DOI QR코드

DOI QR Code

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials

석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구

  • 하주연 (한국산업기술시험원 재료기술센터) ;
  • 신현규 (한국산업기술시험원 재료기술센터)
  • Received : 2020.01.17
  • Accepted : 2020.03.05
  • Published : 2020.03.31

Abstract

Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

Keywords

References

  1. Furuya S, Chimed-Ochir O, Takahashi K, David A, Takala J. Global asbestos disaster. Int J Environ Res Public Health 2018;15(5):1000 (https://doi.org/10.3390/ijerph15051000)
  2. International Labor Organization(ILO). Encyclopaedia of occupational health and safety. 4th ed. vol II. Geneva, International Labour Office, 1998. p.138-145
  3. Jung SH, Cha JS, Kim SM, Lee WS, Lim HJ, Kim HW. Evaluating the efficiency of an asbestos stabilizer on ceiling tiles and the characteristics of the released asbestos fibers. J Hazard Mater 2015;300:378-386 (https://doi.org/10.1016/j.jhazmat.2015.07.021)
  4. Ki YH, Kim JM, Roh YM, Chung L, Kim YS, Sim SH. A survey for some asbestos containing products in Korea. J Environ Hlth Sci 2008;34(1):108-115 (https://doi.org/10.5668/JEHS.2008.34.1.108)
  5. Kim CK, Ha KT, Kang MH, Chung SN, Kim JS, Kim GY, Chung JH, Eo SM, Jung K. A study on the efficiency test of asbestos stabilizers. J Korean Soc Environ Eng 2018;40(7):277-281 (https://doi.org/10.4491/KSEE.2018.40.7.277)
  6. Kim HK, Chon YW, Roh YM, Hong SH, Kim, CN, Lee IM. Investigation and risk assessment of asbestoscontaining materials used in buildings. J Korean Soc Environ Hyg 2018;29(1):35-42 (http://dx.doi.org/10.15269/JKSOEH.2018.28.1.35)
  7. Kwon JW. Evaluation of quality management of domestic asbestos survey and monitoring service providers. J Korean Soc Environ Hyg 2019;29(2):217-225 (http://dx.doi.org/10.15269/JKSOEH.2019.29.2.217)
  8. Lee RJ, Van Orden DR. Airborne asbestos in buildings. Regul Toxicol Pharmacol 2008;50(2):218-225 (https://doi.org/10.1016/j.yrtph.2007.10.005)
  9. Lim HJ, Lim JY, Jung HS, Lee JY, Lee WS. Study on the introduction of the efficiency test of asbestos stabilizers on the spray-applied ACBM. J Odor Indoor Environ 2012;9(4):345-353
  10. Ministry of Employment and Labor(MoEL). Asbestos Safety Management Act(MoEL Public Notice No. 16272).; 2020
  11. Shin HG, Choi YK, Jeon BR, Ha, JY. A study of penetration depth into ceiling materials containing asbestos according to dilution rate of scattering prevention agent. J Korean Soc Occup Environ Hyg 2015; 25(1):82-88 (http://dx.doi.org/10.15269/JKSOEH.2015.25.1.82)
  12. Shin HG, Choi YK, Jeon BR, Ha, JY, Seon YS, Park WM. A study of asbestos stabilizer treatment considering the actual environment of ceiling materials. J Korean Soc Occup Environ Hyg 2016;26(2):139-146 (http://dx.doi.org/10.15269/JKSOEH.2016.26.2.139)
  13. Song TH, Park JS, Shin HG. A study on penetration effect of penetrating hardener for prevention of scattering of asbestos building materials. J Rec Const Resources 2018;6(4):324-330 (https://doi.org/10.14190/JRCR.2018.6.4.324)
  14. Spasiano D, Pirozzi F. Treatments of asbestos containing wastes. J Environ Manage 2018;204:82-91 (https://doi.org/10.1016/j.jenvman.2017.08.038)
  15. Yoon YR, Kwak KM, Choi YY, Youn KW, Bahk JW, Kang DM, Paek DM. The Asbestos Ban in Korea from a Grassroots Perspective: Why Did It Occur?. Int J Environ Res Public Health 2018;15(2):19 (https://doi.org/10.3390/ijerph15020198)