Abstract
Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.
Keywords
Asbestos; asbestos stabilizer; ceiling materials; durability assessment; humidity;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Furuya S, Chimed-Ochir O, Takahashi K, David A, Takala J. Global asbestos disaster. Int J Environ Res Public Health 2018;15(5):1000 (https://doi.org/10.3390/ijerph15051000)   DOI
2 International Labor Organization(ILO). Encyclopaedia of occupational health and safety. 4th ed. vol II. Geneva, International Labour Office, 1998. p.138-145
3 Jung SH, Cha JS, Kim SM, Lee WS, Lim HJ, Kim HW. Evaluating the efficiency of an asbestos stabilizer on ceiling tiles and the characteristics of the released asbestos fibers. J Hazard Mater 2015;300:378-386 (https://doi.org/10.1016/j.jhazmat.2015.07.021)   DOI
4 Ki YH, Kim JM, Roh YM, Chung L, Kim YS, Sim SH. A survey for some asbestos containing products in Korea. J Environ Hlth Sci 2008;34(1):108-115 (https://doi.org/10.5668/JEHS.2008.34.1.108)
5 Kim CK, Ha KT, Kang MH, Chung SN, Kim JS, Kim GY, Chung JH, Eo SM, Jung K. A study on the efficiency test of asbestos stabilizers. J Korean Soc Environ Eng 2018;40(7):277-281 (https://doi.org/10.4491/KSEE.2018.40.7.277)   DOI
6 Kim HK, Chon YW, Roh YM, Hong SH, Kim, CN, Lee IM. Investigation and risk assessment of asbestoscontaining materials used in buildings. J Korean Soc Environ Hyg 2018;29(1):35-42 (http://dx.doi.org/10.15269/JKSOEH.2018.28.1.35)
7 Kwon JW. Evaluation of quality management of domestic asbestos survey and monitoring service providers. J Korean Soc Environ Hyg 2019;29(2):217-225 (http://dx.doi.org/10.15269/JKSOEH.2019.29.2.217)
8 Lee RJ, Van Orden DR. Airborne asbestos in buildings. Regul Toxicol Pharmacol 2008;50(2):218-225 (https://doi.org/10.1016/j.yrtph.2007.10.005)   DOI
9 Lim HJ, Lim JY, Jung HS, Lee JY, Lee WS. Study on the introduction of the efficiency test of asbestos stabilizers on the spray-applied ACBM. J Odor Indoor Environ 2012;9(4):345-353
10 Ministry of Employment and Labor(MoEL). Asbestos Safety Management Act(MoEL Public Notice No. 16272).; 2020
11 Shin HG, Choi YK, Jeon BR, Ha, JY. A study of penetration depth into ceiling materials containing asbestos according to dilution rate of scattering prevention agent. J Korean Soc Occup Environ Hyg 2015; 25(1):82-88 (http://dx.doi.org/10.15269/JKSOEH.2015.25.1.82)   DOI
12 Shin HG, Choi YK, Jeon BR, Ha, JY, Seon YS, Park WM. A study of asbestos stabilizer treatment considering the actual environment of ceiling materials. J Korean Soc Occup Environ Hyg 2016;26(2):139-146 (http://dx.doi.org/10.15269/JKSOEH.2016.26.2.139)   DOI
13 Song TH, Park JS, Shin HG. A study on penetration effect of penetrating hardener for prevention of scattering of asbestos building materials. J Rec Const Resources 2018;6(4):324-330 (https://doi.org/10.14190/JRCR.2018.6.4.324)
14 Spasiano D, Pirozzi F. Treatments of asbestos containing wastes. J Environ Manage 2018;204:82-91 (https://doi.org/10.1016/j.jenvman.2017.08.038)   DOI
15 Yoon YR, Kwak KM, Choi YY, Youn KW, Bahk JW, Kang DM, Paek DM. The Asbestos Ban in Korea from a Grassroots Perspective: Why Did It Occur?. Int J Environ Res Public Health 2018;15(2):19 (https://doi.org/10.3390/ijerph15020198)