• 제목/요약/키워드: ceiling materials

검색결과 150건 처리시간 0.026초

간역잠실(簡易蠶室)의 난방부하특성(暖房負荷特性) 및 보온(保溫)커튼 설치(設置)효과에 관한 연구(硏究)(II) -보온(保溫)커튼의 열(熱) 절감(節減) 효과(効果) 및 적응성(適應性) 검토(檢討)- (Study on Heating Load Characteristics and Thermal Curtain Effects for Simple Silkworm Rearing Houses(II) -Effects of the Thermal Curtain on Energy Preservation and Review of its Application-)

  • 최광재;정두호;박경규
    • Journal of Biosystems Engineering
    • /
    • 제16권1호
    • /
    • pp.83-89
    • /
    • 1991
  • One of the most serious problems in Korean sericulture farms is to improve the adiabatic conditions for the simple silkworm rearing houses which has been widely adapted since early 1980'. Thus, this study is aimed to solve the problems by selecting the thermal screen material and by finding the method of its instalation. For the study, 4 kinds of materials which are (1) TE005,(2) NW60, (3) NW300 and (4) AL110 are selected and 4 different types of methods which are surrounding boundary of rearing bed(type A), surrounding inside of wall and ceiling (type B), installing on inside of wal ony (type C) and installing on ceiling Inly (type D) are installed. Decision criteria of the best combination of screen material and installation methods is made by calculating the heating load coefficients and by testing the application at the simple silkworm rearing houses. The obtained results are summarized as follows ; 1. The effect of thermal screen on reducing the thermal energy is remarkable. It saves energy more 50% than unscreened simple silkworm rearing houses. 2. From a stand point of a good screed material on thermal energy reduction, the NW300, AL110 and PE005 are recommanded materials. However, NW60 and PE005 are regarded as desirable materials from the practical point view. 3. Also, the effect on thermal energy reduction is largely affected by the method of thermal screen installation. The surrounding boundary of the silkworm rearing bed(type A) is the most desirable method to reduce the energy, which saves 56.6% of it. 4. In the practical application, NW60 and type A is considered to be the best combination of material and installation method. By this combination, the level of maximum heating load can be reduced at the rate of 43% for spring season and 40% for autumn season. 5. Another heating method, comparted heating, can be recommended to save the energy.

  • PDF

Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

  • Lokade, Joyti;Rawlani, Shivlal;Baheti, Rakhi (Chandak);Roy, Shelly;Chandak, Manoj;Lohe, Vidya
    • Journal of Korean Dental Science
    • /
    • 제4권1호
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

초등학교 일반교실의 색채 환경 평가에 관한 비교연구 - 제7차 교육과정 전.후의 광주광역시내 초등학교를 중심으로 - (Comparative Study on Color of Environment Evaluation of General Classrooms at Elementary Schools - With elementary schools in Gwang-ju Metropolitan City Since the 7th Curriculum -)

  • 노영진;박성진;이청웅
    • 한국실내디자인학회논문집
    • /
    • 제16권5호
    • /
    • pp.89-97
    • /
    • 2007
  • This study compares, analyzes and reevaluates color conditions and images before and after the execution of the 7th curriculum with elementary schools in Gwang-ju Metropolitan City based on the fact that color among physical environments of elementary classrooms has an important influence on children's emotion and draws problems and aims to accumulate the basic materials for preparing guidelines of improving color environment at general classrooms of elementary schools. Consequently, according to color conditions, major colors on ceiling and wall were high brightness/nigh chroma of Y and YR line regardless of division of grades and other color factors of classroom showed that wall and ceiling used similar colors, but brightness was higher after change than before it. In evaluation of color images, lower grades showed negative color images such as 'common,' 'rustic,' and 'strange' before change, but they showed positive color images after change such as 'clean,' 'unique,' and 'soft'. But, most of higher grades showed negative reactions before change such as 'common,' 'strange,' and 'rustic' and they showed positive reactions after change only in such items as 'clean,' 'warm,' and 'unique', but Indicated negative reactions in remaining items such as 'strange,' 'rustic,' 'stiff,' and 'artificial'. Accordingly, in using colors for lower grade classroom, arrangement of colors through adjustment of brightness and chroma between ceiling, wall and other components based on coloring of high brightness and low chroma of similar colors should be considered and for higher grade classroom, arrangement of colors of unique images of mid-brightness/mid-chroma among warm color lines of similar colors should be examined.

샌드위치패널 창고의 벽 천장 접합부 방호용 스프링클러설비 실험 (A Experiment of Sprinkler System to Protect Ceiling Joints of Sandwich Panel Warehouses)

  • 안병국;김운형;서동훈;함은구
    • 한국재난정보학회 논문집
    • /
    • 제15권1호
    • /
    • pp.98-108
    • /
    • 2019
  • 연구목적:본 연구는 화재 시 샌드위치패널 구조 창고의 벽 천장접합부 방호를 위한 스프링클러 성능확인 실험을 목적으로 한다. 연구방법: 현장조사결과를 기반으로 창고의 공간규격과 가연물을 선정하고 벽 코너 및 헤드 직하부에서의 방호실험을 수행하고 결과를 분석하였다. 연구결과:벽 코너 화재 시나리오에 대해서 K-80 폐쇄형 스프링클러헤드의 작동으로 샌드위치 패널의 착화 및 접합부 손상이 방지됨을 확인하였다. 결론:샌드위치패널 심재로의 착화 및 연소방지를 통한 화세제어로 이를 가정한 소방대의 소화 및 구조활동을 위한 표준진압대책이 마련되어야 한다.

천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능 (Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket)

  • 이승재;곽의신;박재성;강창훈;손수덕
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

화재하중을 통한 사찰의 화재 위험성 평가에 관한 연구 (A Study on Fire Risk Assessment of the Temple Using Fire Loads)

  • 김수영;신영주;박영주;이해평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.409-415
    • /
    • 2008
  • In this study, we considered the fire risk assessment of the temple using fire loads and the classification of combustibles. The building construction materials were classified as walls, beam-columns, floorings, ceiling panels and the loading combustibles were classified into fixed materials and movable materials. As a result, we confirmed that the total fire load of the Palsangjeon was $368\;kg/m^2$. The building construction materials accounted for approximately 93.8 percent of the total fire load and the loading combustibles accounted for approximately 6.2 percent.

  • PDF

현대 실내디자인에 있어 재료와 공간의 상호관계성에 관한 연구 (A Study on the Interrelation of Material and Space in Modern Interior Design)

  • 이상협;김문덕
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.187-191
    • /
    • 2003
  • Modern interior design is expanding diversely, with the rapid development of technology and change of era. The basic of interior space that is rapidly changing consists of floor, wall and ceiling, and these are formed by materials, materials for structure or finishing materials. In the modern interior space, materials are utilized to present an atmosphere that meets the trend of the dissolution of post-modernism and the trend of minimalism. Accordingly, in this study, designers who take serious view on the relation of space and material, and the relation focusing on completed works, in modern interior design were investigated. The interrelation of the representation of each material, organic space, minimal space, and the space of Oriental fusion style were investigated through the works of modern interior designers, such as Karim Rashid and Ettore Sottsass.

  • PDF

건축물의 실내건축 재료에 관한 화재안전성 연구 (A Study on the Fire Safety Performance of Interior Surface Materials in a Building)

  • 서수은;신승우
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 추계학술대회
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

커버 가동에 의한 실내용 천정조명기구 눈부심 제어 (Glare control of a ceiling luminaire with movable cover)

  • 김후성;여인선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2007
  • This study attempts to prove a superiority of slide-cover lighting. In order to solve these problems, cover materials with slide-type, blind cover should be prepared to make it easy to replace the light bulbs in a short time and to introduce a sense of decorative taste. Depending on an user's linking, slide-type cover can always change the indoor atmosphere by adjusting the light emitted from the lighting and meeting with the blind unit

  • PDF

실측을 통한 대학부설 유치원의 실태분석 (A survey of actual conditions on the Kindergarten attached to colleges through actual measurement)

  • 석주영
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 1994년도 학술발표대회논문집 하
    • /
    • pp.51-55
    • /
    • 1994
  • This study was attempted to investigate the facilities and environments of kindergarten attached to colleges, and ultimately to make up the adequate environment of for children. For these purposes, investigators directly visited 6 kimdergartens attached to colleges, and actually measured the facilities and equipments of these kindergartens. Concretely, our invetigators analyzed the actual conditions of kindergarten attached to colleges contering around the lighting and illumination of classroom, corridor, hall, toile room, dining room, and furnitures, closing materials of the floor, wall, ceiling.

  • PDF