Two Cases of esophageal foreign body removal using Fogarty catheter

Fogarty 카테터를 이용한 식도 이물(바둑알) 제거 2예

  • 박시내 (가톨릭대학교 의과대학 이비인후과학 교실) ;
  • 박경호 (가톨릭대학교 의과대학 이비인후과학 교실) ;
  • 박준욱 (가톨릭대학교 의과대학 이비인후과학 교실) ;
  • 여상원 (가톨릭대학교 의과대학 이비인후과학 교실) ;
  • 조승호 (가톨릭대학교 의과대학 이비인후과학 교실)
  • Published : 2003.06.01

Abstract

Unintentional foreign body ingestion is common in children, and coins are the most common foreign body ingested. Foreign body remaining in the esophagus may be associated with mucosal ulceration or esophageal obstruction and can potentially lead to significant morbidity and even death. Removal of esophageal foreign body is therefore generally recommended. Several methods are utilized including esophagoscopy in operating room, flexible endoscopy in out patient setting, fluoroscopic Foley catheter technique, and advancement using bougienage. We report two cases of esophageal foreign body(paduk stone) which were hard to be removed by usual esophagoscopic removal. Successful removal was accomplished with the aid of Fogarty catheter under the general anesthesia.

Keywords