• Title/Summary/Keyword: ceiling materials

Search Result 150, Processing Time 0.026 seconds

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

Current Interior Design and User Preference for Child Care Facilities - Focused on Interior Atmosphere, Finishing Materials and Colors - (보육시설 실내디자인 현황과 사용자 선호성향 - 실내분위기, 마감재, 색채를 중심으로 -)

  • Ha, Sook-Nyung;Chun, Jin-Hie
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.111-122
    • /
    • 2008
  • As Korea has undergone rapid modernization, urbanization and industrialization, women's social participation has increased. Accordingly, child care facilities have shown continuous growth in numbers. However, according to research, child care facilities in Korea lag behind those in other nations in terms of quality. Given that, it seem urgent to enhance the quality of child care facilities and improve their indoor environment. Above all, overall atmosphere, colors and finishing materials are connected directly with educational effects as well as feelings and health of facility users. This study assesses the current state of child care facilities and preferences by focusing primarily on interior atmosphere, materials and colors. For This Study, 7 facilities were surveyed, and 46 subjects were participated for this study. The findings suggest that "pretty" style is preferred to "natural" style. As regards flooring material, wood floor is preferred. It is recommended to lay pastel colored carpet or PVC flooring material to the wood floor. As for wall, it is desirable to divide the wall spaces by adding wood and painting to simple wallpapers. In case of the ceiling noise absorptive material is recommended to use instead of wallpapers. For the doors, it is desirable to use contrasting materials and colors given accessibility for children. In the meantime, rather than strong primary colors, soft color or pastel colors are desirable for furniture. This study has limitations because of insufficiency of case study samples. However, it is significant in that the study results may be used as primary source of information to improve the environment of child care facilities.

Study on the Manufacturing Technology of Mural Tomb in Goa-dong of Daegaya Period (대가야 고아동 고분벽화 제작기술에 관한 연구)

  • Lee, Hwa Soo;Lee, Han Hyeong;Lee, Kyeong Min;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.457-466
    • /
    • 2014
  • Rigorous analysis was performed to identify the structure and materials of the murals to study techniques used on mural tombs of ancient Daegaya era(6th century). The murals were painted by applying mortar on the walls and the ceiling after building a stone chamber and creating ground layers on mortar layers. Mud was applied on most of the mortar layers on four sides of the walls except the ceiling. Sand was not used in mortar but was made of materials with pure calcium substances. In addition, shells in irregular sizes with incomplete calcination were mixed; and the mortar's white powder was inferred as lime obtained by calcination of oyster shells. Kaolinite($Al_2Si_2O_5(OH)_4$) was used in the ground layer, Cinnabar(HgS) was used for red pigment, Malachite($Cu_2CO_3(OH)_2$) for green and Lead white($PbCO_3{\cdot}Pb(OH)_2$) for white. Mud plaster was applied on the mortar and was composed thinly and densely using clayey of particle size smaller than that of medium sand. It was assumed that the finishing was for repair after long time had passed since the mortar layer came off. Using lime made with oyster shells as mortar is unprecedented in ancient Korean mural tombs and its durability was very poor, suggesting that Gaya's mortar production technique was relatively behind compared to that of Koguryo's in the same era.

Estimation of the Asbestos Handling History of Workers in the Automobile Manufacturing Industry in Korea (자동차 제조 사업장 근로자들의 석면 취급 이력 추정)

  • Choi, Sangjun;Kim, Shinbum;Choi, Youngeun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.423-432
    • /
    • 2017
  • Objectives: This study was conducted to evaluate asbestos handling history of workers at automobile manufacturing plants in Korea. Methods: National regulations on asbestos and Korea Occupational Safety and Health Agency(KOSHA) database on the information of asbestos containing products were reviewed. We investigated asbestos related materials from one automobile manufacturing plant. Material safety data sheets(MSDS) collected in 2010, work environment monitoring results reported from 2000 to 2013, trade union reports and asbestos survey reports were reviewed. We also interviewed workers with long career and did walk-through survey. Results: The Ministry of Labor in Korea has permitted asbestos manufacturing since 1990. In 1997, the use of crocidolite and amosite asbestos were banned. In 2007, the Korean government announced a total ban on the manufacturing, importation and use of all kinds of asbestos, which took full effect in 2009. A total of 174 asbestos products information from KOSHA database was analyzed. Extruded cement panel for building, special brake for crane farm machinery, gasket, joint sheet and thermal insulator were produced until 2007. From automobile manufacturing plant survey, we confirmed that asbestos containing materials(ACM) such as gasket, heating induction materials have been used until 2011. Asbestos containing building materials(ACBM) such as bamlites, slate and ceiling tex were reported at 122 asbestos dismantling projects in 2014. Conclusion: Although the use of all kinds of asbestos were banned from 2009, ACMs and ACBMs installed before 2009 were still found at automobile manufacturing plant until 2011 and 2014 respectively. In particular, asbestos slates should be managed because most of slates had not been removed until 2014.

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

An Asbestos Risk Assessment and Areal Distribution of Asbestos Containing Materials in Public Buildings (석면함유 공공 건축물의 위해성 평가 및 면적 분포 특성)

  • Song, Su-Jin;Jang, Bong-Ki;Jo, Bong-Hyun;Kim, Yeong-Ji;Heo, Eun-Hyeop;Lee, Joung-Dae;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.267-276
    • /
    • 2016
  • Objectives: This study, aims to examine the distribution characteristics of asbestos-containing building materials; risk assessment and area of distribution of asbestos-containing building materials depending on year of construction; building materials; types of building materials; and usage in public buildings in order to create fundamental data for safe management of public buildings. Methods: The asbestos investigation was conducted by an asbestos research institution from March to May 2014, targeting 41 public buildings which were subject to asbestos investigation in South Chungcheong-do Province. With respect to 381 presumed asbestos-containing materials, an investigation was conducted into whether they contained asbestos, asbestos type, content, year of construction, and use in the building were examined, and a risk assessment was performed. Results: Asbestos-containing building materials were used in 35 buildings(85.4%). Among them, 31(88.6%) were public buildings. Asbestos was detected in 73% of 381 suspected asbestos-containing materials, which were mostly ceiling materials (85.2%). The older the buildings, the more they showed a tendency to have a significantly higher risk assessment score. The ratio of average area with asbestos-containing building materials to total floor area was 57.6%, 44.1%, and 17.8% for buildings built in the 1980s, 1990s, and 2000s, respectively. This showed a tendency to be significantly higher with the age of the building. Conclusions: From the results above, it can be concluded that with the age of the buildings, the risk assessment score and the ratio of average area with asbestos-containing building materials to total floor area became significantly higher. Given the concern about the exposure to asbestos of residents and civil petitioners, safety management of older public buildings and measures for dismantling and removal of asbestos-containing building materials should therefore be urgently established.

A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System (가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • In this study fire control characteristics for inflammable materials of water curtain system are experimentally analyzed. Heat release rate for pinewood and gasoline was calculated using Room Corner Tester (RCT) and fire test apparatus for water curtain system is manufactured. Nozzles (180 degree of injection angle, 8.2 mm of orifice diameter) are installed at the nearby ceiling of place at 5 m distance from fire originate and temperature profile as well as transmission are obtained from the fire experiment of pinewood and gasoline in the water curtain system. Based on the results, parameters of engineering importance for fire control characteristics of water curtain system such as generation of high temperature smoke and thermal phenomena of fluid flow by injection nozzle are identified.

Asbestos Determination of Some Domestic Building-Materials Using X-ray diffraction (국내 건축자재에 함유된 석면의 함량에 대한 X-선회절분석 연구)

  • Hwang, Jin-Yeon;Lee, Hyo-Min;Oh, Ji-Ho;Park, Gi-Nam
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.119-131
    • /
    • 2011
  • The asbestos contents in some representative building materials were analyzed using JIS (Japanese Industrial Standard) X-ray diffraction (XRD) method. The changes in mineral composition during analysis process and problems in JIS method were also examined. XRD analysis of some representative domestic building materials used for roof, wall, ceiling, and floor indicates that slate have the highest asbestos content having 6.87~6.93% of chrysotile. Other building materials analyzed in this study also have 1.35~3.98% of chrysotile contents. The XRD analysis results of asbestos contents in some domestic building materials are presented in this study. This method is very effective for the asbestos content evaluation of building materials according to newly modified asbestos content regulation (Law of Industrial Safety and Health, 2007-26) that limits asbestos content less than 0.1% by Ministry of Employment and Labor. Small amount of tremolite as well as chrysotile were also observed in some samples. With consideration of crystal shape, contents and geological occurrence, it is considered that tremolite is an associated mineral of chrysotile and is not intentionally added. Complemental analyses with optical microscope and SEM/EDS are also necessary because XRD method cannot distinguish asbestiform from non-asbestiform. The XRD method applied in this study is very effective in the asbestos content analysis of building materials, specially building materials showing high asbestos concentration in residues due to the high loss rate with ashing and acid dissolution procedure.

Investigation of the Speech Intelligibility of Classrooms Depending on the Sound Source Location

  • Kim Jeong Tai;Haan Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.4E
    • /
    • pp.139-143
    • /
    • 2005
  • The present study aims to investigate the effects of speaker location on the speech intelligibility in a classroom. In order to this, acoustic measurements were undertaken in a classroom with three different sound source locations such as center of front wall (FC), both sides of front wall (FS) and the center of ceiling (CC). SPL, RT, $D_{50}$, RASTI were measured in the 9 measurement points with same sound power level of sound source and MLS was used as the sound source signal. Also, subjective listening tests were carried out using Korean language listening materials which were recorded in an anechoic chamber. The recorded syllables were replayed and recorded again in the classroom with same sound source at three different locations and listening tests were undertaken to 20 respondents who were asked to write the correct syllables which were recorded in the classroom. The results show that higher sound intelligibility ($D_{50}$ of $47\%$, RASTI of 0.56) was obtained when sound source was located at the FS. The results also show that high sound intelligibility was obtained at the area nearby walls.

Analysis of Novel Helmholtz-inductively Coupled Plasma Source and Its Application for Nano-Scale MOSFETs

  • Park, Kun-Joo;Kim, Kee-Hyun;Lee, Weon-Mook;Chae, Hee-Yeop;Han, In-Shik;Lee, Hi-Deok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.35-39
    • /
    • 2009
  • A novel Helmholtz coil inductively coupled plasma(H-ICP) etcher is proposed and characterized for deep nano-scale CMOS technology. Various hardware tests are performed while varying key parameters such as distance between the top and bottom coils, the distance between the chamber ceiling and the wafer, and the chamber height in order to determine the optimal design of the chamber and optimal process conditions. The uniformity was significantly improved by applying the optimum conditions. The plasma density obtained with the H-ICP source was about $5{\times}10^{11}/cm^3$, and the electron temperature was about 2-3 eV. The etching selectivity for the poly-silicon gate versus the ultra-thin gate oxide was 482:1 at 10 sccm of $HeO_2$. The proposed H-ICP was successfully applied to form multiple 60-nm poly-silicon gate layers.