• Title/Summary/Keyword: ceiling materials

Search Result 150, Processing Time 0.026 seconds

Fire test procedures for flammability of bulkhead, ceiling and deck finish materials (선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법)

  • Kim, S.Y.;Kim, D.S.;Ahn, B.H.;Kwark, J.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.117-119
    • /
    • 2008
  • It is very important to protect life, property at sea from any fire. Recommendation on improved fire test procedures for surface flammability of bulkhead, ceiling and deck finish materials specifies a procedure for measuring fire characterizing their flammability and thus their suitability for use in marine construction. In this paper, we investigated the positive expected by fire test procedures for flammability of bulkhead, ceiling and deck finish materials. Also, unusual materials were analyzed. Finally, we suggest methods to solve several problems related to unusual materials.

  • PDF

The Comparison of the Characteristics Regarding Interior Spaces for TV News Centers (TV 뉴스센터 스튜디오의 실내 공간에 관한 특성 비교)

  • Kim, Dongsik;Sung, Lee-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.197-206
    • /
    • 2015
  • The purpose of this study is to analyze characteristic interior spaces for TV news center studio. Based on eight channels including public and comprehensive programming broadcasting stations the method for this research is to make differentiate existing relevant literature by creating analysis items for interior spaces through various case studies as well as find out characteristics of spatial forms, colors, materials, decorations, and etc. The conclusions are as follows. Firstly, spatial form of desk and ceiling are similar shapes but floor and wall are different comparing with public and comprehensive programming broadcasting stations. Secondly, preferred color for floor and ceiling is black, for wall and desk are blue and gray. Thirdly, various materials are preferred between public and comprehensive programming broadcasting stations. Fourthly, Flat and elevated floors are preferred as well as space and logos of broadcasting station are preferred for background images as decoration elements. Lastly, Soffit ceiling, desk accommodating more than 4 people, spotlight for public broadcasting stations, and architectural lighting for comprehensive programming broadcasting stations are preferred.

SMOKE SPREAD IN A CORRIDOR

  • Kim, Myung-Bae;Han, Yong-Shik;Park, Jun-Seok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.464-471
    • /
    • 1997
  • Convective smoke spread in a corridor is experimentally investigated using thermocouples and visualization technique with a laser beam sheet. The speed of smoke front under a ceiling is measured by a series of thermocouples. Visualization of the ceiling jet formation and of smoke filling process is carried out to observe the lowering of a smoke layer. From the results, a large-scale convective motion plays dominant roles for smoke spread in the vicinity of the end of the corridor from visualized photos along with temperature records. The large-scale convective motion of the smoke is generated from the impingement of the ceiling jet front on the end of the corridor, and thus turning the flows toward the floor. Such a circulating motion of fluid transports some smoke to some region where its momentum is effective. It is therefore shown that the conventional concept of lowering smoke in the two-layer zone model has some restrictions for the corridor because the lowering of smoke layer has been thought to be mass transport due to relatively small scale motions such as the decrease of buoyancy, mass diffusion and momentum exchanges.

  • PDF

Floor Impact Sound Isolation Performance by Composition of Ceiling and Wall (천장 및 벽구성 방법이 바닥충격음 차단성능에 미치는 영향에 관한 연구)

  • Kim Kyoung-Woo;Kang Jea-Sik;Lee Seung-Eon;Yang Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.465-473
    • /
    • 2005
  • The impact sounds, generated by the walking of people, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The characteristics and level of this impact noise depends on the object striking the floor, on the basic structure of the floor, and on the finish materials of floor. The focus of this paper is to investigate the amount of improvement impact sound pressure level according to the change of the composition method of ceiling and wall. For this purpose, we tested impact sound pressure level of several cases which is the inserting of mineral wool, the increase of the thickness of air layer, the using of anti-vibration rubber in ceiling and attach the mineral wool on wall in the Floor Impact Sound Test Building of KICT. The results show that the composition method of ceiling and wall is more effective in the reduction of light weight impact sound specially in 125Hz and 250Hz.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

A Study of the Interior Restorations in the Pre-Modern Architecture - Focused on Concepts of the Preservation, Restorations of the Wall and Ceiling - (근대건축물 문화재의 실내장식 수복에 관한 연구( I ) - 보존의 개요와 벽체 및 천장수복을 중심으로 -)

  • 김란기;윤영선
    • Korean Institute of Interior Design Journal
    • /
    • no.41
    • /
    • pp.36-44
    • /
    • 2003
  • This study is arranged the principles of the preservation and restoration in pre-modern architecture, presented guideline of the interior restoration in there, and attempted relative-analysis by cases of Japan in wall and ceiling. The method of Original-restorations and Repairs must be preserved in materials and technologies in order to hand over the future generations. The process and method of restorations are the important Cultural Properties as Architecture's itself.

A Study on Experimental Characteristics in Fire Investigation Techniques of Flammable Liquids (유류화재의 감식기법의 실험적 특성에 관한 연구)

  • Hwang, Taeyeon;Choi, Donmook
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.7-14
    • /
    • 2012
  • This paper is to develop analytical techniques of flammable liquids which have been used for accelerating fire in accidental fires and arsons. We tested the temperature distribution of ceiling, fire patterns on the floor, and existence of flammable liquids and a check with GC/MS about flammable liquids comparing with papers, newspapers, and clothing. Research findings are as follows. The temperature of ceiling is influenced by flame. So gasoline and thinner was observed that combustible materials would be burned by flame. The fire patten on the floor was observed that flammable liquids had specialized pattern comparing combustible materials. When combustible materials on the PVC (Polyvinyl chloride) floor was burned, they didn't react to the gas detector. But flammable liquids had opposite results. After 7 days, we identified components of fire residues with the GC/MS (Gas Chromatography/Mass Spectrometry) about existence of flammable liquids and got components of flammable liquids. Fire investigation is a complicated processes. But we understand characteristics of materials, need detail investigations, and use the GC/MS to analyse flammable materials.

Comparison of Sound Transmission Loss of Panels Used in Ship Cabins for Field and Laboratory Measurements

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1E
    • /
    • pp.9-15
    • /
    • 2009
  • In this paper, FSTL (Field Sound Transmission Loss) measured in a mock-up simulating ship cabins is studied. A mock-up is built by using 6 mm steel plate, and two identical cabins are made where 25 mm or 50 mm sandwich panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where effects of wall and ceiling panel thickness, and presence of a unit toilet on FSTL are investigated. It is found that the effect of unit toilet on FSTL is at most 1 dB. From the comparison of FSTL for panels of the same thickness of 50 mm, it is observed that panel having inside air cavity of 10 mm shows higher STL than that of the panel without air cavity. Comparison of FSTL for panels of 50 mm and 25 mm thickness shows that dependency on surface density predicted by mass law is not observed. The sandwich panels act as a mass-spring system, which shows a resonant mode that cannot be explained by the mass law. It is also found that STL from laboratory test is higher than FSTL by 5- 10 dB, which can be explained by flanking structure-borne noise transmission path such as ceiling, floor and corridor-facing wall.

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (천장속 공간을 공유하는 매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-Seop;Lee, Keun-Hee;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.956-960
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so fu. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF