• Title/Summary/Keyword: carrier head

Search Result 39, Processing Time 0.027 seconds

Bow hull-form optimization in waves of a 66,000 DWT bulk carrier

  • Yu, Jin-Won;Lee, Cheol-Min;Lee, Inwon;Choi, Jung-Eun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.5
    • /
    • pp.499-508
    • /
    • 2017
  • This paper uses optimization techniques to obtain bow hull form of a 66,000 DWT bulk carrier in calm water and in waves. Parametric modification functions of SAC and section shape of DLWL are used for hull form variation. Multi-objective functions are applied to minimize the wave-making resistance in calm water and added resistance in regular head wave of ${\lambda}/L=0.5$. WAVIS version 1.3 is used to obtain wave-making resistance. The modified Fujii and Takahashi's formula is applied to obtain the added resistance in short wave. The PSO algorithm is employed for the optimization technique. The resistance and motion characteristics in calm water and regular and irregular head waves of the three hull forms are compared. It has been shown that the optimal brings 13.2% reduction in the wave-making resistance and 13.8% reduction in the added resistance at ${\lambda}/L=0.5$; and the mean added resistance reduces by 9.5% at sea state 5.

Shape Control and Characterization of One-dimensional ZnO Nanostructures through the Synthesis Procedure (합성절차에 따른 1차원 ZnO 나노구조의 형태조절과 특성평가)

  • Kong, Bo-Hyun;Park, Tae-Eun;Cho, Hyung-Koun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.13-17
    • /
    • 2006
  • The one-dimensional ZnO nanostructures prepared through thermal evaporation under various cooling down procedures by changing the flow rates of the carrier gas and the reactive gas were investigated. The nanorod structures were changed into the nanonail types with a broad head through the reduction of the flow rate of the carrier gas. The decrease of the reactive gas reduced the length of the nail heads due to the limited mass transport of reactive gas. The intensity ratio of the ultraviolet emission/green emission of photoluminescence was proportional to the length of the broad head showing a larger surface area. The vertically aligned nanostructures were grown along the [0001] direction of ZnO regardless of the aligned directions. The crystal direction of the nanostructures was determined by that of the initial ZnO crystal.

Dynamic Research of a Potential Carrier for Hydrophobic Compound Model Pyrene Using Amphiphilic Peptide EYK

  • Wang, Liang;Zhao, Xiao-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.620-624
    • /
    • 2011
  • In recent years, the study of self-assembly peptide used in drug delivery system has been attracted great interest from scientists. In the category are self-assembly peptides in the structure either with one hydrophobic surface and another hydrophilic or a hydrophobic head and a hydrophilic tail. Here, we focus on a novel designed peptide EYK with double amphiphilic surfaces, investigating on the capability of peptide as a carrier for hydrophobic compound model pyrene. The fluorescence data presented the dynamic process of the transfer, showing that the pyrene was in the crystalline form in peptide solution, and molecularly migrated from its peptide encapsulations into the membrane bilayers when the peptide-pyrene suspension was mixed with liposome vesicles. The results indicated that the peptide EYK could stabilize hydrophobic pyrene in aqueous solution and delivered it into EPC liposome as a potential carrier.

A Study on Pressure Distribution for Uniform Polishing of Sapphire Substrate

  • Park, Chul jin;Jeong, Haedo;Lee, Sangjik;Kim, Doyeon;Kim, Hyoungjae
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.61-66
    • /
    • 2016
  • Total thickness variation (TTV), BOW, and surface roughness are essential characteristics for high quality sapphire substrates. Many researchers have attempted to increase removal rate by controlling the key process parameters like pressure and velocity owing to the high cost of consumables in sapphire chemical mechanical polishing (CMP). In case of the pressure approach, increased pressure owing to higher deviation of pressure over the wafer leads to significant degradation of the TTV. In this study, the authors focused on reducing TTV under the high-pressure conditions. When the production equipment polishes multiple wafers attached on a carrier, higher loads seem to be concentrated around the leading edge of the head; this occurs because of frictional force generated by the combination of table rotation and the height of the gimbal of the polishing head. We believe the skewed pressure distribution during polishing to be the main reason of within-wafer non-uniformity (WIWNU). The insertion of a hub ring between the polishing head and substrate carrier helped reduce the pressure deviation. Adjusting the location of the hub ring enables tuning of the pressure distribution. The results indicated that the position of the hub ring strongly affected the removal profile, which confirmed that the position of the hub ring changes the pressure distribution. Furthermore, we analyzed the deformation of the head via finite element method (FEM) to verify the pressure non-uniformity over the contact area Based on experiment and FEM results, we determined the optimal position of hub ring for achieving uniform polishing of the substrate.

Relationship between Stress Gene Polymorphisms and Litter Size by AI in Pigs

  • Jin, H.J.;Kim, I.C.;Wee, M.S.;Yeon, S.H.;Kim, C.D.;Lee, S.S.;Cho, C.Y.;Cho, S.R.;Son, D.S.;Park, C.K.;Li, Z.D.
    • Journal of Embryo Transfer
    • /
    • v.22 no.4
    • /
    • pp.257-263
    • /
    • 2007
  • This study was performed to investigate the relationship between PSS-HSP70 gene polymorphism and artificial insemination (AI) reproductivity in the pigs. The RFLP polymorphism of PSS and the SSCP polymorphisms of HSP70 K1, K3 and K4 PCR product were detected different patterns. In the experiment for AI of fresh semen, spring and fall season showed higher litter size born of 10.89 head than 10.47 head of summer season. Landrace was showed higher litter size of 9.96 head than that of Duroc and Yorkshire (p<0.05). Stress relating PSS and HSP70 polymorphism of PSS-Normal, HSP70 K1-BB, K3-AB, K4-AA showd a highest litter size born of 10.97 head and litter size born alive of 10.69 head than that of the other polymorphisms(p<0.05). In the experiment for AI of frozen semen, effects of season and pig breeds were not showed for litter size born. The stress relating polymorphism of PSS-Carrier, HSP70 K1-BB, K3-BB, K4-AB showed highest litter size born of 11.29 head and litter size born alive of 10.82 head and PSS-Normal, HSP70 K1-BB, K3-AB, K4-AA showed the lowest litter size born of 8.48 head and litter size born alive of 7.33 head than that of the other polymorphisms(p<0.05). These results suggest that AI litter size born for the stress of forzen thawed semen may be affected by PSS and HSP70 polymorphism in pigs.

The effects of body posture by using Baby Carrier in different ways (아기띠 착용 방법이 신체정렬에 미치는 영향)

  • Kim, Kyoung;Yun, Ki Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.193-200
    • /
    • 2013
  • PURPOSE: The purpose of this study was to find out variations in body posture by using the baby carrier at the front side and back side. METHODS: Thirty two healthy and young female who will bring up infants and had no musculoskeletal disorders of neck, lumbar and low limb were recruited for this study. They were each marked about ears of tragus, cervical 7th, acromion anterior end, anterior superior iliac spine, posterior superior iliac spine, greater trochanter and lateral malleolus as landmarks to measure variations of body posture when they carry infants at the front side and back side. Landmarks were regarded as the creteria in order to measure NeckFlexion angle(NF), Foreward shoulder angle(FSA), Pelvic tilt(PT), Sway angle(SA), Head displacement(HD) and Scapular displacement(SD). Variations in body posture were measured from the neutral position to the front and back side by using Image J. RESULTS: There were significance level (p<.05) in NF, PT, SA, HD and SD except for FSA in two different side. CONCLUSION: The results of this study indicate that each of the using ways of baby carrier for baby care was influenced postural responses of young women. therefore, it could be considered to apply to women who have abnormal body posture in order to minimize musculoskeletal disorders.

CFD Application for Prediction of Ship Added Resistance in Waves

  • Kim, Byung-Soo;Kim, Yonghwan
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.3
    • /
    • pp.135-145
    • /
    • 2018
  • This paper deals with the added resistance of a ship in waves using computational fluid dynamics (CFD). The ship added resistance is one of the key considerations in the design of energy-efficient ship. In this study, the added resistance of a LNG carrier in head waves is computed using a CFD code to consider the nonlinearity and the viscous effects. The unsteady Reynolds Averaged Navier-Stokes equation (RANS) is numerically solved and the volume of fluid (VOF) approach is used to simulate the free surface flows. The length of incident wave varies from half the ship length to twice the ship length. To investigate the nonlinearity effect, both the linear wave condition and the nonlinear wave condition are considered. The heave and pitch motions are calculated along with the added resistance, and the wave contours are obtained. Grid convergence test is conducted thoroughly to achieve the converged motion and resistance values. The calculated results are compared and validated with experimental data.

Numerical Modeling for GaN Deposition by MOCVD: Effects of the Gas Inlet

  • Yang, Wonkyun;Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.23 no.3
    • /
    • pp.139-144
    • /
    • 2014
  • GaN deposition equipment and processes for the fabrication of white LEDs (Light Emitting Diode) using MOCVD (Metal Organic Chemical Vapor Deposition) were numerically modeled to analyze the effects of a reactive gas introduction strategy. The source gases, TMGa and $NH_3$, were injected from a shower head at the top of the chamber; the carrier gases, $H_2$ or $N_2$, were introduced using two types of injection structures: vertical and horizontal. Wafers sat on the holder at a radial distance between 100 mm and 150 mm. The non-uniformity of the deposition rates for vertical and horizontal injection were 4.3% and 3.1%, respectively. In the case of using $H_2$ as a carrier gas instead of $N_2$, the uniform deposition zone was increased by 20%.

A Study on the Efficiency of Clinical Practice for Nursing Education in the Junior College of Nursing in Korea (전문대학 간호과의 임상 실험 효율화를 위한 연구)

  • Lee, Kun-Ja;Kim, Myung-Soon;Yang, Young Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.77-108
    • /
    • 1989
  • The purpose of this study was to find out the present condition of clinical practice and to develop a scheme on the efficiency of clinical practice for nursing education in junior college of nursing in korea. This study was conducted by 2 sections. Ist section was to find out the present condition of clinical practice to 42 directors of nursing collegd and data were collected July 8 to September 30, 1988. 2nd section wat to develop a scheme on the efficiency of clinical practice for nursing education and subjects were nursing professors 258: and clinical nurses 223 in 42 junior nursing colleges their clinical settings in korea. So total subjects were 481. Data were collected july 8, 1988 to June 30, 1988 and were analysed to get the mean, standand deviation, frequency, percentage, t-test, x-test used by SPSS - pc. Major findings were as follows: 1. The present condition of clinical education in junior college of nursing in Korea. 1) 32 colleges (76.2%) were managed by a-yeas system. 2) 25 colleges (59.5%) were performed by individual practice for each subject. 3) 4 weeks interval between class education and clinical education was a major type among total colleges(36.6%, J5 colleges) 4) 30 colleges (71.4%) provided clinical education for all subjects that should be practiced. Nursing administration wes not practiced in 5 colleges (41.9%) among the remainder(12 colleges). The main cause that all practice subjects were not practiced was the lack or absence of suitable clinical settings(8 colleges. 66.7%) 5) 18 colleges (42.9%) responded that a clinical educator was, subject-charged professor. 6) 12 colleges (29.3%) responded that a clinical instructor was in charge of 6~10 students. 7) The evaluation ration ratio(professor to head nurse) by each evaluator was mostly 50% to 50 % and 60% to 40%, respectively 11 colleges(27.5%) The most common evaluation methods were evaluation by head nures, report, presence, conference (11 colleges, 27.5%) 8) The field carrier of professor was mostly 2 years (79 persons, 20.7%) and mean was 3.2 years. The education carrier of a professor was mostly over than 6 years (261 persons, 66.4%) and mean was 9.2 years. The charge hours per-week of a professor were mostly 16-18 hours (16 persons, 131.8%) 9) 34 colleges (82.9%) approved that clinical practice hour was class hour and 18 colleges (43.9 %) counted that 2 hours of clinical education equaled 1 hour of class education. 2. A study 'on the efficiency of clinical practice for nursing education. L) general characteristics of subjects were as follows: kung-sang province (145 persons, 30.5%), 30-34 years (190 persons, 39.8%), graduated degree (245 persons, 51.5%), 6-10 years of carrier (199 persons, 41.4%) were the majority. 2) suitable clinical setting was responded the systematic ward with responsible clinical educator by 210 persons(43.8%) The response by working field of subjects showed a significant difference (p< 0.01) 3) 259 subjects (54.0%) responded that the desirable qualfication of clinical instructor was 3-5 years of clinical experience with master degree or higher. 4) The mean score of desirable quality degree of clinical instructor was 3.43 professors, score (3.54) was significantly higher than clinical nurses' (3.28) (p<0.01) 412 subjects (86.0%) responded that the insufficient guality of instructor was improved by continuing to seek more new information in reference. 5) 196 subjects (41.4%) responded that desirable qualification of head nurse was more than 2 years of head position among 5 years of clinical experience. The response by working' field of subjects showed a significant difference (p<0.05) 6) The mean score of desirable quality degree of head nurse was 3.18 Clinical nurses' score(3.38) was significantly higher than professors' (3.01) (p<0.01) 419 subjects (87.8%) responded that the insufficient of head nurse was improved by continuing relationship with instructor and being responsible from planing of clinical education. 7) The mean score of performance level of the desirable clinical education guide incollege was 2.91 Professors' score (2.96) was significantly higher than clinical nurses' (2.84) (p<0.01) 340 subjects (71.1%) responded that the possible resolution for poor performance was the more specified syllabus of clinical education and the satisfiable orientation for students. 8) The mean score of performance level of the desirable clinical education guide in hospital was 3.03 9) 141 subjects (29.6%) responded that the desirable clinical evaluator was the group of professor, head nurse, staff nurse. Response by working field of subjects was a significant difference (p< 0.05) 10) The mean score of performance level of the evaluation content needed in clinical education was 3.50 Clinical nurses' score (3.56) was significantly higher than professors' (3.45) (p<0.01) 11) 433 subjects (90.2%) responded that6 desirable evaluation method for clinical education was the presence. 12) The mean score of performance level about how personal difference among clinical educators was minimized was 2.89 and response by working field of subjects was not significant. The cause of poor performance was too much workload at clinical settings and too many students st colleges by 386 subjects (81.1%).

  • PDF