• Title/Summary/Keyword: cardiovascular system

Search Result 1,182, Processing Time 0.025 seconds

Ascending Aortic Rupture in a Young Woman with Loeys-Dietz Syndrome: The First Case Report in Korea (Loeys-Dietz 증후군으로 진단된 젊은 여자 환자의 상행 대동맥 파열: 국내 첫 번째 증례 보고)

  • Kim, Hwan-Wook;Lee, Taek-Yeon;Moon, Duk-Hwan;Choo, Suk-Jung;Chung, Cheal-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.639-644
    • /
    • 2009
  • Characterized by unique phenotypic features such as aortic aneurysm/dissection, hypertelorism, bifid uvula/cleft palate and generalized tortuosity in the arterial system, Loeys-Dietz syndrome is a newly described aggressive connective tissue disorder associated with mutation in the gene encoding transforming growth factor-$\beta$ receptor type I or type II. Some phenotypic manifestations of Loeys-Dietz syndrome overlap with those of Marfan syndrome or Ehlers-Danlos syndrome type IV. However, due to its more malignant pathophysiologic nature, physicians should be alert to Loeys-Dietz syndrome. High suspicion, early diagnosis, preventive surgery and serial imaging assessments are warranted for optimal management of Loeys-Dietz syndrome. We present here a case of a young patient with Loeys-Dietz syndrome who had aortic rupture, bifid uvula and hypertelorism. We also present a review of the medical literature.

Application of Veno-venoarterial Extracorporeal Membrane Oxygenation in Multitrauma Patient with ARDS - A case report - (다발성 외상으로 유발된 급성호흡부전증후군 환자에서 정맥-정맥동맥 체외막 산화기(ECMO)의 적용 - 1예 보고 -)

  • Lee, Sung Jun;Chee, Hyun Keun;Hwang, Jae Joon;Kim, Jun Seok;Lee, Song Am;Kim, Jin Sik
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.104-107
    • /
    • 2010
  • Acute respiratory distress syndrome (ARDS) is difficult to treat and it is often fatal. If the medical treatment for ARDS is not effective, then extracorporeal membrane oxygenation (ECMO) can be applied to the patient. A 22-year-old female who suffered multiple traumatic injuries due to a car accident presented with acute respiratory distress syndrome. Veinarterial extracorporeal membrane oxygenation (VA ECMO) was started to treat her respiratory failure. With the VA ECMO, the systemic oxygen saturation remained at only 84%, and so the ECMO system was switched to V-VA ECMO via an additional venous outflow through the right jugular vein to increase both the systemic and pulmonary oxygen saturation. After conversion to the V-VA type ECMO, the systemic oxygen saturation increased to 94% and the partial pressure of oxygen ($PaO_2$) increased to 65 mmHg. We report here on a successful case of ECMO conversion from the VA type to the V-VA type in a patient with severely hypoxic respiratory failure.

The Effects of 12-Week Training for the Physical Fitness and Cardiovascular Factors to Examine Physical Fitness on Firefighters Test-Taker (소방공무원 수험생의 체력검정을 위한 12주간 훈련이 체력요인, 심혈관계요인에 미치는 영향)

  • Lim, Youn-Sub;Park, Jin-Hong;Kim, Jong-Hyuck;Kim, In-Dong;Kim, Jae-Joong;Park, Jeong-Beom;Lee, Chae-Mun
    • Journal of Industrial Convergence
    • /
    • v.19 no.4
    • /
    • pp.111-126
    • /
    • 2021
  • The purpose of this study was to investigate the effects of 12-week training on changes in physical fitness and cardiovascular factors for firefighters. For this purpose, 40 men in their 20s and 30s who agreed to participate voluntarily were recruited. They were divided into four groups: the firefighters' physical fitness test training group (hereinafter referred to as PT group), firefighters' physical fitness test and aerobic training group (hereinafter referred to as PT+AR group), firefighters' physical fitness test and both aerobic and anaerobic training group (hereinafter referred to as PT+CO group). Physical fitness factors (grip strength, back muscle strength, seated forward bend, standing long jump, sit-ups, 20-meter shuttle run), cardiovascular factors (total cholesterol, triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, glucose, waist circumference, systolic blood pressure, diastolic blood pressure) and the relationship between Framingham Heart Risk Score and physical/cardiovascular factors were compared and analyzed, and the following conclusions were obtained. Aerobic training, anaerobic training, and combined training, including 12 weeks of firefighter physical examinations, all had positive effects on fitness and cardiovascular factors, which would be an appropriate way for firefighter examinees to improve physical strength and reduce the risk of cardiovascular disease.

Digital Subtraction Technique for Intravenous X-ray Image System (컴퓨터 영상처리 방식을 이용한 정맥내 혈관 조영술 시스템 개발)

  • 이승지;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.109-116
    • /
    • 1981
  • The objective of this research is to develop the hardware and software systenls of the digital intravenous angiographic system. The system will be used in clinical diagnosis of cardiovascular and cerebrovascular diseases. By utilizing computer image processing technique and digital subtraction method, the system can decrease the patient's harzard and expenses in performing intravenous angiography, as compared with conventional angiograms of the arterial injection.

  • PDF

A Study on the Complaints of Physical and Mental Health Problem of University Professors and Officials by C. M. I. (C. M. I에 의한 대학 교직원들의 신체적, 정신적 건강문제 호소에 관한 연구 - 일개 대학교를 주심으로 -)

  • Lee In Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.80-94
    • /
    • 1996
  • This study was to investigated the complaints of physical and mental health problem of professors and officials in H University of Seoul and collected during the period from April 25 to May 31. 1995. The complaints of physical and mental health problem were measured by Cornell Medical Index. The results of this study are as follows: 1. Among the items of physical health problem. respondents showed the highest rate of complaints related to fatigability. and among the items of mental health problem. respondents showed the highest rate of complaints related to inadequacy. 2. Females showed significantly higher rates of complaints related to the musculoskeletal system(p<0.001), fatigability(p<.001). habits(p<.01), inadequacy(p<.05). and tension(p<.001) compared with those of males. Twenties showed significantly higher rates of complaints related to the digestive system(p<.01) compared with those of other age groups. Singles showed significantly higher rates of complaints related to the digestive system(p<.05). inadequacy(p<.01) and depression(p<.001) compared with those of marries. Officals showed significantly higher rates of complaints related to the cardiovascular system(p<.01). digestive system(p<.05), musculoskeletal system(p<.05), and tension(p<. 05) compared with those of professors. Resondents who have irregular eating habits showed significantly higher rates of complaints related to the digestive system(p<.01), musculoskeletal system(p<.05). habits(p<.05). and depression(p<.001) compared with those of respondents who have regular eating habits. Respondents who usually sleep below 6 hours a day showed significantly higher rates of complaints related to the cardiovascular system(p<.01). digestive system(p<.05). musculoskeletal system(p<.01). fatigability(p<.05). habits(p<.01). and tension(p<.05) compared with those of respondents who sleep above 6 hours.

  • PDF

Initial Experience of Robotic Cardiac Surgery (수술로봇을 이용한 심장수술 첫 체험)

  • Cho Sung Woo;Chung Cheol Hyun;Kim Kyoung Sun;Choo Suk Jung;Song Hyung;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.366-370
    • /
    • 2005
  • Background: In general, cardiac surgery has been performed via median sternotomy. During the past decade, improvements in endoscopic equipment and operative techniques have resulted in development of minimally invasive cardiac operation using small incisions. With the advent of a voice controlled camera-holding robotic arm (AESOP 3000, Automated Endoscope System for Optimal Positioning), cardiac surgery entered the robotic age. Material and Method: Between April 2004 and December 2004, a total of seventy eight patients underwent robotic cardiac surgery, of whom sixty four patients underwent robot-assisted minimally invasive cardiac surgery via 5cm right lateral minithoracotomy using voice controlled robotic arm, femoral vessels cannulation, percutaneous internal jugular cannulation, transthoracic aortic cross clamp. Other fourteen patients underwent MIDCAB via internal mammary artery harvesting using AESOP. Result: Robotic cardiac surgery were mitral valve repair in 37 cases, mitral valve replacement in 10 cases, aortic valve replacement in 1 case, MIDCAB in 14 cases, ASD operation in 9 cases, and isolated Maze procedure in 1 case. In mitral operation, mean CPB time was $165.3\pm43.1$ minutes and mean ACC time was $110.4\pm48.2$ minutes. Median length of hospital stay was 6 days (range 3 to 30) in mitral operation, 4 days (range 2 to 7) in MIDCAB, and 4 days (range 2 to 6) in ASD operation. For complications, 3 patients were required by reoperation for bleeding. There was no hospital mortality. Conclusion: Our experience of robot cardiac surgery suggests that many cardiovascular surgeons will be able to perform minimally invasive cardiac operations through small incisions with robot-assisted video-direction. Well-designed studies and close long-term follow-up will be required to analyze the benefits of robot-assisted operation.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

Monitoring of Activated Coagulation Time with Kaolin vs. Celite Activator in Cardiac Surgical Patients with Aprotinin (Aprotinin을 투여한 개심술 환자에서 Kaolin과 Celite Activator를 이용한 Activated Coagulation Time(ACT) 측정의 비교)

  • Kim, Joung-Taek;Sun, Kyung;Lee, Choon-Soo;Baik, Wan-Ki;Cho, Sang-Rock;Kim, Hyun-Tae;Kim, Hea-Sook;Park, Hyun-Hee;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.873-876
    • /
    • 1998
  • Background: High-dose aprotinin has been reported to enhance the anticoagulant effects of heparin during cardiopulmonary bypass ; hence, som authors have advocated reducing the dose of heparin in patients treated with aprotinin. Material and Method: The ACT was measured before, during and after cardiopulmonary bypass, with Hemochron 801 system using two activators of celite(C-ACT) and kaolin(K- ACT) as surface activator. From June, 1996 to February, 1997, 22 adult patients who were scheduled for elective operation were enrolled in this study. Result: The ACT without heparin did not differ between C-ACT and K-ACT. At 30 minutes after anticoagulation with heparin and cardiopulmonary bypass, the average C-ACT was 928${\pm}$400 s; K-ACT was 572${\pm}$159s(p<0.05). After administration of protamine, C-ACT was 137${\pm}$26 s; K-ACT was 139${\pm}$28s, which were not statistically significant. Conclusion: Our results showed that the significant increase in the ACT during heparin- induced anticoagulation in the presence of aprotinin was due to the use of celite as surface activator, rather than due to enhanced anticoagulation of heparin by aprotinin. We conclude that the ACT measured with kaolin provides better monitoring of cardiac surgical patients treated with high dose aprotinin than does the ACT measured with celite. The patients treated with aprotinin should receive the usual doses of heparin.

  • PDF

"A Study on the Health Status of College Students by Cornell Medical Index" (C.M.I.에 의한 일부대학생(一部大學生)들의 건강상태(健康狀態)에 관(關)한 조사연구)

  • Jun, Yoon Byoung
    • Journal of the Korean Society of School Health
    • /
    • v.2 no.1
    • /
    • pp.48-57
    • /
    • 1989
  • To evaluate the college students' health status, the author distributed C.M.I. to 233 college students consisting of 102 males and 131 females who randomly selected from a college in seoul. The conclusion are as follow: 1. The mean of CMI scores for the male students was 32.84 and that for the female students was 43.25. Statistical significant difference was observed between the mean of CMI scores for male students and that for female students. 2. For male students, The CMI mean scores for the day students was 29.46 and for evening students was 35.85. There was no statistical significant difference the day students and that for the evening students. 3. For female students, the mean of CMI scores for day students was 42.40 and that for the evening students was 44.64. But there was no statistical significant difference between the mean CMI scores for the day students and that for the evening students. 4. In both female and male groups, the affirmative response rate of inadequacy, fatigability and eyes and ears are higher than any of the other items. 5. In comparing the CMI items of male students and female students, the significant differences cardiovascular system, musculoskeletal system, skin, nervous system, genitourinary system, fatigability, habits, inadequacy, depression and tension. The mean scores for female students, with the exception of habits, were higher than those for male students. 6. In comparing the CMI items of male day students and male evening students, there was significant difference in the items of the cardiovascular system, digestive tract, skin, genitourinary system, inadequacy, and anger : the mean scores of evening male students were higher than those of day students. 7. In the case of female students, the CMI mean scores of the evening students in the categories eyes and ears, cardiovascular system, digestive tract, musculoskeletal system, skin, genitourinary system, fatigability, inadequacy, depression, anxiety, and sensitivity were higher scores than those of the day students. However, the were no significant difference between both groups except in the cathgory of habits. 8. The frequency rate of neurotic students, who were identified by fukamachi's classification, were 12.5% in the day male students, 18.6% in th evening male students, 13.6% in the day female students, and 18.0% in the evening female students.

  • PDF

Development of a Pulse Wave Velocity Measurement System and Assessment of the System Reproducibility for the Diagnosis of Arteriosclerosis (동맥경화 진단을 위한 맥파전달속도 측정시스템 개발 및 재현성 평가)

  • Lee, Nak-B.;Im, Jae-J.;Park, Young-B.;Jeon, Young-J.
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.112-124
    • /
    • 2005
  • Background: PWV is determined by dividing the distance by the time taken for the pulses traveling between two measuring sites, used as a marker of arterial stiffness and an important indicator for cardiovascular disease. Methods: A PWV measurement system, which offers a non-invasive, simple method of measurement, and simultaneous recording of six signlas(ECG, PCG and four pulse waves from carotid, femoral, radial and dorsalis pedis arteries) was developed. Seventeen healthy subjects with a mean age of 33 years(22 to 52) without any cardiovascular disease were participated for the experiment. Two observers(A and B) performed two consecutive measurements from the same subject in a random order. For the evaluation of stability and accuracy of the PWV measurement system, reproducibility of PWV from between-observer were also evaluated. Results: PWV $values(Mean{\pm}SD)$ measured by A were $7.07{\pm}1.48m/s$, $8.43{\pm}1.14m/s$ , $8.09{\pm}0.98m/s$ for aorta, arm, and leg, respectively. The values obtained from B were $6.76{\pm}1.00m/s$, $7.97{\pm}0.80m/s$, and $7.97{\pm}0.72m/s$ for aorta, arm, and leg, respectively. Between-observer $differences(mean{\pm}SEM)$ from the aorta, arm and leg were $0.14{\pm}0.15m/s$, $0.18{\pm}0.10m/s$ and $0.07{\pm}0.10m/s$. Reproducibility coefficients(2SD) from the aorta, arm, and leg were 0.62m/s, 0.84m/s and 0.86m/s. Correlation coefficients were significantly higher in aortic PWV, 0.93, compared to the coefficients for arm and leg. Coefficient of variance which reflects the reproducibility of the system ranged from $4.4{\sim}5.8%$ in all regional PWV. , Conclusion: Reproducibility of PWV in the study shows that the developed system has reliable and reproducible characteristics. The PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis and results with high reproducibility. Results of the PWV measurement system could contribute to various clinical applications in the future.

  • PDF