this index was improved by 57.1% (12/21) and 25% (5/20) in experimental and control groups, respectively (p<0.05). Conclusions: Response rate of TP after combined with mannan peptide is mildly increased, while this combination alleviates bone marrow suppression as well as nausea and vomiting of TP, and improves quality of life when treating patients with NSCLC. However, this conclusion should be confirmed by randomized clinical trails.

모델 예측 제어 기반 Cascaded H-bridge 컨버터의 균일한 손실, 스위칭 주파수, 전력 분배를 위한 알고리즘 (An Algorithm for Even Distribution of Loss, Switching Frequency, Power of Model Predictive Control Based Cascaded H-bridge Multilevel Converter)

  • 김이김;곽상신
    • 전력전자학회논문지
    • /
    • 제20권5호
    • /
    • pp.448-455
    • /
    • 2015
  • A model predictive control (MPC) method without individual PWM has been recently researched to simplify and improve the control flexibility of a multilevel inverter. However, the input power of each H-bridge cell and the switching frequency of switching devices are unbalanced because of the use of a restricted switching state in the MPC method. This paper proposes a control method for balancing the switching patterns and cell power supplied from each isolated dc source of a cascaded H-bridge inverter. The supplied dc power from isolated dc sources of each H-bridge cells is balanced with the proposed cell balancing method. In addition, the switching frequency of each switching device of the CHB inverter becomes equal. A simulation and experimental results are presented with nine-level and five-level three-phase CHB inverter to validate the proposed balancing method.

Adaptive Control of Peak Current Mode Controlled Boost Converter Supplied by Fuel Cell

  • Bjazic, Toni;Ban, Zeljko;Peric, Nedjeljko
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.122-138
    • /
    • 2013
  • Adaptive control of a peak current mode controlled (PCM) boost converter supplied by a PEM fuel cell is described in this paper. The adaptive controller with reference model and signal adaptation is developed in order to compensate the deviation of the response during the change of the operating point. The procedure for determining the adaptive algorithm's weighting coefficients, based on a combination of the pole-zero placement method and an optimization method is proposed. After applying the proposed procedure, the optimal adaptive algorithm's weighting coefficients can be determined in just a few iterations, without the use of a computer, thus greatly facilitating the application of the algorithm in real systems. Simulation and experimental results show that the dynamic behavior of a highly nonlinear control system with a fuel cell and a PCM boost converter, can fairly accurately be described by the dynamic behavior of the reference model, i.e., a linear system with constant parameters.

The effect of the site of laser zona opening on the complete hatching of mouse blastocysts and their cell numbers

  • Sanmee, Usanee;Piromlertamorn, Waraporn;Vutyavanich, Teraporn
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제43권3호
    • /
    • pp.152-156
    • /
    • 2016
  • Objective: We studied the effect of the site of laser zona opening on the complete hatching of mouse blastocysts and the cell numbers of the completely hatched blastocysts. Methods: Mouse blastocysts were randomly allocated to the inner cell mass (ICM) group (zona opening performed at the site of the ICM, n=125), the trophectoderm (TE) group (zona opening performed opposite to the ICM, n=125) and the control group (no zona opening, n=125). Results: The rate of complete hatching of the blastocysts was not significantly different in the ICM and the TE group (84.8% vs 80.8%, respectively; p=0.402), but was significantly lower in the control group (51.2%, p<0.001). The cell numbers in the completely hatched blastocysts were comparable in the control group, the ICM group, and the TE group ($69{\pm}19.3$, $74{\pm}15.7$, and $71{\pm}16.8$, respectively; p=0.680). Conclusion: These findings indicate that the site of laser zona opening did not influence the rate of complete hatching of mouse blastocysts or their cell numbers.

Overexpression of Protein Kinase $C{\beta}_1$ Restores Mitogenic Responses of Enterocytic Differentiated Colon Carcinoma Cells to Diacylglycerol and Basic FGF

  • Lee, Han-Soo
    • BMB Reports
    • /
    • 제30권3호
    • /
    • pp.194-199
    • /
    • 1997
  • Previous studies have shown that the HD3 human enterocytic differentiated colon carcinoma cell lines having low $PKC{\beta}$ activity did not respond to diacylglycerol and basic FGF by growth and by activation of pp57 MAP kinase, but undifferentiated cell lines exhibiting high $PKC{\beta}$ activity did. To confirm a role of $PKC{\beta}$ in colonocyte mitogenesis, derivatives of HD3 cell line that stably overexpress a full-length of cDNA encoding the ${\beta}_1$ isoform of human PKC were generated. The abundance and activity of $PKC{\beta}$ in two of the these cell lines, PKC3 and PKC8 were much higher than those in the C1 control cell line that carries the vector lacking the $PKC{\beta}_1\;cDNA$ insert. Following exposure to diacylglycerol or basic FGF, proliferation of PKC3 and PKC8 cells increased about 50%; but this effect was not seen with the control C1 cells. Also, in contrast to the control cells, the $PKC{\beta}_1-overproducing$ cells displayed activation of pp57 MAP kinase when treated with diacylglycerol and basic FGF as undifferentiated cell lines did. These results provide direct evidence that $PKC{\beta}_1$ which plays a key role in mitogenic responses of colon carcinoma cells to diacylglycerol and basic FGF is down-regulated in enterocytic differentiation of colon cells.

  • PDF

The Study of Mutation Spectrum in Iac / Gene of Transgenic Big Blue$\textregistered$ Cell Line Following Short-Term Exposure to 4-Nitroquinoline N-oxide

  • Youn, Ji-Youn;Kim, Kyung-Ran;Cho, Kyung-Hea;Ryu, Jae-Chun
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 1996년도 제19회정기학술대회(The 19th Symposium of the Korean Society of Environmental Toxicology)
    • /
    • pp.64-64
    • /
    • 1996
  • Transgenic animal and cell line models which are recently developed in toxicology field combined with molecular biological technique, are powerful tools for studying of mutation in vivo and in vitro, respectively. The Big Blue mutagenesis assay system is one of the most widely used transgenic systems. Especially, for the study of direct acting mutagens, Big Blue cell line is very useful and powerful to evaluate mutagenicity because the mutation frequency and mutationspectrlun showed no distinct differences between cell line and animal. The Big Blue cell lines carry stably integrated copies of lambda shuttle vector containing lac I gene as a mutational target. These lambda shuttle vectors are useful for various mutagenesis related studies in eukaryotic system due to their ability to be exposed mutagen and then transfer a suitable target DNA sequence to it convenient organism for analysis. We tried to assess the mutagenic effect of 4-NQO with Big Blue cell line. After the treatment of 4-NQO, genomic DNA was isolated and lambda shuttle vector was packaged by in Vitro packaging and then these were plated on bacterial host in the presence of X-gal to screen mutation in the lac I. We determined MF as a ratio of blue plaques versus colorless plaques and now undergoing the mutation spectrum of 4-NQO in lac J gene sequence.

  • PDF

와류 셀을 이용한 풍력블레이드 에어포일 주위 유동 제어 (Flow Control on Wind Turbine Airfoil with a Vortex Cell)

  • 강승희;김혜웅;유기완;이준신
    • 한국항공우주학회지
    • /
    • 제40권5호
    • /
    • pp.405-412
    • /
    • 2012
  • 높은 효율의 풍력터빈 블레이드을 위해 와류 셀이 장착된 에어포일의 정지상태 및 동실 속 상태에서의 유동제어 특성을 수치적으로 연구하였다. 수치기법은 Roe의 flux-difference-splitting을 사용한 격자점 중심 유한체적법과 이중시간 전진 기법을 사용하는 내재적 시간적분법을 사용하였다. 계산결과 와류 셀을 장착한 경우 셀 내부의 부압으로 인해 양항비증가를 얻을 수 있음을 확인하였다. 동실속의 경우 셀 내부의 와류에 의해 hysterisis 현상을 상당히 감소시킬 수 있음을 확인하였다.

An Arithmetic System over Finite Fields

  • Park, Chun-Myoung
    • Journal of information and communication convergence engineering
    • /
    • 제9권4호
    • /
    • pp.435-440
    • /
    • 2011
  • This paper propose the method of constructing the highly efficiency adder and multiplier systems over finite fields. The addition arithmetic operation over finite field is simple comparatively because that addition arithmetic operation is analyzed by each digit modP summation independently. But in case of multiplication arithmetic operation, we generate maximum k=2m-2 degree of ${\alpha}^k$ terms, therefore we decrease k into m-1 degree using irreducible primitive polynomial. We propose two method of control signal generation for the purpose of performing above decrease process. One method is the combinational logic expression and the other method is universal signal generation. The proposed method of constructing the highly adder/multiplier systems is as following. First of all, we obtain algorithms for addition and multiplication arithmetic operation based on the mathematical properties over finite fields, next we construct basic cell of A-cell and M-cell using T-gate and modP cyclic gate. Finally we construct adder module and multiplier module over finite fields after synthesizing ${\alpha}^k$ generation module and control signal CSt generation module with A-cell and M-cell. Next, we constructing the arithmetic operation unit over finite fields. Then, we propose the future research and prospects.