• Title/Summary/Keyword: catheter

Search Result 1,109, Processing Time 0.022 seconds

Two Cases of esophageal foreign body removal using Fogarty catheter (Fogarty 카테터를 이용한 식도 이물(바둑알) 제거 2예)

  • 박시내;박경호;박준욱;여상원;조승호
    • Korean Journal of Bronchoesophagology
    • /
    • v.9 no.1
    • /
    • pp.79-82
    • /
    • 2003
  • Unintentional foreign body ingestion is common in children, and coins are the most common foreign body ingested. Foreign body remaining in the esophagus may be associated with mucosal ulceration or esophageal obstruction and can potentially lead to significant morbidity and even death. Removal of esophageal foreign body is therefore generally recommended. Several methods are utilized including esophagoscopy in operating room, flexible endoscopy in out patient setting, fluoroscopic Foley catheter technique, and advancement using bougienage. We report two cases of esophageal foreign body(paduk stone) which were hard to be removed by usual esophagoscopic removal. Successful removal was accomplished with the aid of Fogarty catheter under the general anesthesia.

  • PDF

The Optical Design of Miniaturized Microscope Objective for CARS Imaging Catheter with Fiber Bundle

  • Rim, Cheon-Seog
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.424-430
    • /
    • 2010
  • In coherent anti-Stokes Raman scattering (CARS) microscopy reported until now, conventional microscope objectives are used, so that they are limited for introduction into a living body. Gradient-index (GRIN) rod lenses might be a solution for miniaturized microscope objectives for in-vivo CARS microscopy. However, due to the inherent large amount of chromatic aberration, GRIN rod lenses cannot be utilized for this purpose. CARS imaging catheter, composed of miniaturized microscope objective and fiber bundle, can be introduced into a living body for minimally invasive diagnosis. In order to design the catheter, we have to first investigate design requirements. And then, the optical design is processed with design strategies and intensive computing power to achieve the design requirements. We report the miniaturized objective lens system with diffraction-limited performance and completely corrected chromatic aberrations for an in-vivo CARS imaging catheter.

Fracture of an Implantable Central Catheter Due to Pinch Off Syndrome (Pinch off 증후군에 의한 피하매몰형 중심정맥도관의 절단)

  • Yun, Ju-Sik;Oh, Sang-Gi;Song, Sang-Yun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.504-507
    • /
    • 2008
  • Implantable central venous catheters (Chemoport) are increasingly being used for vascular access, parenteral nutrition and administering chemotherapeutic agents. As with most invasive procedures, central venous catheterization is associated with numerous potential complications such as infection, thoromboembolism and occlusion. A rare but serous complication is the catheter fracture. We present here three cases of catheter fracture as a consequence of Pinch off syndrome, and we include a review of the relevant literature.

A Study on Performance-Analysis and Control of the Active Catheter (작동형 내시경의 성능 해석 및 제어에 관한 연구)

  • Cheong, J.P.;Kim, J.H.;Lee, J.M.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.556-561
    • /
    • 2000
  • This paper deals with the control of an active bending actuator fur a catheter. The bending actuator with 40mm in length utilizes three zigzag SMA (shape memory alloy) springs which are equally located in the circumference between inner $({\phi}2.5 mm)$ and outer $({\phi}3.0mm)$ tube. It is purposed on realization of desired bending angle $(90^{\circ})$ and direction $(360^{\circ})$. It is also installed in front of the catheter and used to guide a path at extremely bent or branched blood vessel. The performance-analysis of the bending actuator are investigated fur the purpose of optimizing the control of the bending actuator. The analog joy stick is used to command a bending angle and direction for the fast and accurate response. According to the commands of the joy stick, tensile force of each SMA spring is computed and obtained by controlling the temperature of each SMA spring using PWM (pulse width modulation) of supplied electric power.

  • PDF

An Inextensible Wire-shaped Deformation Model for Catheter Simulation (카테터의 거동을 시뮬레이션 하기 위한 고정된 길이를 유지하는 실 형상의 변형체 모델)

  • Han, Hyehyun;Lee, Doo Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.610-614
    • /
    • 2016
  • This paper proposes an inextensible wire-shaped deformation model to simulate catheter behavior. The wire-shaped model consists of serially-connected mass points and massless rigid links. Torsional springs and dampers are employed to accommodate bending. Deformation is computed by updating the rotation angles from the global coordinates while maintaining the fixed length condition. Equations of motion is derived from double pendulum motion. Spring constant is computed using strain energy and potential energy stored in a torsional spring to reflect material property. Simulation is conducted to show deformation of wire model while maintaining inextensibility condition and including material properties. The proposed method guarantees inextensible constraint in the catheter simulation.

Malposition of Epidural Catheter in Cancer Pain Control (암성환자 제통시 발생한 경막외 카테터의 위치이상 -증례 보고-)

  • Ahn, Yong-Wook;Lee, Tae-Hyeon;Roh, Woon-Seok;Kim, Bong-Il;Cho, Soung-Kyung;Lee, Sang-Hwa
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.378-382
    • /
    • 1995
  • Continuous epidural blockade has been used widely for providing anesthesia and analgesia. But many kinds of unusual complications have been reported such as: kinking, knotting, shearing, abnormal positions of catheter, etc. We experienced a case of malposition of the catheter which pass out the epidural space through the intervertebral foramen in a 33-year-old cancer patient. We confirmed it by epidurogram.

  • PDF

Epidural Catheter Malposition in a Failed Epidural Anesthesia Confirmed by Computed Tomography

  • Lee, Se-Jin;Kim, Sang-Ho;Park, Sun-Young;Kim, Mun-Gyu;Jung, Bo-Il;Ok, Si-Young
    • The Korean Journal of Pain
    • /
    • v.24 no.1
    • /
    • pp.44-47
    • /
    • 2011
  • We report a case of failed epidural anesthesia despite successful identification of the epidural space, loss of resistance technique, hanging drop method and drip infusion. This case evaluated the use of computed tomography to confirm epidural catheter position, which showed the catheter accidentally positioned at the T2 lamina. Because epidural anesthesia can even after successful procedure using standardized techniques such as loss of resistance, we recommend performing the procedure under fluoroscopic guidance to improve success rate and patient safety.

Successful Treatment of Catheter Related Blood Stream Infection By Millerozyma farinosa with Micafungin: A Case Report

  • Hong, Sun In;Suh, Young Sun;Kim, Hyun-Ok;Bae, In-Gyu;Shin, Jong Hee;Cho, Oh-Hyun
    • Infection and chemotherapy
    • /
    • v.50 no.4
    • /
    • pp.362-366
    • /
    • 2018
  • Millerozyma farinosa (formerly Pichia farinosa) is halotolerant yeast mainly found in food and ubiquitous in the environment. It was a rare yeast pathogen, but it has recently emerged as a cause of fungemia in immunocompromised patients. Optimal therapy for invasive fungal infection by this pathogen remains unclear. We report a case of catheter related blood stream infection caused by M. farinosa in a 71-year-old patient who recovered successfully after removal of the central venous catheter and treatment with micafungin.

Removal of a Left Upper Lobar Bronchial Foreign Body Using Fogarty Catheter and Rigid Bronchoscope

  • Woo, Hyunjun;Kim, Seo Young;Kwon, Seong Keun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.1
    • /
    • pp.37-41
    • /
    • 2022
  • Airway foreign body aspiration in children can lead to accidental death, due to the foreign body itself or the removal procedure. Depending on its location, removal of the foreign body can be challenging. Here, we present a case of successful removal of a foreign body from the left upper lobar bronchus via ventilating bronchoscopy with a rigid bronchoscope and Fogarty arterial embolectomy catheter. Tracheobronchial foreign bodies in locations that are difficult to reach with forceps, due to an acute angle or the small diameter of the pediatric bronchial tree, can be effectively removed with a Fogarty arterial embolectomy catheter.

Shape Prediction Method for Electromagnet-Embedded Soft Catheter Robot (전자석 내장형 소프트 카테터 로봇 형상 예측 방법)

  • Sanghyun Lee;Donghoon Son
    • The Journal of Korea Robotics Society
    • /
    • v.19 no.1
    • /
    • pp.39-44
    • /
    • 2024
  • This study introduces a novel method for predicting the shape of soft catheter robots embedded with electromagnets. As an advancement in the realm of soft robotics, these catheter robots are crafted from flexible and pliable materials, ensuring enhanced safety and adaptability during interactions with human tissues. Given the pivotal role of catheters in minimally invasive surgeries (MIS), our design stands out by facilitating active control over the orientation and intensity of the inbuilt electromagnets. This ensures precise targeting and manipulation of the catheter segments. The research encompasses a comprehensive breakdown of the magnetic modeling, tracking algorithms, experimental layout, and analytical techniques. Both simulation and experimental results validate the efficacy of our method, underscoring its potential to augment accuracy in MIS and revolutionize healthcare-oriented soft robotics.